Zhen Gang Xiao

Dr. Zhen Gang Xiao

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2010 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ZKZeeshan O Khokhar
Zeeshan O Khokhar
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Background: Surface electromyography (sEMG) signals have been used in numerous studies for the classification of hand gestures and movements and successfully implemented in the position control of different prosthetic hands for amputees. sEMG could also potentially be used for controlling wearable devices which could assist persons with reduced muscle mass, such as those suffering from sarcopenia. While using sEMG for position control, estimation of the intended torque of the user could also provide sufficient information for an effective force control of the hand prosthesis or assistive device. This paper presents the use of pattern recognition to estimate the torque applied by a human wrist and its real-time implementation to control a novel two degree of freedom wrist exoskeleton prototype (WEP), which was specifically developed for this work. Methods: Both sEMG data from four muscles of the forearm and wrist torque were collected from eight volunteers by using a custom-made testing rig. The features that were extracted from the sEMG signals included root mean square (rms) EMG amplitude, autoregressive (AR) model coefficients and waveform length. Support Vector Machines (SVM) was employed to extract classes of different force intensity from the sEMG signals. After assessing the off-line performance of the used classification technique, the WEP was used to validate in real-time the proposed classification scheme. Results: The data gathered from the volunteers were divided into two sets, one with nineteen classes and the second with thirteen classes. Each set of data was further divided into training and testing data. It was observed that the average testing accuracy in the case of nineteen classes was about 88% whereas the average accuracy in the case of thirteen classes reached about 96%. Classification and control algorithm implemented in the WEP was executed in less than 125 ms. Conclusions: The results of this study showed that classification of EMG signals by separating different levels of torque is possible for wrist motion and the use of only four EMG channels is suitable. The study also showed that SVM classification technique is suitable for real-time classification of sEMG signals and can be effectively implemented for controlling an exoskeleton device for assisting the wrist.

20 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Information about limb movements can be used for monitoring physical activities or for human-machine-interface applications. In recent years, a technique called Force Myography (FMG) has gained ever-increasing traction among researchers to extract such information. FMG uses force sensors to register the variation of muscle stiffness patterns around a limb during different movements. Using machine learning algorithms, researchers are able to predict many different limb activities. This review paper presents state-of-art research and development on FMG technology in the past 20 years. It summarizes the research progress in both the hardware design and the signal processing techniques. It also discusses the challenges that need to be solved before FMG can be used in an everyday scenario. This paper aims to provide new insight into FMG technology and contribute to its advancement.

1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Body motion data registered by wearable sensors can provide objective feedback to patients on the effectiveness of the rehabilitation interventions they undergo. Such a feedback may motivate patients to keep increasing the amount of exercise they perform, thus facilitating their recovery during physical rehabilitation therapy. In this work, we propose a novel wearable and affordable system which can predict different postures of the upper-extremities by classifying force myographic (FMG) signals of the forearm in real-time.

7 April 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
RLRitik Looned
Ritik Looned
JWJacob Webb
Jacob Webb
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Background: The aim of the present study is to demonstrate, through tests with healthy volunteers, the feasibility of potentially assisting individuals with neurological disorders via a portable assistive technology for the upper extremities (UE). For this purpose the task of independently drinking a glass of water was selected, as it is one of the most basic and vital activities of the daily living that is unfortunately not achievable by individuals severely affected by stroke. Methods: To accomplish the aim of this study we introduce a wearable and portable system consisting of a novel lightweight Robotic Arm Orthosis (RAO), a Functional Electrical Stimulation (FES) system, and a simple wireless Brain-Computer Interface (BCI). This system is able to process electroencephalographic (EEG) signals and translate them into motions of the impaired arm. Five healthy volunteers participated in this study and were asked to simulate stroke patient symptoms with no voluntary control of their hand and arm. The setup was designed such as the volitional movements of the healthy volunteers’ UE did not interfere with the evaluation of the proposed assistive system. The drinking task was split into eleven phases of which seven were executed by detecting EEG-based signals through the BCI. The user was asked to imagine UE motion related to the specific phase of the task to be assisted. Once detected by the BCI the phase was initiated. Each phase was then terminated when the BCI detected the volunteers clenching their teeth. Results: The drinking task was completed by all five participants with an average time of 127 seconds with a standard deviation of 23 seconds. The incremental motions of elbow extension and elbow flexion were the primary limiting factors for completing this task faster. The BCI control along with the volitional motions also depended upon the users pace, hence the noticeable deviation from the average time. Conclusion: Through tests conducted with healthy volunteers, this study showed that our proposed system has the potential for successfully assisting individuals with neurological disorders and hemiparetic stroke to independently drink from a glass.

16 May 2017 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet

28 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Force myography (FMG) is an emerging method to register muscle activity of a limb using force sensors for human–machine interface and movement monitoring applications. Despite its newly gained popularity among researchers, many of its fundamental characteristics remain to be investigated. The aim of this study is to identify the minimum sampling frequency needed for recording upper-limb FMG signals without sacrificing signal integrity. Twelve healthy volunteers participated in an experiment in which they were instructed to perform rapid hand actions with FMG signals being recorded from the wrist and the bulk region of the forearm. The FMG signals were sampled at 1 kHz with a 16-bit resolution data acquisition device. We downsampled the signals with frequencies ranging from 1 Hz to 500 Hz to examine the discrepancies between the original signals and the downsampled ones. Based on the results, we suggest that FMG signals from the forearm and wrist should be collected with minimum sampling frequencies of 54 Hz and 58 Hz for deciphering isometric actions, and 70 Hz and 84 Hz for deciphering dynamic actions. This fundamental work provides insight into minimum requirements for sampling FMG signals such that the data content of such signals is not compromised.