In the present study, we examined the influence of shoe lacing on foot biomechanics in running. Twenty experienced rearfoot runners ran in six different lacing conditions across a force platform at a speed of 3.3 m · s−1. Foot pronation during contact, tibial acceleration, and plantar pressure distribution of the right leg were recorded. The test conditions differed in the number of laced eyelets (1, 2, 3, 6 or 7) and in lacing tightness (weak, regular or strong). The results show reduced loading rates (P < 0.05) and pronation velocities (P < 0.01) in the tightest and highest lacing conditions. The lowest peak pressures under the heel and lateral midfoot (P < 0.01) were observed in the high (seven-eyelet) lacing pattern. Regular six-eyelet cross-lacing resulted in higher loading rates (P < 0.05) and higher peak heel pressures (P < 0.01) than seven-eyelet lacing, without any significant differences in perceived comfort. The low lace shoe conditions resulted in lower impacts (P < 0.01) and lower peak pressures under metatarsal heads III and V (P < 0.01), which is probably induced by the foot sliding within the shoe. A firm foot-to-shoe coupling with higher lacing leads to a more effective use of running shoe features and is likely to reduce the risk of lower limb injury.
The purpose of this study was to investigate the effects of four lacing patterns (one regular, one tight, and two seven-eyelet lacings) on dorsal foot pressures during running and the perception of comfort and stability with 14 male rearfoot runners. By using a pressure insole, peak dorsal pressures were measured under the shoe's tongue. Highest peak pressures were found above the talus, the navicular bone, and the first ray. Seven-eyelet lacings showed a significant enhancement of perceived stability without differences in perceived comfort compared with a regular six-eyelet technique. Reduction of pressure on the talus, the navicular bone, and the extensor tendons is related to better comfort. With individually chosen special seven-eyelet lacings runners can improve foot-shoe coupling without increasing peak dorsal pressures on the tarsus. Knowledge of the location of the dorsal pressure distribution is useful for new tongue and lacing constructions to improve comfort in running shoes while maintaining stability.
The aim of the present study was to investigate the concurrent validity and the test–retest reliability of an electronic contact mat for drop jump assessment in physically active adults. Seventy-nine young, physically active adults participated in the validity study, and 49 subjects were recruited for the reliability study. The motor task required subjects to perform two-legged drop jumps using drop heights of 24, 43, and 62 cm as well as one-legged drop jumps with the left and right leg using a drop height of 24 cm. Ground contact times were simultaneously quantified with an electronic contact mat, a force plate (i.e., gold standard), and a light-barrier system (another criterion device). Concurrent validity was assessed using intraclass correlation coefficient (ICC), systematic bias, limits of agreement, and linear regression analysis. Test–retest reliability (one week apart) was determined by calculating the ICC, the standard error of measurement (SEM), the coefficient of variation (CV), and Lin´s concordance correlation coefficient (рc). Further, we determined the minimal detectable change (MDC95%). Irrespective of drop height and jump condition, good agreements between testing devices (ICC ≥ 0.95) were shown. Compared to the force plate (−0.6 to 3.1 ms) but not to the light-barrier system (31.4 to 41.7 ms), the contact mat showed low systematic bias values. In terms of test–retest reliability, our analyses showed that the measuring devices are in agreement (ICC: 0.70–0.92; SEM: 8.5–18.4 ms; CV: 3.6–6.4%). Depending on the measurement device, drop height, and jump condition, a MDC95% value ranging from 23.6 to 50.9 ms represents the minimum amount of change needed to identify practical relevant effects in repeated measurements of drop jump performance. Our findings indicate that the electronic contact mat is a valid and reliable testing device for drop jump assessment from different drop heights in young physically active adults.
Compared to force-plates, pressure-detecting insoles have the advantage that vertical ground reaction force (vGRF) can be estimated under field rather than laboratory conditions. However, the question arises whether insoles also provide valid and reliable results compared to a force-plate (i.e., the gold standard). The study aimed to investigate the concurrent validity and test–retest reliability of pressure-detecting insoles during static and dynamic movements. Twenty-two healthy young adults (12 females) performed standing, walking, running, and jumping movements while simultaneously collecting pressure (GP MobilData WiFi, GeBioM mbH, Münster, Germany) and force (Kistler®) data twice, 10 days apart. Concerning validity, ICC values showed excellent agreement (ICC > 0.75), irrespective of the test condition. Further, the insoles underestimated (mean bias: −4.41 to −37.15%) most of the vGRF variables. Concerning reliability, ICC values for nearly all test conditions also showed excellent agreement, and the SEM was rather low. Lastly, most of the MDC95% values were low (≤5%). The predominantly excellent ICC values for between-devices (i.e., concurrent validity) and between-visits (i.e., test–retest reliability) comparisons suggest that the tested pressure-detecting insoles can be used under field-based conditions for a valid and reliable estimation of relevant vGRF variables during standing, walking, running, and jumping.