This paper deals with new approaches to analyse electrocardiogram (ECG) signals for extracting useful diagnostic features. Initially, elimination of different types of noise is carried out using maximal overlap discrete wavelet transform (MODWT) and universal thresholding. Next, R-peak fiducial points are detected from these noise free ECG signals using discrete wavelet transform along with thresholding. Then, extraction of other features, viz., Q waves, S waves, P waves, T waves, P wave onset and offset points, T wave onset and offset points, QRS onset and offset points are identified using some rule based algorithms. Eventually, other important features are computed using the above extracted features. The software developed for this purpose has been validated by extensive testing of ECG signals acquired from the MIT-BIH database. The resulting signals and tabular results illustrate the performance of the proposed method. The sensitivity, predictivity and error of beat detection are 99.98%, 99.97% and 0.05%, respectively. The performance of the proposed beat detection method is compared to other existing techniques, which shows that the proposed method is superior to other methods.
In this paper, a new approach to remove noise present in ECG signal is proposed. Baseline wander and high frequency noise is eliminated by using computationally efficient linear phase filter ie. interpolated finite impulse response (IFIR) filter. The IFIR filter is designed by using Kaiser window function to achieve high stop band attenuation. As compared to other methods, the technique presented could achieve a reduction in computational complexity by 80.14 percent. Data compression is also performed in this study using wavelet packet decomposition along with Run-length encoding. Run-length encoding is used to improve the compression performance. For evaluation of the performance of IFIR filter, computational cost reduction (CRC) parameter is used, which directly depended on multipliers and adders. Different fidelity factors are considered to evaluate the performance of the proposed data compression method, viz., compression ratio (CR), signal to noise ratio (SNR), retained energy (RE) and percent root mean square difference (PRD), their magnitude being 25.13, 38.93, 99.10 and 1.75, respectively. MIT-BIH arrhythmia database has been utilized to judge the entire set of computations mentioned above noise removal and ECG signal compression. This work also includes beat detection of original and reconstructed signals. Simulated results show that decompressed signal is a replica of the input signal.
This work presents a new Electrocardiogram (ECG) data compression technique based on the optimum two channel quadrature mirror filter (QMF) bank. Firstly, prototype filter is designed using ParksMcClellan algorithm. To avoid amplitude distortion linear optimization technique is used by varying passband edge frequency of prototype filter. Than after, QMF bank is designed by optimized prototype filter. Data compression is done by decomposing the signal using optimum QMF bank and truncates the irrelevant coefficients using level thresholding. Further, Run-Length Encoding (RLE) is applied to improve the compression performance. The proposed method is tested using MIT-BIH database. The performance is estimated by different parameters viz., the compression ratio (CR), percentage root-mean-square difference (PRD), signal to noise ratio (SNR), and quality score (QS). Experimental results show that proposed method provides QS up to 20.10 and table of comparison shows that this work is better than several other existing methods in terms of CR and PRD. Diagnostic information of both original and reconstructed signals is compared, which shows both signals have same diagnostic information.
27 January 2026 in Biomedical Signal Processing and Control