Pancheng Zhu

Mr. Pancheng Zhu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HPHanmin Peng
Hanmin Peng
Jianzhi YangJianzhi Yang
Jianzhi Yang
Xiaolong LuXiaolong Lu
Xiaolong Lu
PZPancheng Zhu
Pancheng Zhu
DWDawei Wu
Dawei Wu
To realize an efficient translation in a narrow space, a surface milli-walker based on linear piezoelectric actuation is proposed, fabricated, and tested. Operating at the second order out-of-plane flexural vibration mode, the proposed surface walker is able to realize a linear movement on demand. The surface walker has a weight of only 0.135 g with package size of 6 mm × 2 mm × 2 mm. Experimental results show that the maximum velocity and drag force of the walker can reach up to 200 mm/s and 10 mN, respectively. The velocity of the walker can be smoothly adjusted over a range of 0.15 mm/s to 200 mm/s. In addition, its startup time is as quick as 6 ms. The milli-walker holds great promises for numerous potential applications in precise instruments.

3 March 2024 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
PZPancheng Zhu
Pancheng Zhu
ISIgnasi Simon
Ignasi Simon
IKIda Kokalari
Ida Kokalari
DKDaniel S. Kohane
Daniel S. Kohane
ARAlina Y. Rwei
Alina Y. Rwei

10 February 2023 in Science Advances
Verified
Journal Article
Closed access
PZPancheng Zhu
Pancheng Zhu
VPVasileios A. Papadimitriou
Vasileios A. Papadimitriou
JDJeanne E. van Dongen
Jeanne E. van Dongen
JCJulia Cordeiro
Julia Cordeiro
YNYannick Neeleman
Yannick Neeleman
ARAlina Y. Rwei
Alina Y. Rwei
Endotoxin is a deadly pyrogen, rendering it crucial to monitor with high accuracy and efficiency. However, current endotoxin detection relies on multistep processes that are labor-intensive, time-consuming, and unsustainable. Here, we report an aptamer-based biosensor for the real-time optical detection of endotoxin. The endotoxin sensor exploits the distance-dependent scattering of gold nanoparticles (AuNPs) coupled to a gold nanofilm. This is enabled by the conformational changes of an endotoxin-specific aptamer upon target binding. The sensor can be used in an ensemble mode and single-particle mode under dark-field illumination. In the ensemble mode, the sensor is coupled with a microspectrometer and exhibits high specificity, reliability (i.e., linear concentration to signal profile in logarithmic scale), and reusability for repeated endotoxin measurements. Individual endotoxins can be detected by monitoring the color of single AuNPs via a color camera, achieving single-molecule resolution. This platform can potentially advance endotoxin detection to safeguard medical, food, and pharmaceutical products.

27 February 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
PZPancheng Zhu
Pancheng Zhu
HPHanmin Peng
Hanmin Peng
Xiaolong LuXiaolong Lu
Xiaolong Lu
MGMingsen Guo
Mingsen Guo
GZGai Zhao
Gai Zhao
WLWenwen Liu
Wenwen Liu
Micro robots, due to their light weight, small size and high mobility, can explore narrow space or hazardous locations that humans or larger robots cannot reach. Consequently, both academia and industry are concerned with the development of advanced microrobots. In this paper, we design a steerable miniature legged robot (SMLR) which possesses light weight and controllable linear/steerable motion by using two piezoelectric bending actuators. Its dimensions are 35 mm × 30 mm × 9 mm (length × width × height) and mass is 9 g. User can modulate the speed, turning radius, and load capacity of the robot by simply tuning the driving voltage. The robot exhibits a speed of 330 mm s −1 and a turning radius of 102 mm upon a driving voltage of 200 V and a frequency of 8.67 kHz. Moreover, it is capable of driving a 55 g embedded mass at a speed of 20 mm s −1 under a voltage of 200 V, and its simple design is ideal for down-sizing. Further, we establish a series of open-loop control programs in a virtual instrument through LabVIEW to accurately control the behavior of the SMLR (the location error is less than 5 mm), demonstrating its great potential in practical applications such as movement in a narrow space.

24 September 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PZPancheng Zhu
Pancheng Zhu
HPHanmin Peng
Hanmin Peng
LMLinli Mao
Linli Mao
JTJun Tian
Jun Tian
Modern advanced minimally invasive surgery has been implemented for most of the significant gastrointestinal diseases. However, patients with coagulopathy or unresectable tumors cannot be cured by current treatment methods. Moreover, other existing medical devices for targeted drug release are too large to be applied in gastric endoscope because the diameter of the biopsy channel is smaller than 3 mm. To address it, in this work, we developed a piezoelectric single crystal ultrasonic transducer (the diameter was only 2.2 mm and the mass was 0.076 g) to produce acoustic waves, which could promote the drug release in the designed position of the digestive tract through an endoscope. It exhibited the electromechanical coupling coefficient of 0.36 and the center frequency of 6.9 MHz with the -6 dB bandwidth of 23%. In in vitro sonophoresis experiment, the gastric mucosa permeability to Bovine Serum Albumin increased about 5.6 times when the ultrasonic transducer was activated at 40 Vpp and 60 % duty ratio, proving that employment of this transducer could facilitate drug penetration in the gastric mucosa. Meanwhile, the permeability could be adjusted by tuning the duty ratio of the ultrasonic transducer. The corresponding sonophoresis mechanism was related to the acoustic streaming and the thermal effect produced by the transducer. In addition, the measured maximum power density was 128 mW/cm2 and the mechanical index of the ultrasonic transducer was 0.02. The results held a great implication for applications of the transducer for targeted drug release in the gastrointestinal tract.

21 February 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
PZPancheng Zhu
Pancheng Zhu
HPHanmin Peng
Hanmin Peng
JYJianzhi Yang
Jianzhi Yang
TMTing Mao
Ting Mao
JSJuan Sheng
Juan Sheng
Low frequency sonophoresis (LFS) is currently being attempted as a transdermal drug delivery method in clinical areas. However, it lacks both an effective control method and the equipment to satisfy the varying drug dosage requirements of individual patients. Herein, a novel method aimed at controlling permeability is proposed and developed, using a pressure control strategy which is based on an accurate, adjustable and non-invasive ultrasound transdermal drug delivery system in in vitro LFS. The system mainly consists of a lead screw linear ultrasonic motor and an ultrasonic transducer, in which the former offers pressure and the latter provides ultrasound wave in the liquid. The ultrasound can enhance non-invasive permeation and the pressure from the motor can control the permeability. The calculated and experimental results demonstrate that the maximum pressure on artificial skin is under the area with the maximum vibration amplitude of the ultrasonic transducer, and the total pressure consists of acoustic pressure from the transducer and approximate static pressure from the motor. Changing the static pressure from the ultrasonic motor can effectively control the non-invasive permeability, by adjusting the duty ratio or the amplitude of the motor’s driving voltage. In addition, the permeability control of calcein by thrust control is realized in 15 min, indicating the suitability of this method for application in accurate medical technology. The obtained results reveal that the issue of difficult permeability control can be addressed, using this control method in in vitro LFS to open up a route to the design of accurate drug delivery technology for individual patients.