CHAO TAO

Prof. Dr. CHAO TAO

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2012 in Applied Physics Letters
Verified
Journal Article
Closed access
YYYiqun Yang
Yiqun Yang
SWShaohua Wang
Shaohua Wang
CTCHAO TAO
CHAO TAO
XWXueding Wang
Xueding Wang
XLXiaojun Liu
Xiaojun Liu
Based on the analyzed relationship between the microstructure and the spectral parameters of photoacoustic signal, a tomography scheme with a narrowband and low frequency is designed to evaluate the subwavelength microstructure of tissues. Experiments show that this approach can differentiate the subwavelength microstructures of two melanomas-like samples, where their structure scales (49 and 199 μm) are much smaller than the working wavelength 0.3–1.5 mm of the imaging system. Since the microstructure is an effective indicator to tissue characteristics, the proposed imaging scheme could have the potential to classify different tissue types and achieve improved diagnosis in deep tissues.

23 February 2016 in Scientific Reports
Verified
Journal Article
Open access
RCRenxiang Cheng
Renxiang Cheng
JSJiaojiao Shao
Jiaojiao Shao
XGXiaoxiang Gao
Xiaoxiang Gao
CTCHAO TAO
CHAO TAO
JGJiuyu Ge
Jiuyu Ge
XLXiaojun Liu
Xiaojun Liu
Dental hard tissue lesions, including caries, cracked-tooth, etc., are the most prevalent diseases of people worldwide. Dental lesions and correlative diseases greatly decrease the life quality of patients throughout their lifetime. It is still hard to noninvasively detect these dental lesions in their early stages. Photoacoustic imaging is an emerging hybrid technology combining the high spatial resolution of ultrasound in deep tissue with the rich optical contrasts. In this study, a dual-contrast photoacoustic tomography is applied to detect the early dental lesions. One contrast, named B-mode, is related to the optical absorption. It is good at providing the sharp image about the morphological and macro-structural features of the teeth. Another contrast, named S-mode, is associated with the micro-structural and mechanical properties of the hard tissue. It is sensitive to the change of tissue properties induced by the early dental lesions. Experiments show that the comprehensive analysis of dual-contrast information can provide reliable information of the early dental lesions. Moreover, the imaging parameter of S-mode is device-independent and it could measure tissue properties quantitatively. We expect that the proposed scheme could be beneficial for improving safety, accuracy and sensitivity of the clinical diagnosis of the dental lesion.

9 March 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
XGXiaoxiang Gao
Xiaoxiang Gao
CTCHAO TAO
CHAO TAO
XWXueding Wang
Xueding Wang
XLXiaojun Liu
Xiaojun Liu
We analyze photo-acoustic signals from capillaries and theoretically demonstrate the quantitative relationship between vascular diameter and spectral slope in a low-frequency band. Phantom experiments validate the theoretical analysis. Based on this finding, spectral slope is proposed as the imaging parameter of a photo-acoustic microscopy. This system effectively quantifies the microvasculature with diameters of 60 and 150 μm, which are smaller than the wavelength 342 μm at the central frequency 4.39 MHz of ultrasound transducer. The low frequency also guarantees the imaging depth in the order of centimeters. The proposed scheme could be potential for noninvasive diagnosis of diseases related to abnormal vasoconstriction or angiectasis.

9 July 2015 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SWShaohua Wang
Shaohua Wang
CTCHAO TAO
CHAO TAO
YYYiqun Yang
Yiqun Yang
XWXueding Wang
Xueding Wang
XLXiaojun Liu
Xiaojun Liu
Photoacoustic imaging is an emerging technique which inherits the merits of optical imaging and ultrasonic imaging. However, classical photoacoustic imaging mainly makes use of the time-domain parameters of signals. In contrast to previous studies, we theoretically investigate the spectral characteristics of the photoacoustic signal from stochastic distributed particles. The spectral slope is extracted and used for describing the spectral characteristics of the photoacoustic signal. Both Gaussian and spherical distributions of optical absorption in particles are considered. For both situations, the spectral slope is monotonically decreased with the increase of particle size. In addition, the quantitative relationship between the spectral slope and the imaging system factors, including the laser pulse envelope, directivity of ultrasound transducer, and signal bandwidth, are theoretically analyzed. Finally, an idealized phantom experiment is performed to validate the analyses and examine the instrument independent of the spectral slope. This work provides a theoretical framework and new experimental evidence for spectrum analysis of the photoacoustic signal. This could be helpful for quantitative tissue evaluation and imaging based on the spectral parameters of the photoacoustic signal.

30 January 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
XGXiaoxiang Gao
Xiaoxiang Gao
CTCHAO TAO
CHAO TAO
XLXiaojun Liu
Xiaojun Liu
XWXueding Wang
Xueding Wang
Noncontact evaluation of elastic properties of a microstructure is still a challenge in turbid media. In this Letter, we present the observation of a phenomenon—the photoacoustic eigen-spectrum from light-absorbing objects. Analysis and experiments demonstrate that the eigen-vibration information of a microstructure is imprinted in its photoacoustic coda waves after it is exposed to a laser pulse illumination. The spectral lines in the time-frequency map of photoacoustic coda waves correspond to the eigen-frequencies of the light-absorber. This phenomenon provides a physical basis for noncontact evaluation of elastic properties of a microstructure in turbid media. Elastic parameters can be accurately inversed from the measured photoacoustic eigen-spectrum.

8 March 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
QDQiuning Ding
Qiuning Ding
CTCHAO TAO
CHAO TAO
XLXiaojun Liu
Xiaojun Liu
Speed-of-sound and optical absorption reflect the structure and function of tissues from different aspects. A dual-mode microscopy system based on a concentric annular ultrasound array is proposed to simultaneously acquire the long depth-of-field images of speed-of-sound and optical absorption of inhomogeneous samples. First, speed-of-sound is decoded from the signal delay between each element of the annular array. The measured speed-of-sound could not only be used as an image contrast, but also improve the resolution and accuracy of spatial location of photoacoustic image in inhomogeneous acoustic media. Secondly, benefitting from dynamic focusing of annular array and the measured speed-of-sound, it is achieved an advanced acoustic-resolution photoacoustic microscopy with a precise position and a long depth-of-field. The performance of the dual-mode imaging system has been experimentally examined by using a custom-made annular array. The proposed dual-mode microscopy might have the significances in monitoring the biological physiological and pathological processes.