Cloud droplets size distribution (DSD) is one of the significant characteristics for liquid clouds. It plays an important role for the aerosol–droplet–cloud mechanism and variation in cloud microphysics. However, the minuscule sampling space is insufficient for the observation of whole DSD when using high-magnification optical systems. In this paper, we propose an observation method for cloud droplets ranging from 2 to 16 μm, by which the balance relationship between sampling space and optical magnification is realized. The method combines an in-line digital holographic interferometer (DHI) with the optical magnification of 5.89× and spatial stitching technique. The minimum size in DSD is extended to 2 μm, which improves the integrity of size distribution. Simultaneously, the stability of DSD is enhanced by increasing the tenfold sampling volume of cloud droplets. The comparative experiment between the in-line DHI and fog monitor demonstrates that the DSD obtained by this method is reliable, which can be used for the analysis of microphysical parameters. In the Beijing Aerosol and Cloud Interaction Chamber (BACIC), the observation results show that the size of cloud droplets follows the Gamma distribution, which is consistent with the theoretical DSD. The results of cloud microphysical parameters indicate that each pair of parameters has a positive correlation, and then the validity of observation method is confirmed. Additionally, the high-concentration aerosol condition significantly mitigates the effect of random turbulence and enhances the robustness of the microphysical parameter data.
The velocity of cloud droplets has a significant effect on the investigation of the turbulence-cloud microphysics interaction mechanism. The paper proposes an in-line digital holographic interferometry (DHI) technique based on depth expansion and self-fusion algorithm to simultaneously extract particle velocity from eight holograms. In comparison to the two-frame exposure method, the extraction efficiency of velocity is raised by threefold, and the number of reference particles used for particle registration is increased to eight. The experimental results obtained in the cloud chamber show that the velocity of cloud droplets increases fourfold from the stabilization phase to the dissipation phase. The measurement deviations of two phases are 1.138 and 1.153 mm/s, respectively. Additionally, this method provides a rapid solution for three-dimensional particle velocimetry investigation of turbulent field stacking and cloud droplets collisions.
The sky-radiometer/sun-photometer is the most widely used instrument for obtaining aerosol optical depth (AOD) or aerosol optical properties worldwide. Due to the existence of field of view (FOV, 1°), the radiation received by the sky-radiometer includes the forward scattering in addition to direct solar irradiance. This leads to more diffuse light errors of retrieved AODs, especially for shorter wavelength and heavily polluted weather conditions. Using simulation data of three typical aerosol particles (dust, soot, water-soluble), we first verified the accuracy of the Monte Carlo method for calculating the forward scattering effect. Based on the sky-radiometer data collected in Xi’an (2015–2020) where heavy pollution weather is common, the relative errors and correction factors of the AOD were obtained under different conditions, including various short wavelengths (≤400 nm), solar zenith angles (SZAs) and AODs. Our analysis indicates the close dependence of AOD correction factors on wavelength, SZA, AOD and the optical properties of aerosol particles. The mean relative error in Xi’an increases with the decrease of wavelength (~16.1% at 315 nm) and decreases first and then increases with the increase of the SZA. The relative errors caused by forward scattering can exceed 10% when the AOD is greater than 1 and 25% when the AOD is larger than 2 in the ultraviolet (UV) band. The errors with a wavelength greater than 400 nm and an AOD below 1.0 can be within 5%, which can be ignored. The correlation coefficients of AODs before and after a correction from 315 nm to 400 nm are greater than 0.96, which basically increase with the increase of the wavelength. This indicates that the significance of the forward scattering effect in the Xi’an area with heavy pollution cannot be ignored for short wavelengths. However, such effect is negligible at the longer wavelengths and lower AODs (<1.0) of a sky-radiometer.
The identification of raindrops and hailstones is of great significance to the study of precipitation characteristics from the aspect of microphysics and can provide important data support for weather modification. In this paper, an identification method of raindrops and hailstones based on digital holographic interference is proposed. The grayscale gradient variance method is used to obtain the focus position of the particles. By means of binarization and morphological processing, digital holograms are processed to obtain clear profiles of the particles. Then the contour parameters of the particles are used to obtain the equivalent volume diameter and roundness. Finally, according to the equivalent volume diameter, roundness and lens-like effect of the particles, the phase states of the raindrop and hailstone are identified by the algorithm. Experiments show that the method proposed in this paper has a good identification effect on raindrops and hailstones. The research results can provide reference for the research of the identification method of raindrops and hailstones and the acquisition of accurate characteristic parameters.
The measurement of cloud microphysical parameters plays an important role in describing characteristics of liquid phase clouds and investigating mutual relationships between clouds and precipitation. In this paper, cloud microphysical parameters at Liupan Mountain Weather Station in Ningxia are measured with a high-resolution coaxial digital holographic imager and a fog monitor 120. There are differences in the measurement results between the two instruments. The number concentration measured by the digital holographic imager is about 1.5 times that of the fog monitor 120. However, their Pearson correlation coefficient is above 0.9. Through analysis, we found that the measurement results of the digital holographic imager and fog monitor 120 are differences in 2–4 µm and 7–50µm. For the droplets with the diameters of 4–7 µm, their measurement results have good consistency. By analyzing the influence of wind field and detection sensitivity on the measurement principle, the reasons which caused the difference are proposed. Advice is given to observe topographic clouds by using the above two instruments. In addition, the differences in liquid water content and visibility are analyzed due to the absence of small and large droplets. The study provides data support for improving the accuracy of instruments in measuring cloud droplets and is useful for research in the field of cloud microphysical processes.