Fluorescent sensors benefit from high signal-to-noise and multiple measurement modalities, enabling a multitude of applications and flexibility of design. Semiconductor nanocrystal quantum dots (QDs) are excellent fluorophores for sensors because of their extraordinary optical properties. They have high thermal and photochemical stability compared to organic dyes or fluorescent proteins and are extremely bright due to their large molar cross-sections. In contrast to organic dyes, QD emission profiles are symmetric, with relatively narrow bandwidths. In addition, the size tunability of their emission color, which is a result of quantum confinement, make QDs exceptional emitters with high color purity from the ultra-violet to near infrared wavelength range. The role of QDs in sensors ranges from simple fluorescent tags, as used in immunoassays, to intrinsic sensors that utilize the inherent photophysical response of QDs to fluctuations in temperature, electric field, or ion concentration. In more complex configurations, QDs and biomolecular recognition moieties like antibodies are combined with a third component to modulate the optical signal via energy transfer. QDs can act as donors, acceptors, or both in energy transfer-based sensors using Förster resonance energy transfer (FRET), nanometal surface energy transfer (NSET), or charge or electron transfer. The changes in both spectral response and photoluminescent lifetimes have been successfully harnessed to produce sensitive sensors and multiplexed devices. While technical challenges related to biofunctionalization and the high cost of laboratory-grade fluorimeters have thus far prevented broad implementation of QD-based sensing in clinical or commercial settings, improvements in bioconjugation methods and detection schemes, including using simple consumer devices like cell phone cameras, are lowering the barrier to broad use of more sensitive QD-based devices.
Gene therapy has not yet improved cystic fibrosis (CF) patient lung function in human trials, despite promising preclinical studies. In the human CF lung, inhaled gene vectors must penetrate the viscoelastic secretions coating the airways to reach target cells in the underlying epithelium. We investigated whether CF sputum acts as a barrier to leading adeno-associated virus (AAV) gene vectors, including AAV2, the only serotype tested in CF clinical trials, and AAV1, a leading candidate for future trials. Using multiple particle tracking, we found that sputum strongly impeded diffusion of AAV, regardless of serotype, by adhesive interactions and steric obstruction. Approximately 50% of AAV vectors diffused >1,000-fold more slowly in sputum than in water, with large patient-to-patient variation. We thus tested two strategies to improve AAV diffusion in sputum. We showed that an AAV2 mutant engineered to have reduced heparin binding diffused twice as fast as AAV2 on average, presumably because of reduced adhesion to sputum. We also discovered that the mucolytic N-acetylcysteine could markedly enhance AAV diffusion by altering the sputum microstructure. These studies underscore that sputum is a major barrier to CF gene delivery, and offer strategies for increasing AAV penetration through sputum to improve clinical outcomes.
Solution-phase and intracellular biosensing has substantially enhanced our understanding of molecular processes foundational to biology and pathology. Optical methods are favored because of the low cost of probes and instrumentation. While chromatographic methods are helpful, fluorescent biosensing further increases sensitivity and can be more effective in complex media. Resonance energy transfer (RET)-based sensors have been developed to use fluorescence, bioluminescence, or chemiluminescence (FRET, BRET, or CRET, respectively) as an energy donor, yielding changes in emission spectra, lifetime, or intensity in response to a molecular or environmental change. These methods hold great promise for expanding our understanding of molecular processes not just in solution and in vitro studies, but also in vivo, generating information about complex activities in a natural, organismal setting. In this review, we focus on dyes, fluorescent proteins, and nanoparticles used as energy transfer-based optical transducers in vivo in mice; there are examples of optical sensing using FRET, BRET, and in this mammalian model system. After a description of the energy transfer mechanisms and their contribution to in vivo imaging, we give a short perspective of RET-based in vivo sensors and the importance of imaging in the infrared for reduced tissue autofluorescence and improved sensitivity.
Student engagement is critical to academic success, particularly in the interdisciplinary field of biomedical engineering (BME). However, engaging and motivating students in class have become increasingly challenging, with the COVID-19 pandemic exacerbating this difficulty. This Perspectives paper synthesizes the insights from three faculty workshops focused on identifying and overcoming barriers to classroom engagement, hosted during the 5th BMES Council of Chairs Biomedical Engineering Educational Summit. Key barriers identified during the Summit include student-based challenges—such as student fear of failure, the challenge of connecting course content to real-world applications, and the diversity of student motivations within BME—and instructor-based challenges, such as time constraints and a lack of institutional incentives to prioritize student-centered learning approaches. We present strategies to promote and evaluate student engagement. Finally, we call for a concerted effort in both research and higher institution educational policy to implement evidence-based strategies and faculty training on effective teaching approaches that increase student engagement in the classroom.
The focus on heavy metal-free visible emitters in optoelectronic devices has increased interest in ZnSe semiconductor quantum dots (QDs) over the past decade. Empirical fit equations correlating the lowest energy electron transition to their size and molar extinction coefficients (ε) are often used to determine the concentration of suspensions containing QDs. This is essential to the design and successful synthesis of complex semiconductor nanoparticles including core/shell and dot-in-rod heterostructures as well as consistent device fabrication. While these equations are known and heavily used for CdSe, CdTe, CdS, PbS, etc., they are not well established for ZnSe nanocrystals; the only two reports of ε in the literature differ by over an order of magnitude. In this study, a series of ZnSe QDs with diameters ranging from 2 to 6 nm were characterized with small angle X-ray scattering (SAXS), transmission electron microscopy (TEM), and UV-Vis spectroscopy. SAXS-based size analysis enabled practical inclusion of small particles in the evaluation. Elemental analysis with microwave plasma atomic emission spectroscopy (MP-AES) yields a non-stoichiometric Zn:Se ratio consistent with zinc-terminated spherical ZnSe QDs. Using these combined results, molar extinction coefficients for each QD sample were calculated. Empirical fit equations correlating QD size with its lowest energy electron transition (i.e., 1S peak position) and molar extinction coefficients for both 1S peak and high energy wavelengths are reported. These results will enable the consistent and reliable use of ZnSe core particles in complex heterostructures and devices.