Ann Mattsson

Ann Mattsson


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2006 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
BWBritt-Marie Wilén
Britt-Marie Wilén
DLD. Lumley
D. Lumley
Ann MattssonAnn Mattsson
Ann Mattsson
TMTakashi Mino
Takashi Mino
The effect of rain events on effluent quality dynamics was studied at a full scale activated sludge wastewater treatment plant which has a process solution incorporating pre-denitrification in activated sludge with post-nitrification in trickling filters. The incoming wastewater flow varies significantly due to a combined sewer system. Changed flow conditions have an impact on the whole treatment process since the recirculation to the trickling filters is set by the hydraulic limitations of the secondary settlers. Apart from causing different hydraulic conditions in the plant, increased flow due to rain or snow-melting, changes the properties of the incoming wastewater which affects process performance and effluent quality, especially the particle removal efficiency. A comprehensive set of on-line and laboratory data were collected and analysed to assess the impact of rain events on the plant performance.

9 May 2017 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
Ann MattssonAnn Mattsson
Ann Mattsson
AFA. Finnson
A. Finnson
DID. I'Ons
D. I'Ons
In 2014, 25% of the sludge produced at Swedish municipal wastewater treatment plants was applied to agricultural land. Even though the Swedish heavy metal limits for sludge to be used in agriculture are amongst the most stringent in the EU, more stringent heavy metal limits are proposed. Most sludge applied to agricultural land is recycled within a certification system, Revaq. Revaq has targets for control at source management and improvement of sludge quality. Statistics based on data collected within the Revaq system was used to differentiate between local and general sources of heavy metals and assess the need to improve sludge quality. The analysis indicates that proposed future national limits on the quality of the sludge can be met by most of the sludge. The improvement needed for about 20% of the sludge is feasible through local control at source management. The levels of cadmium, copper and mercury need to be reduced if these metals are not to limit the amount of sludge that may be applied per unit area of arable land. Finally, the long term Revaq targets for cadmium and silver will be difficult to meet.

1 November 2016 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
JMJonathan Mattsson
Jonathan Mattsson
Ann MattssonAnn Mattsson
Ann Mattsson
FDFredrik Davidsson
Fredrik Davidsson
AHAnnelie Hedström
Annelie Hedström
HÖHeléne Österlund
Heléne Österlund
MVMaria Viklander
Maria Viklander
The quality of wastewater varies between catchments due to variation in urbanisation, sewer system properties, and pollution levels. This study was conducted to identify wastewater quality parameters that could be normalized to estimate levels of infiltration/inflow (I/I) in selected catchments and to investigate the geographic origins of metals entering sewer systems. Two sampling campaigns were conducted in the five catchments of the Gothenburg area focusing on 14 water quality parameters. Data from a reference study on domestic wastewater quality to normalize the mass flows associated with pure domestic wastewater was applied. The level of dilution due to I/I in wastewater entering Rya Wastewater Treatment Plant, estimated using Tot-N and Tot-P as indicators, provided the closest fit among the water quality parameters with results obtained by established methods for the two campaigns. The results from the study also indicated which catchments generated nondomestic wastewater with higher mass fl...

1 June 2012 in Water Practice & Technology
Verified
Journal Article
Closed access
PDF file
BWBritt-Marie Wilén
Britt-Marie Wilén
AJAnn Johansen
Ann Johansen
Ann MattssonAnn Mattsson
Ann Mattsson
To meet stricter effluent discharge limits of total phosphorus, microscreens can be applied for tertiary effluent treatment. The Rya WWTP has recently been upgraded with microscreens in the form of disc filters. Extensive characterisation of the wastewater from different locations in the plant (influent, after primary settling) and secondary settler effluent, was performed to increase the understanding of the potential of removing different components from the wastewater. The wastewater was fractionated by filtration through filter cloths with pore sizes 40, 20, 15, and 10 μm and through finer filters with pore size 1.2, 0.45, 0.2 and 0.1 μm. Particle size analysis (PSA) was used to assess the removal efficiency of the filter cloths. High removal degrees were achieved were particles larger or equal in size to the pore size were strained. Some floc break-up took place leading to an increased number of small particles (1–5 μm) after filtration. The suspended solids concentration could be reduced to 1 mg/l with total phosphorus concentrations of <0.2 mg/l. Some removal of metals could be observed when filtering wastewater with higher concentrations (influent and secondary settler effluent) whereas no effect could be seen for the effluent wastewater, probably due to the low concentrations present. The results from this study indicate a poor removal efficiency of pathogens measured as indicator microorganisms.

1 November 2005 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
RKR. Kjellstrand
R. Kjellstrand
Ann MattssonAnn Mattsson
Ann Mattsson
CNC. Niklasson
C. Niklasson
Mohammad J. TaherzadehMohammad J. Taherzadeh
Mohammad J. Taherzadeh
The presence of a short circuit flow in a denitrifying activated sludge tank was identified and modelled. Tracer tests with pulse addition of lithium salt were used to investigate the hydraulics of the tank. The lithium concentration in the effluent was detected and residence time distribution (RTD) curves were generated. Hydraulic models based on completely stirred tank reactors (CSTRs) in series were generated from the RTD curves and the models were compared. The short circuit problem was successfully described using the Martin model, where the inflow is divided into two strands. Each strand was modelled as a number of CSTRs in series. At a normal flow the results of the model show that the tank has 12.8% dead volume, 85.8% main volume and 1.3% short circuiting volume. The inflow was divided into 91.9% entering the main volume and 8.1% entering the short circuiting volume. The mean velocity of the short circuiting stream was estimated to 0.4m/s. At maximum flow the short circuiting stream was even larger and handled 24.3% of the flow. The short circuiting stream was identified in the upper part of the tank due to the position of the inlet and the outlet. The configuration of a tank including the use of baffles, the geometry of the inlet and mixer configuration should be considered carefully if short circuiting is to be avoided.

1 November 2012 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
Ann MattssonAnn Mattsson
Ann Mattsson
JMJ. Mattsson
J. Mattsson
FDF. Davidsson
F. Davidsson
The Swedish licensing system for wastewater sludge use in agriculture, REVAQ, sets challenges. These include a maximum nominal accumulation rate of 0.2%/year on farmland, for specified metals, to be reached by 2025. Here a model is suggested, and applied for the Gothenburg regional wastewater treatment plant, Gryaab, to quantify historic sludge quality improvements and necessary future development. Local sampling campaigns covering two decades show a substantial reduction of heavy metals and ecologically harmful organic substances (such as adsorbable organic halogens, nonylphenols, phthalates, naphthalenes and polycyclic aromatic hydrocarbons) from households and society at large. For the metals studied the historic mass flow reduction to sludge varies from 1 to 2%/year for mercury, zinc and copper to 15%/year for silver. Copper needs further reduction, involving water pipes and copper roofing. Silver is rare in soil, and significant reduction from already low levels is needed to reach the accumulation goal. Further reduction of other metals involves addressing storm- and drainage water entering the sewers and the sediments already in the sewers. Fulfilling the goals of REVAQ implies national and local measures affecting public and private stakeholders including property owners, the wastewater collection system, commercial businesses and legislating authorities.