Nick Rothbart

Dr. Nick Rothbart


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NRNick Rothbart
Nick Rothbart
OHOlaf Holz
Olaf Holz
RKRembert A Koczulla
Rembert A Koczulla
KSKlaus Schmalz
Klaus Schmalz
HHHeinz-Wilhelm Hübers
Heinz-Wilhelm Hübers
Breath gas analysis is a promising tool for medical research and diagnosis. A particularly powerful technological approach is millimeter-wave/terahertz (mmW/THz) spectroscopy, because it is a very sensitive and highly selective technique. In addition, it offers the potential for compact and affordable sensing systems for wide use. In this work, we demonstrate the capability of a mmW/THz spectrometer for breath analysis. Samples from three volunteers and a sample from ambient air were analyzed with respect to 31 different molecular species. High-resolution absorption spectra were measured by scanning two absorption lines from each species. Out of the 31, a total of 21 species were detected. The results demonstrate the potential of mmW/THz spectroscopy for breath analysis.

28 October 2019 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
NRNick Rothbart
Nick Rothbart
KSKlaus Schmalz
Klaus Schmalz
HHHeinz-Wilhelm Hubers
Heinz-Wilhelm Hubers

27 September 2021 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
DJDivya Jayasankar
Divya Jayasankar
VDVladimir Drakinskiy
Vladimir Drakinskiy
NRNick Rothbart
Nick Rothbart
HRHeiko Richter
Heiko Richter
XLXiang Lü
Xiang Lü
JSJan Stake
Jan Stake
Efficient and compact frequency converters are essential for frequency stabilization of terahertz sources. In this article, we present a ${3.5}$ -THz, ${\times 6}$ -harmonic, integrated Schottky diode mixer operating at room temperature. The designed frequency converter is based on a single-ended, planar Schottky diode with a submicron anode contact area defined on a suspended 2- ${\mu }$ m ultra-thin gallium arsenide substrate. The dc-grounded anode pad was combined with the radio frequency E-plane probe, which resulted in an electrically compact circuit. At $\text{200}$ -MHz intermediate frequency, a mixer conversion loss of about $\text{59}$ dB is measured resulting in a ${40}$ -dB signal-to-noise ratio for phase locking a ${3.5}$ -THz quantum-cascade laser. Using a quasi-static diode model combined with electromagnetic simulations, good agreement with the measured results was obtained. Harmonic frequency converters without the need of cryogenic cooling will help in the realization of highly sensitive space and air-borne heterodyne receivers.

28 June 2022 in Journal of Breath Research
Verified
Journal Article
Open access
NRNick Rothbart
Nick Rothbart
VSVictoria Stanley
Victoria Stanley
RKRembert Koczulla
Rembert Koczulla
IJInga Jarosch
Inga Jarosch
OHOlaf Holz
Olaf Holz
HHHeinz-Wilhelm Hübers
Heinz-Wilhelm Hübers
The analysis of human breath is a very active area of research, driven by the vision of a fast, easy, and non-invasive tool for medical diagnoses at the point of care. Millimeter-wave gas spectroscopy (MMWGS) is a novel, well-suited technique for this application as it provides high sensitivity, specificity and selectivity. Most of all, it offers the perspective of compact low-cost systems to be used in doctors’ offices or hospitals. In this work, we demonstrate the analysis of breath samples acquired in a medical environment using MMWGS and evaluate validity, reliability, as well as limitations and perspectives of the method. To this end, we investigated 28 duplicate samples from chronic obstructive lung disease patients and compared the results to gas chromatography-mass spectrometry (GC-MS). The quantification of the data was conducted using a calibration-free fit model, which describes the data precisely and delivers absolute quantities. For ethanol, acetone, and acetonitrile, the results agree well with the GC-MS measurements and are as reliable as GC-MS. The duplicate samples deviate from the mean values by only 6% to 18%. Detection limits of MMWGS depend strongly on the molecular species. For example, acetonitrile can be traced down to 1.8 × 10−12 mol by the MMWGS system, which is comparable to the GC-MS system. We observed correlations of abundances between formaldehyde and acetaldehyde as well as between acetonitrile and acetaldehyde, which demonstrates the potential of MMWGS for breath research.

3 September 2021 in IEEE Access
Verified
Journal Article
Open access
KSKlaus Schmalz
Klaus Schmalz
NRNick Rothbart
Nick Rothbart
AGAlexandra Gluck
Alexandra Gluck
MEMohamed Hussein Eissa
Mohamed Hussein Eissa
TMThomas Mausolf
Thomas Mausolf
HHHeinz-Wilhelm Hubers
Heinz-Wilhelm Hubers
This paper presents a transmitter (TX) and a receiver (RX) with bowtie-antenna and silicon lens for gas spectroscopy at 222-270 GHz, which are fabricated in IHP's 0.13 μm SiGe BiCMOS technology. The TX and RX use two integrated local oscillators for 222 - 256 GHz and 250 - 270 GHz, which are switched for dual-band operation. Due to its directivity of about 27 dBi, the single integrated bowtie-antenna with silicon lens enables an EIRP of about 25 dBm for the TX, and therefore a considerably higher EIRP for the 2-band TX compared to previously reported systems. The double sideband noise temperature of the RX is 20,000 K (18.5 dB noise figure) as measured by the Y-factor method. Absorption spectroscopy of gaseous methanol is used as a measure for the performance of the gas spectroscopy system with TX- and RX-modules.

29 August 2022 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
AGAlexandra Gluck
Alexandra Gluck
NRNick Rothbart
Nick Rothbart
KSKlaus Schmalz
Klaus Schmalz
HHHeinz-Wilhelm Hubers
Heinz-Wilhelm Hubers
Molecular spectroscopy with THz heterodyne receivers is an important and widely used method for remote sensing of gases in space, in the Earth's and planetary atmospheres, as well as in the coma of comets. For the use on small satellites, compact and light-weight receivers are needed. We have developed an integrated SiGe BiCMOS receiver frontend which is tunable from 225 GHz to 255 GHz and have characterized it for heterodyne spectroscopy. The double-sideband noise temperature is 11 000 K at a local oscillator frequency of 240 GHz and the Allan time is 1 s. With this receiver we successfully performed heterodyne absorption and emission spectroscopy of acetonitrile in laboratory experiments.