Douglas Duckworth

Dr. Douglas Duckworth


Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2005 in Separation Science and Technology
Verified
Journal Article
Closed access
RBRuth E. Baltus
Ruth E. Baltus
RCRobert M. Counce
Robert M. Counce
BCBenjamin H. Culbertson
Benjamin H. Culbertson
HLHuimin Luo
Huimin Luo
DDDavid W. DePaoli
David W. DePaoli
DDDouglas Duckworth
Douglas Duckworth
Ionic liquids have received increasing interest in recent years for “green” synthesis and separations because they have essentially no vapor pressure. We have begun an investigation of the potential of ionic liquids for gas separations, including the removal of carbon dioxide from stack gas generated in coal‐fired power plants. In this paper, we report results from measurements of the permeance of nitrogen and carbon dioxide in supported ionic liquid membranes. Preliminary results for a porous alumina membrane saturated with 1‐butyl‐3‐methyl imidazolium bis[trifluoromethylsulfonyl] amide yielded a CO2∶N2 selectivity of 127. Using previously reported measurements of CO2 solubility in ionic liquids 1 and the measured membrane transport characteristics, a preliminary economic analysis of a separation process based on supported ionic liquid membranes has been performed. A comparison of cost estimates for this membrane‐based separation to cost estimates reported for carbon dioxide removal using a conv...

1 September 1989 in Analytical Chemistry
Verified
Journal Article
Closed access
DDDouglas Duckworth
Douglas Duckworth
RMR. Kenneth. Marcus
R. Kenneth. Marcus

27 January 2004 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
GJGlen P. Jackson
Glen P. Jackson
DDDouglas Duckworth
Douglas Duckworth
Ionic liquids have been analyzed in undiluted form using electrospray mass spectrometry (ES-MS); results indicate that signal-to-noise ratios for minor constituents are comparable to those observed in conventional, diluted ES-MS and that this approach could be readily applied for mass spectrometric analysis of ionic liquids and ionic impurities/additives dissolved therein, especially those that are solvent reactive.

18 June 2002 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
DDDouglas Duckworth
Douglas Duckworth
SMShelby J. Morton
Shelby J. Morton
CBCharles K. Bayne
Charles K. Bayne
RKRobert D. Koons
Robert D. Koons
SMShirly Montero
Shirly Montero
JAJose Almirall
Jose Almirall
Glass fragments from 81 automobile side windows were collected and analyzed by the FBI Laboratory using ICP-AES in 1991. The FBI selected 9 elements (Al, Ba, Ca, Fe, Mg, Mn, Na, Sr and Ti) to use for discrimination among the glass samples. This multi-element discrimination showed a significant improvement in the discrimination statistics over using only refractive index (RI) measurements. Oak Ridge National Laboratory (ORNL) recently analyzed fragments from 76 of the original side window fragments using inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS analyses measured 45 elements using a hierarchical sampling scheme to estimate variances due to sampled population (VP), variance due to sample dissolution and within sample heterogeneity (VD), and variance due to replicate measurements (VM). The between-to-within ratio [B/W = VP/(VD + VM)] afforded a measure of the variance within the population to that in the analytical measurement, providing a first approximation of the discriminating power of each element. Florida International University updated the RI measurements on 72 available glass fragments. These RI measurements along with ICP-AES and ICP-MS elemental analyses were used for pairwise comparisons of all possible pairs of the 72 glasses that had a complete set of measurements. The pairwise comparisons used Tukey's HSD method to compare RI and element-by-element discrimination potential of ICP-AES and ICP-MS for analyzing glass in forensic casework.

1 August 2002 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
GJGlen P. Jackson
Glen P. Jackson
FKFred L. King
Fred L. King
DGDouglas E. Goeringer
Douglas E. Goeringer
DDDouglas Duckworth
Douglas Duckworth

1 January 1993 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
DDDouglas Duckworth
Douglas Duckworth
CBChristopher M. Barshick
Christopher M. Barshick
DSDavid H. Smith
David H. Smith
The analysis of soils by conventional solution-based techniques, such as inductively coupled plasma and thermal ionization mass spectrometry, is complicated by the need for sample dissolution or the combination of a solids atomizer with an auxiliary ionization source. Since time is an important consideration in waste remediation, there exists a need for a method of rapidly analysing many soil samples with little sample preparation; glow discharge mass spectrometry (GDMS) has the potential to meet this need. Because GDMS is a bulk solids technique, sample preparation is simplified in comparison to other methods. It appears that, even with the most difficult samples (geological materials, such as soils and volcanic rock), all that is required is grinding, drying and mixing with a conducting host material prior to electrode formation. As a first test of GDMS for soil analysis, a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) was analysed by direct current GDMS. Fifty-one elements were quantified from a single cathode using ion beam ratios and ‘standard’ relative elemental sensitivity factors (RSF). Average errors for the suite of elements were less than a factor of 4 and 1.4 for uncorrected and corrected values, respectively. User-generated RSF values were applied to the analysis of several elements in NIST SRM 2704 Buffalo River Sediment. In the absence of isobaric interferences, accuracies ranging from 0.6 to 73% were observed, demonstrating the potential of the technique for the determination of many elements. The presence of entrained water and inhomogeneity resulting from cathode preparation is thought to affect matrix-to-matrix reproducibility. While further success depends on developing means of circumventing mass spectral interferences and addressing factors affecting plasma chemistry, the immediate goal of developing a screening method for priority metals in soils was met.