Andreas Riedo

Dr. Andreas Riedo

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2012 in Journal of Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
ARAndreas Riedo
Andreas Riedo
ABA. Bieler
A. Bieler
MNM. Neuland
M. Neuland
MTM. Tulej
M. Tulej
PWP. Wurz
P. Wurz

26 June 2013 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
ARAndreas Riedo
Andreas Riedo
MNMaike Neuland
Maike Neuland
SMStefan Meyer
Stefan Meyer
MTMarek Tulej
Marek Tulej
PWPeter Wurz
Peter Wurz
Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.

20 January 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
VGValentine Grimaudo
Valentine Grimaudo
PMPavel Moreno-García
Pavel Moreno-García
ARAndreas Riedo
Andreas Riedo
SMStefan Meyer
Stefan Meyer
MTMarek Tulej
Marek Tulej
PBPeter Broekmann
Peter Broekmann

2 August 2017 in Journal of Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
SMStefan Meyer
Stefan Meyer
ARAndreas Riedo
Andreas Riedo
MNMaike B. Neuland
Maike B. Neuland
MTMarek Tulej
Marek Tulej
PWPeter Wurz
Peter Wurz

1 April 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
ARAndreas Riedo
Andreas Riedo
Marek TulejMarek Tulej
Marek Tulej
URUrs Rohner
Urs Rohner
PWPeter Wurz
Peter Wurz
High-speed detector systems with high dynamic range and pulse width characteristics in the sub-nanosecond regime are mandatory for high resolution and highly sensitive time-of-flight mass spectrometers. Typically, for a reasonable detector area, an impedance-matched anode design is necessary to transmit the registered signal fast and distortion-free from the anode to the signal acquisition system. In this report, a high-speed microstrip multi-anode multichannel plate detector is presented and discussed. The anode consists of four separate active concentric anode segments allowing a simultaneous readout of signal with a dynamic range of about eight orders of magnitude. The impedance matched anode segments show pulse width of about 250 ps, measured at full width at half maximum, and rise time of ∼170 ps, measured with an oscilloscope with a sampling rate of 20 GS/s and 4 GHz analogue bandwidth. The usage of multichannel plates as signal amplifier allowed the design of a lightweight, low power consuming, and compact detector system, suitable, e.g., for the integration into space instrumentation or portable systems where size, weight, and power consumption are limited parameters.

12 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Marek TulejMarek Tulej
Marek Tulej
NLNiels Ligterink
Niels Ligterink
CKCoenraad de Koning
Coenraad de Koning
VRValentine Riedo-Grimaudo
Valentine Riedo-Grimaudo
RLRustam Lukmanov
Rustam Lukmanov
PWPeter Wurz
Peter Wurz
The last decade witnessed considerable progress in the development of laser ablation/ionisation time-of-flight mass spectrometry (LI-TOFMS). The improvement of both the laser ablation ion sources employing femtosecond lasers and the method of ion coupling with the mass analyser led to highly sensitive element and isotope measurements, minimisation of matrix effects, and reduction of various fractionation effects. This improvement of instrumental performance can be attributed to the progress in laser technology and accompanying commercialisation of fs-laser systems, as well as the availability of fast electronics and data acquisition systems. Application of femtosecond laser radiation to ablate the sample causes negligible thermal effects, which in turn allows for improved resolution of chemical surface imaging and depth profiling. Following in the footsteps of its predecessor ns-LIMS, fs-LIMS, which employs fs-laser ablation ion sources, has been developed in the last two decades as an important method of chemical analysis and will continue to improve its performance in subsequent decades. This review discusses the background of fs-laser ablation, overviews the most relevant instrumentation and emphasises their performance figures, and summarizes the studies on several applications, including geochemical, semiconductor, and bio-relevant materials. Improving the chemical analysis is expected by the implementation of laser pulse sequences or pulse shaping methods and shorter laser wavelengths providing current progress in mass resolution achieved in fs-LIMS. In parallel, advancing the methods of data analysis has the potential of making this technique very attractive for 3D chemical analysis with micrometre lateral and sub-micrometre vertical resolution.