Hongxiang Kang

Prof. Dr. Hongxiang Kang


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Laser Physics Letters
Verified
Journal Article
Closed access
PDF file
HKHongxiang Kang
Hongxiang Kang
HZH. Zhang
H. Zhang
PYP. Yan
P. Yan
DWD.S. Wang
D.S. Wang
MGM. Gong
M. Gong

15 November 2013 in Laser Physics Letters
Verified
Journal Article
Closed access
BSB J Shen
B J Shen
HKHongxiang Kang
Hongxiang Kang
DSD L Sun
D L Sun
QZQ L Zhang
Q L Zhang
SYSHUAI YIN
SHUAI YIN
JLJ Liang
J Liang

12 November 2015 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
BSBenjian Shen
Benjian Shen
HKHongxiang Kang
Hongxiang Kang
PCPeng Chen
Peng Chen
JLJie Liang
Jie Liang
QMQiong Ma
Qiong Ma
LGLiucun Gao
Liucun Gao

19 June 2020 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
YFYingwei Fan
Yingwei Fan
QMQiong Ma
Qiong Ma
SXShenghai Xin
Shenghai Xin
RPRuiyun Peng
Ruiyun Peng
HKHongxiang Kang
Hongxiang Kang

13 November 2020 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
QMQiong Ma
Qiong Ma
YFYingwei Fan
Yingwei Fan
ZLZhenkun Luo
Zhenkun Luo
YCYufang Cui
Yufang Cui
HKHongxiang Kang
Hongxiang Kang

9 July 2019 in IEEE Access
Verified
Journal Article
Open access
YFYingwei Fan
Yingwei Fan
SLSite Luo
Site Luo
HKHongxiang Kang
Hongxiang Kang
The standard technical scheme for imaging with an endoscopic optical coherence tomography (OCT) probe is to use a GRIN lens to focus the beam. However, when a long working distance is required of the OCT probe, various factors will affect the imaging quality. Here, we conduct a theoretical calculation to analyze the sensitivity of the GRIN lens and the C-lens of an OCT probe. The sensitivity of ω0 Vs L of the GRIN lens is ten times higher than that of the C-lens. The sensitivity of Z0Vs L of the GRIN lens is 24 times higher than that of the C-lens. Additionally, the sensitivity of the radius of curvature of the C-lens is compared with the sensitivity of the length of the GRIN lens, and the sensitivity for the GRIN lens is about five times higher than the sensitivity of the radius of curvature for the C-lens. Furthermore, fabricating a C-lens-based OCT probe is much cheaper than a GRIN-lens-based one. Hence, our calculations suggest that the C-lens is a better choice for a long-working-distance OCT probe.