With transistors scaling down, aging effects become increasingly significant in circuit design. Thus, the aging-aware cell timing model is necessary for evaluating the aging-induced delay degradation and their impact on circuit performance. However, the tradeoff between accuracy and efficiency becomes a bottleneck in traditional methods. In this brief, we propose a fast and accurate aging-aware cell timing model via graph learning. The information of multi-typed devices on different arcs can be embedded by heterogeneous graph attention networks (HGAT) and the embedded results help improve the accuracy of our aging-aware timing model. The experimental results indicate the proposed timing model can achieve high accuracy efficiently.
The high-power handling capacity of a capacitive microelectromechanical systems (MEMS) power sensor is investigated in this paper. The power sensor is designed for a parallel-plate structure with clamped-clamped beam in X-band (8-12 GHz) applications. The fabrication of this device adopts GaAs monolithic microwave integrated circuit process and MEMS technology. Experiments show that the output response of this sensor is non-linear at high power levels. To analyze this characteristic, the relevant discussion and simulation are given. First, the structure of the sensor is simulated by ANSYS HFSS software to determine the effective sensing region. Then, the mechanical behavior of the sensor analyzed by using the finite element software ANSYS. Through reasonable hypothesis, an electro-mechanical model is proposed. The model considers two effects: 1) the mode shape of the beam and 2) the signal reflection. The calculated results using this model are in good agreement with the measured ones. It indicates the impedance mismatching of the device mainly causes the non-linear response of capacitive power sensor under high-power signal.
13 January 2020 in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
Performance failure has become a major threat for various memory and analog circuits. It is challenging to estimate the extremely small failure probability when failed samples are distributed in multiple disjoint regions. In this paper, we propose an adaptive importance sampling (AIS) algorithm. AIS has several iterations of sampling region adjustments, while existing methods pre-decide a static sampling distribution. We design two adaptive frameworks based on Resampling and population Metropolis-Hastings (MH) to iteratively search for failure regions. The experimental results of AIS method exhibit better efficiency and higher accuracy. For SRAM bit cell with single failure region, AIS method uses 2-27× fewer samples and reaches better accuracy when compared to several recent methods. For a two-stage amplifier circuit with multiple failure regions, AIS method is 90× faster than Monte Carlo and 7-23× over other methods. For charge pump circuit and C2MOS master-slave latch circuit, AIS method can reach 6-18× and 4-6× speedup over other methods, respectively.
17 May 2023 in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
In advanced technology nodes, aging effects like negative and positive bias temperature instability (NBTI and PBTI) become increasingly significant, making timing closure and optimization more challenging. Unfortunately, conventional critical path (CP) selection tools used in reliability-aware design flow cannot accurately identify CPs under different aging conditions. To address this issue, we propose an aging-aware CP selection flow comprising two parts: 1) critical cell detection and 2) path criticality (PC) computation. We employ graph-attention (GAT) networks to predict the critical cells in the aged circuits, and a PC computation algorithm that takes into account circuit-level and transistor-level parameters to generate PC rank lists. Our experimental results demonstrate that our GAT model outperforms classical machine learning models in detecting critical cells. Additionally, compared with the commercial tool, our aging-aware flow achieves an average accuracy of 99.52%, 98.69%, and 97.20% for top-10%, top-5%, and top-1% path sets, respectively, in five industrial designs subjected to different aging conditions and workloads.
A dual-channel amplitude demodulator based on a micro-electromechanical systems (MEMS) approach for radio relay station on-line detection is proposed in this letter. This MEMS demodulator adopts a clamped-clamped beam to couple part of the signal from the main line to dual channels for on-line amplitude demodulation. The MEMS-based demodulation applies the square law of the thermal converter. The fabrication of the device is compatible with GaAs monolithic microwave integrated circuit process. Experiments show that the on-line MEMS demodulator has a return loss that is better than 20 dB, and an insertion loss of less than 0.5 dB up to 10 GHz. This design can realize direct demodulation of an amplitude modulation signal with a carrier frequency of 0.01-10 GHz.
9 March 2022 in IEEE Transactions on Circuits and Systems II: Express Briefs
Accurate standard cell modeling is significant for circuit timing analysis and yield estimation. With voltage decreasing to near-threshold, cell delay distribution becomes asymmetrical and has a longer tail due to various process variation effects. In this brief, we propose a novel statistical model to fit the shape of the cell delay by using log-extended-skew-normal (LESN) distribution. It estimates the values of mean, standard deviation, and $3\sigma $ delay precisely by matching the kurtosis of the cell delay distribution. By changing the parameters of the LESN model, it can be used for up to the normal voltage region (1.1V) and down to the sub-threshold voltage region (0.4V). Considering the effect of load capacitances, the parameters of LESN distribution are further modeled so that the model can be used for different fanout constraints. Tested by INV, NAND2, and NOR2 with 28 nm technology, the average error of estimating the skewness is less than 6%, while the error for the kurtosis is less than 4%. Meanwhile, the average errors of $-3\sigma $ and $+3\sigma $ delay estimation are about 1.27% and 1.82% from 0.4V to 1.1V, respectively.