Clive Beggs

Prof. Clive Beggs

School of Sport, Leeds Beckett University, Leeds, UK
orcid
Emeritus Professor of Applied Physiology, School of Sport, L...

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2006 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LGL.F. Gaunt
L.F. Gaunt
Clive BeggsClive Beggs
Clive Beggs
George E. GeorghiouGeorge E. Georghiou
George E. Georghiou
Biological decontamination using a nonthermal gas discharge at atmospheric pressure in air is the subject of significant research effort at this time. The mechanism for bacterial deactivation undergoes a lot of speculation, particularly with regard to the role of ions and reactive gas species. Two mechanisms have been proposed: electrostatic disruption of cell membranes and lethal oxidation of membrane or cytoplasmic components. Results show that death is accompanied by cell lysis and fragmentation in Gram-negative bacteria but not Gram-positive species, although cytoplasmic leakage is generally observed. Gas discharges can be a source of charged particles, ions, reactive gas species, radicals, and radiation (ultraviolet, infrared, and visible), many of which have documented biocidal properties. The individual roles played by these in decontamination are not well understood or quantified. However, the reactions of some species with biomolecules are documented otherwise in the literature. Oxidative stress is relatively well studied, and it is likely that exposure to gas discharges in air causes extreme oxidative challenge. In this paper, a review is presented of the major reactive species generated by nonthermal plasma at atmospheric pressure and the known reactions of these with biological molecules. Understanding these mechanisms becomes increasingly important as plasma-based decontamination and sterilization devices come closer to a wide-scale application in medical, healthcare, food processing, and air purification applications. Approaches are proposed to elucidate the relative importance of reactive species

1 February 2003 in Indoor and Built Environment
Verified
Journal Article
Closed access
Clive BeggsClive Beggs
Clive Beggs
Airborne transmission is known to be the route of infection for diseases such as tuberculosis and aspergillosis. It has also been implicated in nosocomial outbreaks of MRSA, Acinetobacter spp. and Pseudomonas spp. Despite this there is much scepticism about the role that airborne transmission plays in nosocomial outbreaks. This paper investigates the airborne spread of infection in hospital buildings, and evaluates the extent to which it is a problem. It is concluded that although contact-spread is the principle route of transmission for most infections, the contribution of airborne micro-organisms to the spread of infection is likely to be greater than is currently recognised. This is partly because many airborne micro-organisms remain viable while being non-culturable, with the result that they are not detected, and also because some infections arising from contact transmission involve the airborne transportation of micro-organisms onto inanimate surfaces.

31 May 2013 in BMC Medicine
Verified
Journal Article
Open access
PDF file
Clive BeggsClive Beggs
Clive Beggs
Venous abnormalities contribute to the pathophysiology of several neurological conditions. This paper reviews the literature regarding venous abnormalities in multiple sclerosis (MS), leukoaraiosis, and normal-pressure hydrocephalus (NPH). The review is supplemented with hydrodynamic analysis to assess the effects on cerebrospinal fluid (CSF) dynamics and cerebral blood flow (CBF) of venous hypertension in general, and chronic cerebrospinal venous insufficiency (CCSVI) in particular. CCSVI-like venous anomalies seem unlikely to account for reduced CBF in patients with MS, thus other mechanisms must be at work, which increase the hydraulic resistance of the cerebral vascular bed in MS. Similarly, hydrodynamic changes appear to be responsible for reduced CBF in leukoaraiosis. The hydrodynamic properties of the periventricular veins make these vessels particularly vulnerable to ischemia and plaque formation. Venous hypertension in the dural sinuses can alter intracranial compliance. Consequently, venous hypertension may change the CSF dynamics, affecting the intracranial windkessel mechanism. MS and NPH appear to share some similar characteristics, with both conditions exhibiting increased CSF pulsatility in the aqueduct of Sylvius. CCSVI appears to be a real phenomenon associated with MS, which causes venous hypertension in the dural sinuses. However, the role of CCSVI in the pathophysiology of MS remains unclear.

