Tae Wuk Bae

Dr. Tae Wuk Bae

Electronics and Telecommunications Research Institute (ETRI)
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Infrared Physics & Technology
Verified
Journal Article
Closed access
TBTae Wuk Bae
Tae Wuk Bae

29 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TBTae Wuk Bae
Tae Wuk Bae
SLSang Hag Lee
Sang Hag Lee
KKKee Koo Kwon
Kee Koo Kwon
With the advancement of the Internet of Medical Things technology, many vital sign-sensing devices are being developed. Among the diverse healthcare devices, portable electrocardiogram (ECG) measuring devices are being developed most actively with the recent development of sensor technology. These ECG measuring devices use different sampling rates according to the hardware conditions, which is the first variable to consider in the development of ECG analysis technology. Herein, we propose an R-point detection method using an adaptive median filter based on the sampling rate and analyze major arrhythmias using the signal characteristics. First, the sliding window and median filter size are determined according to the set sampling rate, and a wider median filter is applied to the QRS section with high variance within the sliding window. Then, the R point is detected by subtracting the filtered signal from the original signal. Methods for detecting major arrhythmias using the detected R point are proposed. Different types of ECG signals were used for a simulation, including ECG signals from the MIT-BIH arrhythmia database and MIT-BIH atrial fibrillation database, signals generated by a simulator, and actual measured signals with different sampling rates. The experimental results indicated the effectiveness of the proposed R-point detection method and arrhythmia analysis technique.

TBTae Wuk Bae
Tae Wuk Bae
MKMin Seong Kim
Min Seong Kim
JPJong Won Park
Jong Won Park
KKKee Koo Kwon
Kee Koo Kwon
KKKyu Hyung Kim
Kyu Hyung Kim
Intradialytic hypotension (IDH) is a common side effect that occurs during hemodialysis and poses a great risk for dialysis patients. Many studies have been conducted so far to predict IDH, but most of these could not be applied in real-time because they used only underlying patient information or static patient disease information. In this study, we propose a multilayer perceptron (MP)-based IDH prediction model using heart rate (HR) information corresponding to time-series information and static data of patients. This study aimed to validate whether HR differences and HR slope information affect real-time IDH prediction in patients undergoing hemodialysis. Clinical data were collected from 80 hemodialysis patients from 9 September to 17 October 2020, in the artificial kidney room at Yeungnam University Medical Center (YUMC), Daegu, South Korea. The patients typically underwent hemodialysis 12 times during this period, 1 to 2 h per session. Therefore, the HR difference and HR slope information within up to 1 h before IDH occurrence were used as time-series input data for the MP model. Among the MP models using the number and data length of different hidden layers, the model using 60 min of data before the occurrence of two layers and IDH showed maximum performance, with an accuracy of 81.5%, a true positive rate of 73.8%, and positive predictive value of 87.3%. This study aimed to predict IDH in real-time by continuously supplying HR information to MP models along with static data such as age, diabetes, hypertension, and ultrafiltration. The current MP model was implemented using relatively limited parameters; however, its performance may be further improved by adding additional parameters in the future, further enabling real-time IDH prediction to play a supporting role for medical staff.

2 October 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TBTae Wuk Bae
Tae Wuk Bae
KKKee Koo Kwon
Kee Koo Kwon
Recently, with the active development of wearable electrocardiogram (ECG) devices such as smart-bands or portable ECG devices, efficient ECG signal processing technology that can be applied in real-time has been actively studied. However, a wearable ECG device is exposed to various noise situations, thereby reducing the reliability of the detected R point or QRS interval. In addition, as early warning techniques in healthcare systems have been studied, real-time ECG signal processing techniques have become very important in wearable ECG devices. In this paper, we propose an efficient real-time R and QRS detection method using two kinds of first-order derivative filters and a max filter to analyze ECG signals measured from wearable ECG devices in real-time. The proposed method detects the R point and QRS interval in units of a sliding window for real-time processing and combines the detected R points in each sliding window. Also, the reliability of the detected R points and RR intervals is examined through noise region analysis using the histogram characteristic of a sample point. The performance of the proposed method was verified by the MIT-BIH database (DB), CYBHi DB and real ECG data measured from the developed wearable ECG patch. The proposed method achieves Se = 99.80%, +P = 99.80%, and DER = 0.36% against MIT-BIH DB. In addition, the proposed method enables accurate R point detection and heart rate variability (HRV) analysis even with noisy ECG signals.

29 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TBTae Wuk Bae
Tae Wuk Bae
YKYoungchoon Kim
Youngchoon Kim
SASangho Ahn
Sangho Ahn
Military infrared (IR) imaging systems utilize one or more IR wavelength-bands, among short wavelength IR (SWIR), middle wavelength IR (MWIR), and long wavelength IR (LWIR) band. The IR image wavelength-band conversion which transforms one arbitrary IR wavelength-band image to another IR wavelength-band image is needed for IR signature modeling and image synthesis in the IR systems. However, the IR wavelength-band conversion is very challenging because absorptivity and transmittance of objects and background (atmosphere) are different according to the IR wavelength band and because radiation and reflectance characteristics of the SWIR are very different from the LWIR and MWIR. Therefore, the IR wavelength-band conversion in this paper applies to only IR targets and monotonous backgrounds at a long distance for military purposes. This paper proposes an IR wavelength-band conversion method which transforms one arbitrary IR wavelength-band image to another IR wavelength-band image by using the surface temperature estimation of an object and the error attenuation method for the estimated temperature. The surface temperature of the object is estimated by an approximated Planck’s radiation equation and the error of estimated temperature is corrected by using the slope information of exact radiance along with the approximated one. The corrected surface temperature is used for generating another IR wavelength-band image. The verification of the proposed method is demonstrated through the simulations using actual IR images obtained by thermal equipment.

13 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TBTae Wuk Bae
Tae Wuk Bae
JHJinhyun Han
Jinhyun Han
KKKuk Jin Kim
Kuk Jin Kim
YKYoung Taeg Kim
Young Taeg Kim
Commercial visibility sensors among meteorological sensors estimate the visibility distance based on transmission, backward scattering, and forward scattering principle. These optical visibility sensors yield comparatively accurate local visibility distance. However, it is still difficult to obtain comprehensive visibility information for a wide area, such as the coast or harbor due to the sensor structure using straightness and scattering properties of light. In this paper, we propose a novel visibility distance estimation method using dark channel prior (DCP) and distance map based on a camera image. The proposed method improves the local limit of optical visibility sensor and detects the visibility distance of a wide area more precisely. First, the dark channel for an input sea-fog image is calculated. The binary transmission image is obtained by applying a threshold to the estimated transmission from the dark channel. Then, the sum of the distance values of pixels, corresponding to the sea-fog boundary, is averaged, in order to derive the visibility distance. This paper also proposes a novel air-light and transmission estimation technique in order to extract the visibility distance for an abnormal sea-fog image, including any light source, such as sunlight, reflection light, and illumination light, etc. The estimated visibility distance was compared with optical visibility distance of an optical visibility sensor and their agreement was evaluated.