Seon Tae Kim

Dr. Seon Tae Kim

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
ASAleksandr Shkatulov
Aleksandr Shkatulov
SKSeon Tae Kim
Seon Tae Kim
HMH. Miura
H. Miura
YKY. Kato
Y. Kato
YAYuri Aristov
Yuri Aristov

1 September 2011 in Progress in Nuclear Energy
Verified
Journal Article
Closed access
SKSeon Tae Kim
Seon Tae Kim
JRJunichi Ryu
Junichi Ryu
YKYukitaka Kato
Yukitaka Kato

1 January 2013 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SKSeon Tae Kim
Seon Tae Kim
JRJunichi Ryu
Junichi Ryu
YKYukitaka Kato
Yukitaka Kato

1 January 2019 in Energy and Buildings
Verified
Journal Article
Closed access
AAAwasthi Abhishek
Awasthi Abhishek
BKBinit Kumar
Binit Kumar
MKMin Ho Kim
Min Ho Kim
YLYong Tae Lee
Yong Tae Lee
JCJae Dong Chung
Jae Dong Chung
KLKeunhui Lee
Keunhui Lee

1 November 2016 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
WSWoo Hong Sang
Woo Hong Sang
YLYong Tae Lee
Yong Tae Lee
JCJae Dong Chung
Jae Dong Chung
SKSeon Tae Kim
Seon Tae Kim
TKTaehun Kim
Taehun Kim
KLKeun-Hui Lee
Keun-Hui Lee

7 August 2023 in Energy Science & Engineering
Verified
Journal Article
Open access
SKSeon Tae Kim
Seon Tae Kim
RHRobert Hegner
Robert Hegner
GÖGöksel Özuylasi
Göksel Özuylasi
PSPanagiotis Stathopoulos
Panagiotis Stathopoulos
ENEberhard Nicke
Eberhard Nicke
High‐temperature heat pumps (HTHPs) that can supply heat at temperatures at and above 200°C have the potential to increase energy efficiency and decrease carbon dioxide (CO2) emissions in industrial processes. In this study, three reversed Rankine cycles using water vapor (R‐718) as the working medium, with different intercooling strategies, were proposed and their performance has been investigated. The thermodynamic performance was estimated under different operating conditions, and the optimal pressure ratio (PR) between compression stages was found to be where both compressors had the same PR. The thermodynamic efficiency, φ, and exergy efficiency, ηexergy, were also analyzed at the optimum PR. The cycles that employed an intercooler between the first and second compression stages (IC cycles) showed higher φ and ηexergy values compared with the spray‐injection cycle. Among the IC cycles, the IC‐in cycle, with an inward flow direction of heat sink to the IC, demonstrated higher efficiency and deliverable temperature, Tsink out, than the spray‐injection and IC‐out cycles. To assess the practical impact of the HTHP cycles on industrial CO2 reduction, the PR for each stage was limited to 2.5. Theoretically, the IC‐in cycle could achieve a coefficient of performance of 5.86 with a Tsink out of 200°C or higher when Tevap and Tcond were at 90°C and 150°C, respectively. Additionally, the study demonstrated that the proposed HTHP system has the potential to reduce CO2 emissions by 8.1% in 2030 for industrial heat supply at temperature up to 200°C, by replacing existing industrial fossil boilers with high‐efficiency HTHP.