The European Space Agency's Planck satellite, launched on 14 May 2009, is the third-generation space experiment in the field of cosmic microwave background (CMB) research. It will image the anisotropies of the CMB over the whole sky, with unprecedented sensitivity ( ~ 2 × 10-6) and angular resolution (~5 arcmin). Planck will provide a major source of information relevant to many fundamental cosmological problems and will test current theories of the early evolution of the Universe and the origin of structure. It will also address a wide range of areas of astrophysical research related to the Milky Way as well as external galaxies and clusters of galaxies. The ability of Planck to measure polarization across a wide frequency range (30-350 GHz), with high precision and accuracy, and over the whole sky, will provide unique insight, not only into specific cosmological questions, but also into the properties of the interstellar medium. This paper is part of a series which describes the technical capabilities of the Planck scientific payload. It is based on the knowledge gathered during the on-ground calibration campaigns of the major subsystems, principally its telescope and its two scientific instruments, and of tests at fully integrated satellite level. It represents the best estimate before launch of the technical performance that the satellite and its payload will achieve in flight. In this paper, we summarise the main elements of the payload performance, which is described in detail in the accompanying papers. In addition, we describe the satellite performance elements which are most relevant for science, and provide an overview of the plans for scientific operations and data analysis.
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA programme dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100–850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art indium phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front end is cooled to 20 K for optimal sensitivity and the reference loads are cooled to 4 K to minimise low-frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements, and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical, and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
The PLANCK mission of the European Space Agency is devoted to produce sky maps of the cosmic microwave background radiation. The low-frequency instrument is a wide-band cryogenic microwave radiometer array operating at 30, 44, and 70 GHz. The design, test techniques, and performance of the complete differential radiometer at 30 GHz are presented. This elegant breadboard 30-GHz radiometer is composed of a front-end module (FEM) assembled at the Jodrell Bank Observatory, Cheshire, U.K., and a back-end module assembled at the Universidad de Cantabria, Cantabria, Spain, and Telecomunicacio/spl acute/, Universitat Polite/spl acute/cnica de Catalunya, Barcelona, Spain. The system noise temperature was excellent, mainly due to the very low noise performance of the FEM amplifiers, which achieved an average noise temperature of 9.4 K.
10 May 2004 in IEEE Microwave and Wireless Components Letters
A new harmonic-balance technique for the analysis and synthesis of coupled-oscillator systems with adjustable phase progression is presented here. It allows an accurate determination of the phase-shift versus the tuning elements, since detailed models are used for the individual oscillator circuits. It is also possible to impose the synchronization frequency at which the in-phase oscillation takes place and calculate the values of the tuning elements for a pre-fixed phase distribution. The phase noise of the system is analyzed through the carrier modulation approach. The phase-change rapidity versus a control voltage is analyzed through the envelope-transient method. A four-element oscillator array at 5 GHz has been designed through this method and experimentally characterized obtaining very good agreement with the simulation results.
We present the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our optimal pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f stability and rejection of instrumental systematic effects; its measured noise performance shows that LFI is the most sensitive instrument of its kind. The calibration parameters will be updated during flight operations until the end of the mission.