This paper presents the development of a new medical robot system comprising a spherical remote center motion (RCM) mechanism with modular design and two mechanical decoupling methods for Minimally Invasive Surgery (MIS). We achieved excellent comprehensive performance indices through a novel multi-objective optimization model comprising four optimization objective functions, three constrained conditions and two optimization variables. In order to enhance the manipulability, remove the coupling between motors, and reduce the control difficulty, two new decoupling mechanism means were proposed to remove coupling motion between the wrist and pincers, coupling motion between the translational joint of mobile platform and four interface disks of surgical instrument as a results of rear drive motor, respectively. The control system architecture is designed to include intuitive motion control, incremental motion control, and proportional motion control. Master-slave attitude registration and surgical instrument replacement strategies improve the master-slave control efficiency. We tested the spherical RCM mechanism performance indices and developed two mechanical decoupling methods and a master–slave control algorithm. Our experimental test results validated that fixing point accuracy, the coupling motions, the positioning and repeated positioning accuracy of the MIS robot, and master–slave control algorithm meet the requirements of MIS. Successful animal experiments confirmed effectiveness of the novel MIS robot system.
In this paper, we designed a 8 degrees of freedom (DOFs) haptic device for applications in minimally invasive surgical robot. The device can provide three translational, three rotational and a grasping motion and force feedback capability. It is composed of three parts, including an arm mechanism, a redundant wrist mechanism and a grasper mechanism. The kinematics and gravity compensation algorithms are also detailed in the paper. In addition, the haptic device and a slave surgical robot for minimally invasive surgery (MIS) developed by our lab are integrated as a master-slave surgical robotic system in this paper. In the master-slave robotic system, a new control system is designed to realize real-time mater-slave control based on EtherCAT bus technology. Experiments show that the haptic device can effectively compensate gravity at any position in its workspace and successfully realize master-slave operation by the control method, which prove the haptic device designed in this paper can be used as a master manipulator to control the surgical robot.
8 March 2021 in IEEE Transactions on Instrumentation and Measurement
Grip force measurement enables better control performance for robot-assisted minimally invasive surgery (RMIS). A deep-learning-based method is proposed to measure the instrument grip force without mounting additional sensors in this article. First, the training trajectory and input data frame are studied. Seven data are derived from the original sensor data, and a binary butterfly optimization algorithm with opposite-based learning (bBOA-OBL) is conducted to form the suitable input data frame. Based on the data frame, a novel convolutional network with an attention mechanism and feedforward of current (CAM-FoC) is proposed to calculate the grip force. The results of the ablation study tell that the master-slave trajectory has the highest accuracy, the optimized input data frame can reduce the error by 17%, and each component of CAM-FoC can enhance the measurement accuracy. Experiments and comparisons are also carried out. The root mean squared error (RMSE) in the experiment is only 0.1233 N and is lower than four other popular methods. In addition, the average computation time is around 2 ms on different platforms. The method manifests higher measurement accuracy than the state-of-the-art and is of acceptable computational complexity. The technology would potentially achieve grip force feedback in clinical usage, which can significantly improve surgery performance. The method could also be used by other robots composed of the cable-pulley mechanism to acquire external forces.
22 April 2021 in The International Journal of Medical Robotics and Computer Assisted Surgery
Applying a robot system in ultrasound-guided percutaneous intervention is an effective approach for prostate cancer diagnosis and treatment. The limited space for robot manipulation restricts structure volume and motion. In this paper, an 8-degree-of-freedom robot system is proposed for ultrasound probe manipulation, needle positioning, and needle insertion. A novel parallel structure is employed in the robot system for space saving, structural rigidity, and collision avoidance. The particle swarm optimization method based on informative value is proposed for kinematic parameter identification to calibrate the parallel structure accurately. The method identifies parameters in the modified kinematic model stepwise according to parameter discernibility. Verification experiments prove that the robot system can realize motions needed in targeting. By applying the calibration method, a reasonable, reliable forward kinematic model is built, and the average errors can be limited to 0.963 and 1.846 mm for insertion point and target point, respectively.
17 January 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery