Chao Li

Dr. Chao Li


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PLPeixi Li
Peixi Li
Yannick BenezethYannick Benezeth
Yannick Benezeth
RMRichard Macwan
Richard Macwan
KNKeisuke Nakamura
Keisuke Nakamura
RGRandy Gomez
Randy Gomez
Fan YangFan Yang
Fan Yang
Many previous studies have shown that the remote photoplethysmography (rPPG) can measure the Heart Rate (HR) signal with very high accuracy. The remote measurement of the Pulse Rate Variability (PRV) signal is also possible, but this is much more complicated because it is then necessary to detect the peaks on the temporal rPPG signal, which is usually quite noisy and has a lower temporal resolution than PPG signals obtained by contact equipment. Since the PRV signal is vital for various applications such as remote recognition of stress and emotion, the improvement of PRV measurement by rPPG is a critical task. Contact based PRV measurement has already been investigated, but the research on remotely measured PRV is very limited. In this paper, we propose to use the Periodic Variance Maximization (PVM) method to extract the rPPG signal and event-related Two-Window algorithm to improve the peak detection for PRV measurement. We have made several contributions. Firstly, we show that the newly proposed PVM method and Two-Window algorithm can be used for PRV measurement in the non-contact scenario. Secondly, we propose a method to adaptively determine the parameters of the Two-Window method. Thirdly, we compare the algorithm with other attempts for improving the non-contact PRV measurement such as the Slope Sum Function (SSF) method and the Local Maximum method. We calculated several features and compared the accuracy based on the ground truth provided by contact equipment. Our experiments showed that this algorithm performed the best of all the algorithms.

6 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FYFan Yin
Fan Yin
CLChao Li
Chao Li
HWHaibin WANG
Haibin WANG
Fan YangFan Yang
Fan Yang
Passive acoustic target detection has been a hot research topic for a few decades. Azimuth recording diagram is one of the most promising techniques to estimate the arrival direction of the interested signal by visualizing the sound wave information. However, this method is challenged by the random ambient noise, resulting in low reliability and short effective distance. This paper presents a real-time postprocessing framework for passive acoustic target detection modalities by using a sonar array, in which image processing methods are used to automate the target detecting and tracking on the azimuth recording diagram. The simulation results demonstrate that the proposed approach can provide a higher reliability compared with the conventional ones, and is suitable for the constraints of real-time tracking.