Gianluca De Masi

Dr. Gianluca De Masi

Consorzio RFX, corso Stati Uniti 4, 35127 Padova, Italy
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2019 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
LMLionello Marrelli
Lionello Marrelli
RCRoberto Cavazzana
Roberto Cavazzana
DBDaniele Bonfiglio
Daniele Bonfiglio
MGMarco Gobbin
Marco Gobbin
GMGiuseppe Marchiori
Giuseppe Marchiori
TTthe RFX-Mod Team
the RFX-Mod Team

12 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Bruno GoncalvesBruno Goncalves
Bruno Goncalves
PVPaulo Varela
Paulo Varela
ASAntonio Guilherme Slva
Antonio Guilherme Slva
FSFilipe da Silva
Filipe da Silva
JSJorge Manuel Santos
Jorge Manuel Santos
ODOcleto D’arcangelo
Ocleto D’arcangelo
Providing energy from fusion and finding ways to scale up the fusion process to commercial proportions in an efficient, economical, and environmentally benign way is one of the grand challenges for engineering. Controlling the burning plasma in real-time is one of the critical issues that need to be addressed. Plasma Position Reflectometry (PPR) is expected to have an important role in next-generation fusion machines, such as DEMO, as a diagnostic to monitor the position and shape of the plasma continuously, complementing magnetic diagnostics. The reflectometry diagnostic uses radar science methods in the microwave and millimetre wave frequency ranges and is envisaged to measure the radial edge density profile at several poloidal angles providing data for the feedback control of the plasma position and shape. While significant steps have already been given to accomplish that goal, with proof of concept tested first in ASDEX-Upgrade and afterward in COMPASS, important, ground-breaking work is still ongoing. The Divertor Test Tokamak (DTT) facility presents itself as the appropriate future fusion device to implement, develop, and test a PPR system, thus contributing to building a knowledge database in plasma position reflectometry required for its application in DEMO. At DEMO, the PPR diagnostic’s in-vessel antennas and waveguides, as well as the magnetic diagnostics, may be exposed to neutron irradiation fluences 5 to 50 times greater than those experienced by ITER. In the event of failure of either the magnetic or microwave diagnostics, the equilibrium control of the DEMO plasma may be jeopardized. It is, therefore, imperative to ensure that these systems are designed in such a way that they can be replaced if necessary. To perform reflectometry measurements at the 16 envisaged poloidal locations in DEMO, plasma-facing antennas and waveguides are needed to route the microwaves between the plasma through the DEMO upper ports (UPs) to the diagnostic hall. The main integration approach for this diagnostic is to incorporate these groups of antennas and waveguides into a diagnostics slim cassette (DSC), which is a dedicated complete poloidal segment specifically designed to be integrated with the water-cooled lithium lead (WCLL) breeding blanket system. This contribution presents the multiple engineering and physics challenges addressed while designing reflectometry diagnostics using radio science techniques. Namely, short-range dedicated radars for plasma position and shape control in future fusion experiments, the advances enabled by the designs for ITER and DEMO, and the future perspectives. One key development is in electronics, aiming at an advanced compact coherent fast frequency sweeping RF back-end [23–100 GHz in few μs] that is being developed at IPFN-IST using commercial Monolithic Microwave Integrated Circuits (MMIC). The compactness of this back-end design is crucial for the successful integration of many measurement channels in the reduced space available in future fusion machines. Prototype tests of these devices are foreseen to be performed in current nuclear fusion machines.

23 September 2020 in Nuclear Fusion
Verified
Journal Article
Closed access
GGG. Grenfell
G. Grenfell
Monica SpolaoreMonica Spolaore
Monica Spolaore
DAdomenico abate
domenico abate
LCL. Carraro
L. Carraro
LML. Marrelli
L. Marrelli
TTthe RFX-mod team
the RFX-mod team

