Athoy Nilima

Dr. Athoy Nilima

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2020 in Physical Review D
Verified
Journal Article
Closed access
PDF file
DAD. S. Akerib
D. S. Akerib
SAS. Alsum
S. Alsum
HAH. M. Araújo
H. M. Araújo
XBX. Bai
X. Bai
JBJ. Balajthy
J. Balajthy
LCLUX Collaboration
LUX Collaboration
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a twofold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5  GeV/c2 WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

1 March 2020 in Astroparticle Physics
Verified
Journal Article
Closed access
DAD.S. Akerib
D.S. Akerib
CAC.W. Akerlof
C.W. Akerlof
SAS.K. Alsum
S.K. Alsum
NAN. Angelides
N. Angelides
HAH.M. Araújo
H.M. Araújo
JYJ. Yin
J. Yin

10 July 2019 in Physical Review D
Verified
Journal Article
Open access
PDF file
DAD. S. Akerib
D. S. Akerib
SAS. Alsum
S. Alsum
HAH. M. Araújo
H. M. Araújo
XBX. Bai
X. Bai
JBJon Balajthy
Jon Balajthy
LCLUX Collaboration
LUX Collaboration
We report results from an extensive set of measurements of the β-decay response in liquid xenon. These measurements are derived from high-statistics calibration data from injected sources of both H3 and C14 in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491  V/cm, and for energies ranging from 1.5 to 145 keV.

1 February 2020 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
DAD.S. Akerib
D.S. Akerib
SAS. Alsum
S. Alsum
HAH.M. Araújo
H.M. Araújo
XBX. Bai
X. Bai
JBJon Balajthy
Jon Balajthy
CZC. Zhang
C. Zhang
We report here methods and techniques for creating an improved model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the β decays of 3H and 14C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0 framework and how it can be modified to produce a final, detector-specific, electronic recoil model. This example provides the final model for LUX and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

3 January 2020 in Physical Review D
Verified
Journal Article
Open access
PDF file
DAD Akerib
D Akerib
SAS Alsum
S Alsum
HAH Araújo
H Araújo
XBX Bai
X Bai
JBJ Balajthy
J Balajthy
CZC Zhang
C Zhang
We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live−days×118  kg. Here, the calculations of the mirror electron scattering rate in liquid xenon take into account the shielding effects from mirror dark matter captured within the Earth. Annual and diurnal modulation of the dark matter flux and atomic shell effects in xenon are also accounted for. Having found no evidence for an electron recoil signal induced by mirror dark matter interactions we place an upper limit on the kinetic mixing parameter over a range of local mirror electron temperatures between 0.1 and 0.9 keV. This limit shows significant improvement over the previous experimental constraint from orthopositronium decays and significantly reduces the allowed parameter space for the model. We exclude mirror electron temperatures above 0.3 keV at a 90% confidence level, for this model, and constrain the kinetic mixing below this temperature.

11 May 2020 in Journal of Physics G: Nuclear and Particle Physics
Verified
Journal Article
Open access
PDF file
ANAthoy Nilima
Athoy Nilima
SHS Hossain
S Hossain
MAM Azad
M Azad
MBMd. Masum Billah
Md. Masum Billah
ATA Tariq
A Tariq
ABA Basak
A Basak
This work reports, for the first time, the analysis of tensor analyzing powers (T 20, T 21, T 22) along with the differential cross-section (CS) and the vector analyzing power iT 11 for the 6Li + 12C elastic scattering at 30 and 50 MeV within the framework of an optical model (OM) using microscopic shallow non-monotonic (NM) potentials. The NM potential is generated from the energy density functional formalism (EDF) (Brueckner et al (1968) Phys. Rev. 168 1184) using a realistic two-nucleon interaction incorporating the Pauli exclusion principle. The shallow NM potential can describe the experimental angular distributions of CS and analyzing powers of the elastic scattering data. The OM analysis of the data at 30 and 50 MeV does not indicate their sensitivity on the nuclear matter incompressibility K.