Ramon Gonzalez-Camarena

Prof. Dr. Ramon Gonzalez-Camarena

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2000 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
RGRamon Gonzalez-Camarena
Ramon Gonzalez-Camarena
SCSalvador Carrasco-Sosa
Salvador Carrasco-Sosa
RRRubén Román-Ramos
Rubén Román-Ramos
MGMercedes J. Gaitán-González
Mercedes J. Gaitán-González
VMVerónica Medina-Bañuelos
Verónica Medina-Bañuelos
JAJoaquín Azpiroz-Leehan
Joaquín Azpiroz-Leehan
GONZÁLEZ-CAMARENA, R., S. CARRASCO-SOSA, R. ROMÁN-RAMOS, M. J. GAITÁN-GONZÁLEZ, V. MEDINA-BAÑUELOS, and J. AZPIROZ-LEEHAN. Effect of static and dynamic exercise on heart rate and blood pressure variabilities. Med. Sci. Sports Exerc., Vol. 32, No. 10, pp. 1719–1728, 2000. Purpose This study examines the effect of static and dynamic leg exercises on heart rate variability (HRV) and blood pressure variability (BPV) in humans. Methods 10 healthy male subjects were studied at rest, during static exercise performed at 30% of maximal voluntary contraction (SX30), and during dynamic cycling exercises done at 30% of V̇O2max (DX30) and at 60% of V̇O2max (DX60). Respiration, heart rate, and blood pressure signals were digitized to analyze temporal and spectral parameters involving short and overall indexes (SD, ΔRANGE, RMSSD, Total power), power of the low (LF), middle (MF), and high (HF) frequency components, and the baroreceptor sensitivity by the αMF index. Results During SX30, indexes of HRV as SD, ΔRANGE, Total power, and MF in absolute units increased in relation with rest values and were significantly higher (P < 0.001) than during DX30 and DX60; HF during SX30, in normalized and absolute units, was not different of the rest condition but was higher (P < 0.001) than HF during DX30 and DX60. Parameters of BPV as SD and ΔRANGE increased (P < 0.001) during both type of exercises, and significant (P < 0.01) increments were observed on MF during SX30 and DX30; systolic HF was attenuated during DX30 (P < 0.05), whereas diastolic HF was augmented during DX60 (P < 0.001). Compared with rest condition, the αMF index decreased (P < 0.01) only during dynamic exercises. Conclusion Because HRV and BPV response is different when induced by static or dynamic exercise, differences in the autonomic activity can be advised. Instead of the vagal withdrawal and sympathetic augmentation observed during dynamic exercise, the increase in the overall HRV and the MF component during static exercise suggest an increased activity of both autonomic branches.

1 October 2015 in Physiology & Behavior
Verified
Journal Article
Closed access
JRJosé Javier Reyes-Lagos
José Javier Reyes-Lagos
JEJuan Carlos Echeverría-Arjonilla
Juan Carlos Echeverría-Arjonilla
MPMiguel Ángel Peña-Castillo
Miguel Ángel Peña-Castillo
MGMaría Teresa García-González
María Teresa García-González
MOMaría del Rocío Ortiz-Pedroza
María del Rocío Ortiz-Pedroza
RGRamon Gonzalez-Camarena
Ramon Gonzalez-Camarena

7 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BRBersain Reyes
Bersain Reyes
NONemecio Olvera-Montes
Nemecio Olvera-Montes
SCSonia Charleston-Villalobos
Sonia Charleston-Villalobos
RGRamon Gonzalez-Camarena
Ramon Gonzalez-Camarena
MMMayra Mejía
Mayra Mejía
TATomas Aljama-Corrales
Tomas Aljama-Corrales
In this work, we present a mobile health system for the automated detection of crackle sounds comprised by an acoustical sensor, a smartphone device, and a mobile application (app) implemented in Android. Although pulmonary auscultation with traditional stethoscopes had been used for decades, it has limitations for detecting discontinuous adventitious respiratory sounds (crackles) that commonly occur in respiratory diseases. The proposed app allows the physician to record, store, reproduce, and analyze respiratory sounds directly on the smartphone. Furthermore, the algorithm for crackle detection was based on a time-varying autoregressive modeling. The performance of the automated detector was analyzed using: (1) synthetic fine and coarse crackle sounds randomly inserted to the basal respiratory sounds acquired from healthy subjects with different signal to noise ratios, and (2) real bedside acquired respiratory sounds from patients with interstitial diffuse pneumonia. In simulated scenarios, for fine crackles, an accuracy ranging from 84.86% to 89.16%, a sensitivity ranging from 93.45% to 97.65%, and a specificity ranging from 99.82% to 99.84% were found. The detection of coarse crackles was found to be a more challenging task in the simulated scenarios. In the case of real data, the results show the feasibility of using the developed mobile health system in clinical no controlled environment to help the expert in evaluating the pulmonary state of a subject.