7 February 2014 in Journal of Alzheimer’s Disease
Verified
Journal Article
Closed access
CCChih-Ping Chung
Chih-Ping Chung
Clive BeggsClive Beggs
Clive Beggs
PWPei-Ning Wang
Pei-Ning Wang
Niels BergslandNiels Bergsland
Niels Bergsland
SSSimon Shepherd
Simon Shepherd
RZRobert Zivadinov
Robert Zivadinov
To determine whether jugular venous reflux (JVR) is associated with cerebral white matter changes (WMCs) in individuals with Alzheimer's disease (AD), we studied 12 AD patients 24 mild cognitive impairment (MCI) patients, and 17 elderly age- and gender-matched controls. Duplex ultrasonography and 1.5T MRI scanning was applied to quantify cerebral WMCs [T2 white matter (WM) lesion and dirty-appearing-white-matter (DAWM)]. Subjects with severe JVR had more frequently hypertension (p = 0.044), more severe WMC, including increased total (p = 0.047) and periventricular DAWM volumes (p = 0.008), and a trend for increased cerebrospinal fluid volumes (p = 0.067) compared with the other groups. A significantly decreased (65.8%) periventricular DAWM volume (p = 0.01) in the JVR-positive AD individuals compared with their JVR-negative counterparts was detected. There was a trend for increased periventricular and subcortical T2 WMC lesion volumes in the JVR-positive AD individuals compared with their JVR-negative counterparts (p = 0.073). This phenomenon was not observed in either the control or MCI groups. In multiple regression analysis, the increased periventricular WMC lesion volume and decreased DAWM volume resulted in 85.7% sensitivity and 80% specificity for distinguishing between JVR-positive and JVR-negative AD patients. These JVR-WMC association patterns were not seen in the control and MCI groups. Therefore, this pilot study suggests that there may be an association between JVR and WMCs in AD patients, implying that cerebral venous outflow impairment might play a role in the dynamics of WMCs formation in AD patients, particularly in the periventricular regions. Further longitudinal studies are needed to confirm and validate our findings.

17 April 2007 in BMC Microbiology
Verified
Journal Article
Open access
PDF file
LFLouise Fletcher
Louise Fletcher
LGLindsey F Gaunt
Lindsey F Gaunt
Clive BeggsClive Beggs
Clive Beggs
SSSimon J Shepherd
Simon J Shepherd
PSP Andrew Sleigh
P Andrew Sleigh
KKKevin G Kerr
Kevin G Kerr
Background: In recent years there has been renewed interest in the use of air ionisers to control of the spread of airborne infection. One characteristic of air ions which has been widely reported is their apparent biocidal action. However, whilst the body of evidence suggests a biocidal effect in the presence of air ions the physical and biological mechanisms involved remain unclear. In particular, it is not clear which of several possible mechanisms of electrical origin (i.e. the action of the ions, the production of ozone, or the action of the electric field) are responsible for cell death. A study was therefore undertaken to clarify this issue and to determine the physical mechanisms associated with microbial cell death. Results: In the study seven bacterial species (Staphylococcus aureus, Mycobacterium parafortuitum, Pseudomonas aeruginosa, Acinetobacter baumanii, Burkholderia cenocepacia, Bacillus subtilis and Serratia marcescens) were exposed to both positive and negative ions in the presence of air. In order to distinguish between effects arising from: (i) the action of the air ions; (ii) the action of the electric field, and (iii) the action of ozone, two interventions were made. The first intervention involved placing a thin mica sheet between the ionisation source and the bacteria, directly over the agar plates. This intervention, while leaving the electric field unaltered, prevented the air ions from reaching the microbial samples. In addition, the mica plate prevented ozone produced from reaching the bacteria. The second intervention involved placing an earthed wire mesh directly above the agar plates. This prevented both the electric field and the air ions from impacting on the bacteria, while allowing any ozone present to reach the agar plate. With the exception of Mycobacterium parafortuitum, the principal cause of cell death amongst the bacteria studied was exposure to ozone, with electroporation playing a secondary role. However in the case of Mycobacterium parafortuitum, electroporation resulting from exposure to the electric field appears to have been the principal cause of cell inactivation. Conclusion: The results of the study suggest that the bactericidal action attributed to negative air ions by previous researchers may have been overestimated.

13 October 2020 in PeerJ
Verified
Journal Article
Open access
PDF file
Clive BeggsClive Beggs
Clive Beggs
Eldad AvitalEldad Avital
Eldad Avital
As the world’s economies come out of the lockdown imposed by the COVID-19 pandemic, there is an urgent need for technologies to mitigate COVID-19 transmission in confined spaces such as buildings. This feasibility study looks at one such technology, upper-room ultraviolet (UV) air disinfection, that can be safely used while humans are present in the room space, and which has already proven its efficacy as an intervention to inhibit the transmission of airborne diseases such as measles and tuberculosis. Using published data from various sources, it is shown that the SARS-CoV-2 virus, the causative agent of COVID-19, is highly likely to be susceptible to UV-C damage when suspended in air, with a UV susceptibility constant likely to be in the region 0.377–0.590 m2/J, similar to that for other aerosolised coronaviruses. As such, the UV-C flux required to disinfect the virus is expected to be acceptable and safe for upper-room applications. Through analysis of expected and worst-case scenarios, the efficacy of the upper-room UV-C approach for reducing COVID-19 transmission in confined spaces (with moderate but sufficient ceiling height) is demonstrated. Furthermore, it is shown that with SARS-CoV-2, it should be possible to achieve high equivalent air change rates using upper-room UV air disinfection, suggesting that the technology might be particularly applicable to poorly ventilated spaces.