Meixiu Sun

Dr. Meixiu Sun

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
CJChenyu Jiang
Chenyu Jiang
MSMeixiu Sun
Meixiu Sun
ZWZhennan Wang
Zhennan Wang
ZCZhuying Chen
Zhuying Chen
XZXiaomeng Zhao
Xiaomeng Zhao
Chuji WangChuji Wang
Chuji Wang
Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests.

23 September 2022 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
XWXin Wei
Xin Wei
QLQingyuan Li
Qingyuan Li
YWYinghua Wu
Yinghua Wu
JLJing Li
Jing Li
GZGuangkuo Zhang
Guangkuo Zhang
YLYingxin Li
Yingxin Li
Background: Lung cancer is one of the most common malignant tumors worldwide. Currently, effective screening methods for early lung cancer are still scarce. Breath analysis provides a promising method for the pre-screening or early screening of lung cancer. Isoprene is a potential and important breath biomarker of lung cancer. Material and Methods: To investigate the clinical value of isoprene for diagnosing lung cancer patients, a cavity ringdown spectroscopy (CRDS) based near-real time, sensitive analysis method of breath isoprene is developed in our lab. In this paper, 92 breath samples from lung cancer patients, 17 breath samples from patients with benign lesions, and 107 breath samples from healthy people were collected. Results: Research indicates that breath isoprene concentration is significantly higher in healthy individuals (221.3±122.2 ppbv) than in patients with lung cancer (112.0±36.6 ppbv) and benign lung lesions (127.9±41.2 ppbv). The result of Receiver Operating Characteristic (ROC) curve suggests that the concentration of isoprene is meaningful for the diagnosis of lung cancer (AUC=0.822 , sensitivity=63.6% , specificity=90.2% , P<0.01 ). Conclusion: This study demonstrates that the CRDS breath isoprene analysis system can effectively analyze a large sample of human breath isoprene, and preliminarily confirms the use of breath isoprene as a biomarker for lung diseases.

1 September 2020 in Analytica Chimica Acta
Verified
Journal Article
Closed access
QLQingyuan Li
Qingyuan Li
JLJing Li
Jing Li
XWXin Wei
Xin Wei
YLYingxin Li
Yingxin Li
MSMeixiu Sun
Meixiu Sun

30 September 2021 in Membranes
Verified
Journal Article
Open access
PDF file
WFWeigui Fu
Weigui Fu
GLGuoxia Li
Guoxia Li
GZGaowei Zhai
Gaowei Zhai
Yunji XieYunji Xie
Yunji Xie
MSMeixiu Sun
Meixiu Sun
LCLi Chen
Li Chen
In this work, a facile preparation method was proposed to reduce natural organics fouling of hydrophobic membrane via UV grafting polymerization with methacrylic acid (MAAc) and methyl acrylamide (MAAm) as hydrophilic monomers, followed by multihydrogen bond self-assembly. The resulting poly(vinylidene fluoride)-membranes were characterized with respect to monomer ratio, chemical structure and morphology, surface potential, and water contact angle, as well as water flux and organic foulants ultrafiltration property. The results indicated that the optimal membrane modified with a poly(MAAc-co-MAAm) polymer gel layer derived from a 1:1 monomer ratio exhibited superior hydrophilicity and excellent gel layer stability, even after ultrasonic treatment or soaking in acid or alkaline aqueous solution. The initial water contact angle of modified membranes was only 36.6° ± 2.9, and dropped to 0° within 13 s. Moreover, flux recovery rates (FRR) of modified membranes tested by bovine serum albumin (BSA), humic acid (HA), and sodium alginate (SA) solution, respectively, were all above 90% after one-cycle filtration (2 h), significantly higher than that of the pure membrane (70–76%). The total fouling rates (Rt) of the pure membrane for three foulants were as high as 47.8–56.2%, while the Rt values for modified membranes were less than 30.8%. Where Rt of BSA dynamic filtration was merely 10.7%. The membrane designed through grafting a thin-layer hydrophilic hydrogel possessed a robust antifouling property and stability, which offers new insights for applications in pure water treatment or protein purification.

5 February 2022 in Infrared Physics & Technology
Verified
Journal Article
Closed access
HLHongxiao Li
Hongxiao Li
ZXzhiguang xiang
zhiguang xiang
Chuan QinChuan Qin
Chuan Qin
YLYingxin Li
Yingxin Li
MSMeixiu Sun
Meixiu Sun

28 July 2026 in Chest
Verified
Journal Article
Open access
JQJianwen Qin
Jianwen Qin
MSMeixiu Sun
Meixiu Sun
XLXin Li
Xin Li
XDXiaoyan Duan
Xiaoyan Duan
YLYuechuan Li
Yuechuan Li
DSDaqiang Sun
Daqiang Sun