24 January 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
SMS. Munaretto
S. Munaretto
SBS. Dal Bello
S. Dal Bello
PIP. Innocente
P. Innocente
MAMatteo Agostini
Matteo Agostini
FAF. Auriemma
F. Auriemma
DTD. Terranova
D. Terranova
Plasma–wall interaction is one of the most important issues that present magnetic confinement devices have to face. In the RFX-mod reversed field pinch experiment plasma–wall interaction has become a hard point increasing plasma current up to the RFX-mod maximum design value of 2 MA, since in this case local power deposition can be as high as 10 MW m−2. Since the first wall of RFX-mod is entirely covered by graphite tiles different techniques have been tested to control hydrogen wall influx: He glow discharges cleaning, He discharges at high plasma currents, wall boronization and baking. With the best results obtained by boronization, at high plasma currents all such techniques improve the situation but do not allow a complete and stationary hydrogen influx reduction. Furthermore, in the presence of localized high power load the wall still responds providing very high influxes. In order to improve this situation wall conditioning by lithium has been tested. As a first lithization method to deposit a controllable amount of lithium on the wall, a room temperature pellet injector has been used (maximum pellet diameter of 1.8 mm and maximum length of 5 mm). Lithium coatings with a theoretical thickness of about 10 nm have been applied both to clean graphite tiles and over boronized ones. Lithization demonstrated to be effective in lowering hydrogen wall recycling to a value smaller than that of boronized graphite, with the effect lasting 20–30% more than in the boronized case. Compared with boronization, lithization slightly improves (by about 30%) particle confinement time and also clearly affects edge particle transport providing a lower edge density and more peaked density profiles. Lithization also reduces carbon content by about 10% over boronization but still no clear improvement has been observed in terms of energy confinement. Similar results have been obtained performing lithization over boronized graphite.

4 June 2024 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
LCL. Carraro
L. Carraro
Matteo ZuinMatteo Zuin
Matteo Zuin
DAdomenico abate
domenico abate
PAP. Agostinetti
P. Agostinetti
MAMatteo Agostini
Matteo Agostini
BZB. Zaniol
B. Zaniol
The RFX-mod2 device, the upgraded version of the previous RFX-mod with a modified magnetic boundary, is presently under realization and will start to be operated in 2025. Significant upgrades of the diagnostic capabilities have been proposed and are under development. These include a largely increased number of in-vessel magnetic and electrostatic sensors, a new fast reciprocating manipulator for the exploration of the edge plasma in a wide range of experimental conditions, the improved Thomson scattering and soft x-ray diagnostics system for a detailed determination of the behavior of the electron temperature profile, new dedicated systems for the space and time resolved analysis of x-ray spectra and neutron rate, a reflectometric diagnostic for real-time determination of plasma position, two diagnostics devoted to the imaging of light impurities and influxes behavior along with arrays of halo current sensors. These diagnostic upgrades will be accompanied by a significant effort to improve the control of the electron density and of the impurity influxes by means of proper treatment of plasma facing components with in-vessel fixed electrodes distributed over the first wall. The described advancements will allow a deeper understanding of physics phenomena in the wide variety of magnetic configurations, including the tokamak, the reversed-field pinch and the Ultra-low q, which can be produced in RFX-mod2 thanks to its flexibility and unique MHD control capabilities.

17 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Luigi CordaroLuigi Cordaro
Luigi Cordaro
Gianluca De MasiGianluca De Masi
Gianluca De Masi
AFAlessandro Fassina
Alessandro Fassina
CGClarice Gareri
Clarice Gareri
APAntonio Pimazzoni
Antonio Pimazzoni
Emilio MartinesEmilio Martines
Emilio Martines
Plasma Medicine tools exploit the therapeutic effects of the exposure of living matter to plasma produced at atmospheric pressure. Since these plasmas are usually characterized by a non-thermal equilibrium (highly energetic electrons, low temperature ions), thermal effects on the substrate are usually considered negligible. Conversely, reactive oxygen and nitrogen species (RONS), UV radiation and metastables are thought to play a major role. In this contribution, we compare the presence of thermal effects in different operational regimes (corresponding to different power levels) of the Plasma Coagulation Controller (PCC), a plasma source specifically designed for accelerating blood coagulation. In particular, we analyze the application of PCC on human blood samples (in vitro) and male Wistar rats tissues (in vivo). Histological analysis points out, for the highest applied power regime, the onset of detrimental thermal effects such as red cell lysis in blood samples and tissues damages in in-vivo experiments. Calorimetric bench tests performed on metallic targets show that the current coupled by the plasma on the substrate induces most of measured thermal loads through a resistive coupling. Furthermore, the distance between the PCC nozzle and the target is found to strongly affect the total power.