Zhe Ji

Dr. Zhe Ji


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YJYuliang Jiang
Yuliang Jiang
ZJZhe Ji
Zhe Ji
FGFuxin Guo
Fuxin Guo
RPRan Peng
Ran Peng
HSHaitao Sun
Haitao Sun
JWJunjie Wang
Junjie Wang
For the recurrence of head and neck cancer after operation and radiotherapy, the local control of radioactive seed implantation is good, and it has a certain palliative effect. This study aims to investigate the acute and late side effects of a three-dimentional printing non co-planar template (3D–PNCT) for computed tomography (CT)-guided radioactive 125I seed (RIS) implantation in recurrent cancer of the head and neck. Between January 2016 and December 2016, forty-two patients with local recurrent malignant tumors of the head and neck received 3D–PNCT-assisted RIS implantation. The prescribed dose was 110–160 Gy. Preoperative planning design, production of individual guide plates, RIS implantation, postoperative dose evaluation, and follow-up were completed for all patients. Side effects in the skin, mucous membranes, blood and spinal cord were evaluated. All patients underwent surgery successfully. Duration of follow-up was 4–14 (median, of 8.5) months. The activity of a single RIS was 0.34–0.7 (median, 0.6) mCi. The number of RIS was 10–126 (median, 34). The number of implantation needles was 4–31 (median, 11). The mean D2cc (dose to the most exposed 2-cc volume) and D0.1cc (dose to the most exposed 0.1-cc volume) of the skin were 24.9 (7.1–85.5) and 47.5 (9.4–167.2), respectively, whereas those of the spinal cord were 8.4 (4.5–33.3) and 14.2 (13.6–63.0), mucosa were 35.1 (4.2–82.8) and 87.0 (6.6–214.1), parotid glands were 16.2 (12.8–19.7) and 29.8 (26.1–33.4) and those of the trachea were 17.9 (2.5–45.9) and 32.7 (3.9–83.9), respectively. No case had an acute reaction of grade ≥ 3. Three cases had a grade-1 skin reaction. Blood toxicity did not occur, nor spinal-cord injury. Xerostomia was not aggravated than that of before brachytherapy. One case had a grade-3 nerve response. 3D–PNCT-assisted RIS implantation can provide good accuracy for positioning. For local recurrent malignant tumor of head and neck, there were no obvious adverse reactions.

1 June 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
ZJZhe Ji
Zhe Ji
YJYuliang Jiang
Yuliang Jiang
FGFuxin Guo
Fuxin Guo
HSHaitao Sun
Haitao Sun
JFJinghong Fan
Jinghong Fan
JWJunjie Wang
Junjie Wang

19 October 2019 in Journal of Cancer Research and Clinical Oncology
Verified
Journal Article
Closed access
PDF file
ZJZhe Ji
Zhe Ji
YJYuliang Jiang
Yuliang Jiang
FGFuxin Guo
Fuxin Guo
RPRan Peng
Ran Peng
HSHaitao Sun
Haitao Sun
JWJunjie Wang
Junjie Wang

16 October 2015 in BMC Cancer
Verified
Journal Article
Open access
PDF file
LLLipin Liu
Lipin Liu
NBNan Bi
Nan Bi
ZJZhe Ji
Zhe Ji
JLJunling Li
Junling Li
JWJingbo Wang
Jingbo Wang
LWLuhua Wang
Luhua Wang
For patients with locally advanced non-small-cell lung cancer (LA-NSCLC), the role of consolidation chemotherapy (CCT) following concurrent chemoradiotherapy (CRT) is partially defined. The aim of this study was to evaluate the efficacy and toxicity of CCT. The characteristics of LA-NSCLC patients treated with curative concurrent CRT from 2001 to 2010 were retrospectively reviewed. Among 203 patients, 113 (55.7 %) patients received CCT. The median number of delivered CCT was 3 and 89.4 % patients completed ≥2 cycles. The OS was significantly better for patients in the CCT group compared with that in the non-CCT group (median OS, 27 months vs. 16 months; 5-year OS, 30.4 % vs. 22.5 %; p = 0.012). The median PFS were 12 months in the CCT group and 9 months in the non-CCT group (p = 0.291). The survival advantages of CCT were significant for males (HR: 0.63; 95 % CI, 0.44 − 0.90), patients with age < 60 years (HR: 0.63; 95 % CI, 0.42 − 0.95), non-squamous histology (HR: 0.44; 95 % CI, 0.25 − 0.76), pretreatment KPS ≥ 80 (HR: 0.67; 95 % CI, 0.48 − 0.93), stage IIIb (HR: 0.64; 95 % CI, 0.43 − 0.95), stable disease (HR: 0.31; 95 % CI, 0.14 − 0.65) and radiotherapy dose ≥ 60 Gy (HR: 0.69; 95 % CI, 0.48 − 1.00). There was no significant difference between the CCT group and the non-CCT group regarding treatment-related toxicities. CCT might further prolong survival compared with CRT alone for LA-NSCLC without increasing treatment-related toxicities, especially for males, patients with age < 60 years, non-squamous histology, pretreatment KPS ≥ 80, stage IIIb, stable disease and radiotherapy dose ≥ 60 Gy. Large size prospective investigations that incorporate patient characteristics and treatment response are warranted to validate our findings.

