Ground-based Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements were performed at Tsukuba, Japan (36.1° N, 140.1° E), in November–December 2006. By analyzing the measured spectra of scattered sunlight with DOAS and optimal estimation methods, we first retrieve the aerosol optical depth (τ) and the vertical profile of the aerosol extinction coefficient (k) at 476 nm in the lower troposphere. These retrieved quantities are characterized through comparisons with coincident lidar and sky radiometer measurements. The retrieved k values for layers of 0–1 and 1–2 km agree with lidar data to within 30% and 60%, respectively, for most cases, including partly cloudy conditions. Results similar to k at 0–1 km are obtained for the retrieved τ values, demonstrating that MAX-DOAS provides a new, unique aerosol dataset in the lower troposphere.
1 September 2006 in Journal of the Atmospheric Sciences
Demands for Monte Carlo radiative transfer modeling have grown with the increase in computational power in recent decades. This method provides realistic simulations of radiation processes for various types of application, including radiation budgets in cloudy conditions and remote measurements of clouds, aerosols, and gases. Despite many advantages, such as explicit treatment of three-dimensional radiative transfer, issues of numerical efficiency can make the method intractable, especially in radiance calculations. The commonly used local estimation method requires computationally intensive ray tracing at each collision. Furthermore, the realistic phase function of Mie scattering by cloud and aerosol particles has very sharp peaks in the forward direction. Radiance computations by Monte Carlo methods are inefficient for such spiky phase functions because of significant noise. Moreover, in optically thin regions, sampling of radiance contributions is so rare that long computing times are required to reduce noise. To solve these issues, several variance reduction methods have been proposed. This paper discusses a modified local estimation method, a truncation approximation for a highly anisotropic phase function, a collision-forcing method for optically thin media, a numerical diffusion technique, and several related topics. Numerical experiments demonstrated significant improvements in efficiency for solar radiance calculations in a limited number of cloudy cases.
We conducted long-term network observations using standardized Multi-Axis Differential optical absorption spectroscopy (MAX-DOAS) instruments in Russia and ASia (MADRAS) from 2007 onwards and made the first synthetic data analysis. At seven locations (Cape Hedo, Fukue and Yokosuka in Japan, Hefei in China, Gwangju in Korea, and Tomsk and Zvenigorod in Russia) with different levels of pollution, we obtained 80 927 retrievals of tropospheric NO2 vertical column density (TropoNO2VCD) and aerosol optical depth (AOD). In the technique, the optimal estimation of the TropoNO2VCD and its profile was performed using aerosol information derived from O4 absorbances simultaneously observed at 460–490 nm. This large data set was used to analyze NO2 climatology systematically, including temporal variations from the seasonal to the diurnal scale. The results were compared with Ozone Monitoring Instrument (OMI) satellite observations and global model simulations. Two NO2 retrievals of OMI satellite data (NASA ver. 2.1 and Dutch OMI NO2 (DOMINO) ver. 2.0) generally showed close correlations with those derived from MAX-DOAS observations, but had low biases of up to ~50%. The bias was distinct when NO2 was abundantly present near the surface and when the AOD was high, suggesting a possibility of incomplete accounting of NO2 near the surface under relatively high aerosol conditions for the satellite observations. Except for constant biases, the satellite observations showed nearly perfect seasonal agreement with MAX-DOAS observations, suggesting that the analysis of seasonal features of the satellite data were robust. Weekend reduction in the TropoNO2VCD found at Yokosuka and Gwangju was absent at Hefei, implying that the major sources had different weekly variation patterns. While the TropoNO2VCD generally decreased during the midday hours, it increased exceptionally at urban/suburban locations (Yokosuka, Gwangju, and Hefei) during winter. A global chemical transport model, MIROC-ESM-CHEM (Model for Interdisciplinary Research on Climate–Earth System Model–Chemistry), was validated for the first time with respect to background NO2 column densities during summer at Cape Hedo and Fukue in the clean marine atmosphere.
1 January 2018 in Journal of the Meteorological Society of Japan
An algorithm for retrieving the macroscopic, physical, and optical properties of clouds from thermal infrared measurements is applied to the Himawari-8 multiband observations. A sensitivity study demonstrates that the addition of the single CO2 band of Himawari-8 is effective for the estimation of cloud top height. For validation, retrieved cloud properties are compared systematically with collocated active remote sensing counterparts with small time lags. While retrievals agree reasonably for single-layer clouds, multilayer cloud systems with optically thin upper clouds overlying lower clouds are the major source of error in the present algorithm. Validation of cloud products is critical for identifying the characteristics, advantages, and limitation of each product and should be continued in the future. As an application example, data are analyzed for eight days in the vicinity of the New Guinea to study the diurnal cycle of the cloud system. The present cloud property analysis investigates cloud evolution through separation of different cloud types and reveals typical features of diurnal cycles related to the topography. Over land, middle clouds increase from 0900 to 1200 local solar time (LST), deep convective clouds develop rapidly during 1200-1700 LST with a subsequent increase in cirrus and cirrostratus cloud amounts. Over the ocean near coastlines, a broad peak of convective cloud fraction is seen in the early morning. The present study demonstrates the utility of frequent observations by Himawari-8 for life cycle study of cloud systems, owing to the ability to capture their continuous temporal variations.
21 October 2016 in Progress in Earth and Planetary Science
Satellite remote sensing of the macroscopic, microphysical, and optical properties of clouds are useful for studying spatial and temporal variations of clouds at various scales and constraining cloud physical processes in climate and weather prediction models. Instead of using separate independent algorithms for different cloud properties, a unified, optimal estimation-based cloud retrieval algorithm is developed and applied to moderate resolution imaging spectroradiometer (MODIS) observations using ten thermal infrared bands. The model considers sensor configurations, background surface and atmospheric profile, and microphysical and optical models of ice and liquid cloud particles and radiative transfer in a plane-parallel, multilayered atmosphere. Measurement and model errors are thoroughly quantified from direct comparisons of clear-sky observations over the ocean with model calculations. Performance tests by retrieval simulations show that ice cloud properties are retrieved with high accuracy when cloud optical thickness (COT) is between 0.1 and 10. Cloud-top pressure is inferred with uncertainty lower than 10 % when COT is larger than 0.3. Applying the method to a tropical cloud system and comparing the results with the MODIS Collection 6 cloud product shows good agreement for ice cloud optical thickness when COT is less than about 5. Cloud-top height agrees well with estimates obtained by the CO2 slicing method used in the MODIS product. The present algorithm can detect optically thin parts at the edges of high clouds well in comparison with the MODIS product, in which these parts are recognized as low clouds by the infrared window method. The cloud thermodynamic phase in the present algorithm is constrained by cloud-top temperature, which tends not to produce results with an ice cloud that is too warm and liquid cloud that is too cold.