Tina, Ting-Chih Tseng

Prof. Tina, Ting-Chih Tseng


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2014 in Molecules
Verified
Journal Article
Open access
PDF file
TTTina, Ting-Chih Tseng
Tina, Ting-Chih Tseng
CCCheng-Fu Chang
Cheng-Fu Chang
WCWen-Chin Chan
Wen-Chin Chan
Glutamate sensors based on the immobilization of glutamate oxidase (GlutOx) were prepared by adsorption on electrodeposited chitosan (Method 1) and by crosslinking with glutaraldehyde (Method 2) on micromachined platinum microelectrodes. It was observed that glutamate sensors prepared by Method 1 have faster response time (<2 s) and lower detection limit (2.5 ± 1.1 μM) compared to that prepared by Method 2 (response time: <5 sec and detection limit: 6.5 ± 1.7 μM); glutamate sensors prepared by Method 2 have a larger linear detection range (20–352 μM) and higher sensitivity (86.8 ± 8.8 nA·μM−1·cm−2, N = 12) compared to those prepared by Method 1 (linear detection range: 20–217 μM and sensitivity: 34.9 ± 4.8 nA·μM−1·cm−2, N = 8). The applicability of the glutamate sensors in vivo was also demonstrated. The glutamate sensors were implanted into the rat brain to monitor the stress-induced extracellular glutamate release in the hypothalamus of the awake, freely moving rat.

26 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TTTran Nguyen Thanh Thuy
Tran Nguyen Thanh Thuy
TTTina, Ting-Chih Tseng
Tina, Ting-Chih Tseng
In this study, a miniaturized biosensor based on permselective polymer layers (overoxidized polypyrrole (Ppy) and Nafion®) modified and enzyme (glutamate oxidase (GlutOx)) immobilized micro-platinum wire electrode for the detection of alanine aminotransferase (ALT) was fabricated. The proposed ALT biosensor was measured electrochemically by constant potential amperometry at +0.7 V vs. Ag/AgCl. The ALT biosensor provides fast response time (~5 s) and superior selectivity towards ALT against both negatively and positively charged species (e.g., ascorbic acid (AA) and dopamine (DA), respectively). The detection range of the ALT biosensor is found to be 10–900 U/L which covers the range of normal ALT levels presented in the serum and the detection limit and sensitivity are found to be 8.48 U/L and 0.059 nA/(U/L·mm2) (N = 10), respectively. We also found that one-day storage of the ALT biosensor at −20 °C right after the sensor being fabricated can enhance the sensor sensitivity (1.74 times higher than that of the sensor stored at 4 °C). The ALT biosensor is stable after eight weeks of storage at −20 °C. The sensor was tested in spiked ALT samples (ALT activities: 20, 200, 400, and 900 U/L) and reasonable recoveries (70%~107%) were obtained.

23 January 2018 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
LHLe Ngoc Quynh Hoa
Le Ngoc Quynh Hoa
HCHong‐Ru Chen
Hong‐Ru Chen
TTTina, Ting-Chih Tseng
Tina, Ting-Chih Tseng