1 May 2014 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
BRBersain Reyes
Bersain Reyes
SCSonia Charleston-Villalobos
Sonia Charleston-Villalobos
RGRamon Gonzalez-Camarena
Ramon Gonzalez-Camarena
TAT. Aljama-Corrales
T. Aljama-Corrales

Verified
Journal Article
Open access
PDF file
Arturo Flores-PliegoArturo Flores-Pliego
Arturo Flores-Pliego
Aurora Espejel-NuñezAurora Espejel-Nuñez
Aurora Espejel-Nuñez
HBHector Borboa-Olivares
Hector Borboa-Olivares
Sandra Parra HernandezSandra Parra Hernandez
Sandra Parra Hernandez
AMARACELI MONTOYA-ESTRADA
ARACELI MONTOYA-ESTRADA
GEGuadalupe Estrada-Gutierrez
Guadalupe Estrada-Gutierrez
Endothelial dysfunction (ED) in preeclampsia (PE) results from the convergence of oxidative stress, inflammation, and alterations in extracellular matrix components, affecting vascular tone and permeability. The molecular network leading to ED includes IL-8 and MMP-2. In vitro, IL-8 regulates the concentration and activity of MMP-2 in the trophoblast; this interaction has not been studied in endothelial cells during PE. We isolated human umbilical vein endothelial cells (HUVECs) from women with healthy pregnancies (NP, n = 15) and PE (n = 15). We quantified the intracellular concentration of nitric oxide and reactive oxygen species with colorimetric assays, IL-8 with ELISA, and MMP-2 with zymography and using an ELISA-type system. An IL-8 inhibition assay was used to study the influence of this cytokine on MMP-2 concentration and activity. HUVECs from women with PE showed significantly higher oxidative stress than NP. IL-8 and MMP-2 were found to be significantly elevated in PE HUVECs compared to NP. Inhibition of IL-8 in HUVECs from women with PE significantly decreased the concentration of MMP-2. We demonstrate that IL-8 is involved in the mechanisms of MMP-2 expression in HUVECs from women with PE. Our findings provide new insights into the molecular mechanisms regulating the ED distinctive of PE.

1 January 2013 in Methods of Information in Medicine
Verified
Journal Article
Closed access
PDF file
LAL. Albuerne-Sanchez
L. Albuerne-Sanchez
RGRamon Gonzalez-Camarena
Ramon Gonzalez-Camarena
MMM. Mejia-Avila
M. Mejia-Avila
GCG Carrillo-Rodriguez
G Carrillo-Rodriguez
TATomas Aljama-Corrales
Tomas Aljama-Corrales
SCSonia Charleston-Villalobos
Sonia Charleston-Villalobos
Summary: Objective: Pulmonary disorders are frequently characterized by the presence of adventitious sounds added to the breathing or base lung sound (BLS). The aim of this work was to assess the features of BLS in extrinsic allergic alveolitis (EAA) patients in comparison to healthy subjects, applying linear and nonlinear analysis techniques.Methods: We investigated the multichannel lung sounds on the posterior chest of 16 females, 8 healthy and 8 EAA patients, when breathing at 1.5 L/s. BLS linear features were obtained from the power spectral density (PSD) while nonlinear features were extracted by the concepts of irregularity and complexity, i.e., spectral, sample and multi-scale entropy.Results: The results demonstrated that spectral percentiles of BLS were lower in EAA patients than in healthy subjects but statistical significance (p<0.05) was obtained only for expiration at the left apical and both basal regions. Also, the maximum amplitude of the PSD in patients reached statistical significance ( p < 0.05) for the expiratory phase at basal regions. In the case of nonlinear techniques, significant lower values ( p < 0.05) were obtained for EAA patients during both respiratory phases at left apical and both basal regions.Conclusion: In conclusion, we found that BLS in chronic EAA patients is characterized by lower spectral percentiles, lower irregularity and lower complexity than in healthy subjects suggesting the feasibility of its clinical usefulness by screening its temporal alteration.