7 August 2017 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
ZJZhe Ji
Zhe Ji
YJYuliang Jiang
Yuliang Jiang
LSLiang Su
Liang Su
FGFuxin Guo
Fuxin Guo
RPRan Peng
Ran Peng
JWJunjie Wang
Junjie Wang
Objective: To compare dose distributions of postoperative plans with preoperative plans for radioactive seed implantation of paravertebral/retroperitoneal tumors assisted by 3-dimensional printing noncoplanar templates and computed tomography. Methods: Sixteen patients with paravertebral/retroperitoneal tumors (21 lesions) underwent radioactive seed implantation with 3-dimensional printing noncoplanar templates. Prescribed dose was 110 to 160 Gy. We compared the dose distribution of the postoperative plan with the preoperative plan. Dose parameters were D90, minimum peripheral dose, V100, V150, conformal index and external index of the target volume, and the dose received by 2 cm3 of normal tissue of organs at risk (spinal cord, aorta, and kidney). Results: Sixteen 3-dimensional printing noncoplanar templates were produced for 21 treatment areas. Mean gross tumor volume (preoperative) of patients was 61.1 cm3, mean needle number was 17, mean number of implanted 125I seeds was 65, and mean D90 of postoperative target area (gross tumor volume) was 131.1 Gy. Actual number of seeds postbrachytherapy increased by 1 to 12 in 8 cases. For postoperative plans, the mean D90, minimum peripheral dose, V100, V150 was 131.1 Gy, 67.1 Gy, 90.2%, and 64.1%, respectively, and 135.0 Gy, 64.7 Gy, 90.9%, and 64.1%, respectively, in preoperative plans. Comparing with the preplanned cases, the dose of the target volume was slightly lower and the high-dose area of the target volume was larger in postoperative cases, but the difference was not statistically significant ( P > .05). Actual dose conformity of the target volume was lower than preplanned, and the difference was statistically significant ( P = .005). Conclusion: Three-dimensional printing noncoplanar templates can provide good accuracy for positioning and direction in radioactive seed implantation.

7 July 2023 in Advances in Radiotherapy & Nuclear Medicine
Verified
Journal Article
Open access
PDF file
Suqing TianSuqing Tian
Suqing Tian
BQBin Qiu
Bin Qiu
PJPing Jiang
Ping Jiang
YJYuliang Jiang
Yuliang Jiang
ZJZhe Ji
Zhe Ji
JWJunjie Wang
Junjie Wang
Permanent I-125 seed implantation is one of the most commonly used brachytherapy (BT) forms, potentially applicable to almost any solid tumor as a standalone anti-tumor therapy or in combination with external beam radiotherapy (EBRT). The main advantage of I-125 seed implantation BT is its ability to deliver a high radiation dose within target volumes while maintaining a sharp dose drop-off profile, thereby protecting adjacent normal tissue. The clinical use of I-125 seed implantation in China has significantly increased in the past decades due to the application of an image-guided BT treatment planning system with reverse optimization capabilities and 3D printing individual template (3D-PIT) assistance. Computed tomography-guided I-125 seed implantation became a widely common modality of BT and has been used in many clinical settings for a variety of refractory cancer in China since 2002. The application has been expanded significantly not only for prostate cancer as monotherapy but also in combination with EBRT for the salvage treatment for refractory/recurrent head-and-neck carcinoma (HNC). With the assistance of 3D-PIT, since 2015, the quality control of I-125 seed implantation has been significantly adapted with high precision and real-time dose optimization. This review aims to summarize the developments and status of 3D-PIT-based I-125 seed implantation BT for the treatment of refractory HNC and standardized workflow in China.