Guided bone regeneration (GBR) technique is widely used in the treatment of bone defects caused by peri-implantitis, periodontal disease, etc. However, the GBR membranes commonly used in clinical treatments currently have no antibacterial activity. Therefore, in this study, sequential layer-by-layer electrospinning and electrospraying techniques were utilized to prepare a gelatin (Gln) and chitosan (CS) composite GBR membrane containing hydroxyapatite nanoparticles (nHAp) and antimicrobial peptide (Pac-525)-loaded PLGA microspheres (AMP@PLGA-MS), which was supposed to have osteogenic and antibacterial activities. The scanning electron microscope (SEM) observation showed that the morphology of the nanofibers and microspheres could be successfully produced. The diameters of the electrospun fibers with and without nHAp were 359 ± 174 nm and 409 ± 197 nm, respectively, and the mechanical properties of the membrane were measured according to the tensile stress-strain curve. Both the involvement of nHAp and the chemical crosslinking were able to enhance their tensile strength. In vitro cell culture of rat bone marrow mesenchymal stem cells (rBMSCs) indicated that the Gln/CS composite membrane had an ideal biocompatibility with good cell adhesion, spreading, and proliferation. In addition, the Gln/CS membrane containing nHAp could promote osteogenic differentiation of rBMSCs. Furthermore, according to the in vitro drug release assay and antibacterial experiments, the composite GBR membrane containing AMP@PLGA-MS exhibited a long-term sustained release of Pac-525, which had bactericidal activity within one week and antibacterial activity for up to one month against two kinds of bacteria, S. aureus and E. coli. Our results suggest that the antimicrobial peptide-loaded Gln/CS composite membrane (AMP@PLGA-MS@Gln/CS/nHAp) has a great promise in bone generation-related applications for the unique functions of guiding bone regeneration and inhibiting bacterial infection as well.
Tumor-derived exosomes are actively involved in cancer progression and metastasis and have emerged as a promising marker for cancer diagnosis in liquid biopsy. Because of their nanoscale size, complex biogenesis, and methodological limitations related to exosome isolation and detection, advancements in their analysis remain slow. Microfluidic technology offers a better analytic approach compared with conventional methods. Here, we developed a bead-based microarray for exosome isolation and multiplexed tumor marker detection. Using this method, exosomes are isolated by binding to antibodies on the bead surface, and tumor markers on the exosomes are detected through quantum dot (QD) probes. The beads are then uniformly trapped and queued among micropillars in the chip. This design benefits fluorescence observation by dispersing the signals into every single bead, thereby avoiding optical interference and enabling more accurate test results. We analyzed exosomes in the cell culture supernatant of lung cancer and endothelial cell lines, and different lung cancer markers labeled with three QD probes were used to conduct multiplexed detection of exosome surface protein markers. Lung cancer-derived samples showed much higher (~ sixfold–tenfold) fluorescence intensity than endothelial cell samples, and different types of lung cancer samples showed distinctive marker expression levels. Additionally, using the chip to detect clinical plasma samples from cancer patients showed good diagnostic power and revealed a well consistency with conventional tests for serological markers. These results provide insight into a promising method for exosome tumor marker detection and early-stage cancer diagnosis.
The repair of infective bone defects is a great challenge in clinical work. It is of vital importance to develop a kind of bone scaffold with good osteogenic properties and long-term antibacterial activity for local anti-infection and bone regeneration. A porous mineralized collagen (MC) scaffold containing poly(d,l-lactide-co-glycolic acid) (PLGA) microspheres loaded with two antibacterial synthetic peptides, Pac-525 or KSL-W was developed and characterized via scanning electron microscopy (SEM), porosity measurement, swelling and mechanical tests. The results showed that the MC scaffold embedded with smooth and compact PLGA microspheres had a positive effect on cell growth and also had antibacterial properties. Through toxicity analysis, cell morphology and proliferation analysis and alkaline phosphatase evaluation, the antibacterial scaffolds showed excellent biocompatibility and osteogenic activity. The antibacterial property evaluated with Staphylococcus aureus and Escherichia coli suggested that the sustained release of Pac-525 or KSL-W from the scaffolds could inhibit the bacterial growth aforementioned in the long term. Our results suggest that the antimicrobial peptides-loaded MC bone scaffold has good antibacterial and osteogenic activities, thus providing a great promise for the treatment of infective bone defects.
The gingival epithelium–capillary interface is a unique feature of periodontal soft tissue, preserving periodontal tissue homeostasis and preventing microorganism and toxic substances from entering the subepithelial tissue. However, the function of the interface is disturbed in periodontitis, and mechanisms of the breakdown of the interface are incompletely understood. To address these limitations, we developed a microfluidic epithelium–capillary barrier with a thin culture membrane (10 μm) that closely mimics the in vivo gingival epithelial barrier with an immune micro-environment. To test the validity of the fabricated gingival epithelial barrier model, epithelium–capillary interface-on-a-chip was cultured with human gingival epithelial cells (HGECs) and human vascular endothelial cells (HUVEC). Their key properties were tested using optical microscope, transepithelial/transendothelial electrical resistance (TEER), and permeability assays. The clear expression of VE-cadherin revealed the tight junctions in endothelial cells. Live/dead assays indicated a high cell viability, and the astrocytic morphology of HGE cells was confirmed by F-actin immunostaining. By the third day of cell culture, TEER levels typically exceeded in co-cultures. The resultant permeability coefficients showed a significant difference between 70 kDa and 40 kDa FITC-dextran. The expression of protein intercellular cell adhesion molecule (ICAM-1) and human beta defensin-2 (HBD2) decreased when exposed to TNF-α and LPS, but recovered with the NF-κB inhibitor treatment- Pyrrolidinedithiocarbamic acid (PDTC), indicating the stability of the fabricated chip. These results demonstrate that the developed epithelium-capillary interface system is a valid model for studying periodontal soft tissue function and drug delivery.
A microfluidic chip has been integrated with a capacitive biosensor based on mass-producible three-dimensional (3D) interdigital electrode arrays. To achieve the monitoring of biosensor preparation and cardiac- and periodontitis-related biomarkers, all the processes were detected in a continuously on-site way. Fabrication steps for the microfluidic chip-bonded 3D interdigital capacitor biosensor include gold thiol modification, the activation of EDC/sulfo-NHS, and the bioconjugation of antibodies. Fluorescent characterization and X-ray photoelectron spectroscopy analysis were applied to assess the successful immobilization of the C-reactive protein (CRP) antibody. The experimental results indicate the good specificity and high sensitivity of the microfluidic integrated 3D capacitive biosensor. The limit of detection of the 3D capacitive biosensor for CRP label-free detection was about 1 pg mL−1. This 3D capacitive biosensor with integrated microfluidics is mass-producible and has achieved the on-site continuous detection of cardiac- and periodontitis-related biomarkers with high performance.
20 March 2020 in Frontiers in Bioengineering and Biotechnology
Accumulating evidence showed that Interleukin (IL) level is associated with Osteoporosis. Whereas, most of these associations are based on observational studies. Thus, their causality was still unclear. Mendelian randomization (MR) is a widely used statistical framework that uses genetic instrumental variables (IVs) to explore the causality of intermediate phenotype with disease. To classify their causality, we conducted a MR analysis to investigate the effect of IL-18 level on the risk of Osteoporosis. First, based on summarized genome-wide association study (GWAS) data, 8 independent IL-18 SNPs reaching genome-wide significance were deemed as IVs. Next, Simple median method was used to calculate the pooled odds ratio (OR) of these 8 SNPs for the assessment of IL-8 on the risk of Osteoporosis. Then, MR-Egger regression was utilized to detect potential bias due to the horizontal pleiotropy of these IVs. As a result of simple median method, we get the SE (−0.001; 95% CI−0.002 to 0; P = 0.042), which means low IL-18 level could increases the risk of the development of Osteoporosis. The low intercept (0; 95% CI −0.001 to 0; P = 0.59) shows there is no bias due to the horizontal pleiotropy of the IVs.