Yusuke Tsuboko

Dr. Yusuke Tsuboko

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2011 in Journal of Artificial Organs
Verified
Journal Article
Closed access
ISIchiro Suzuki
Ichiro Suzuki
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
SYShota Yabe
Shota Yabe
YTYusuke Tsuboko
Yusuke Tsuboko
TSTelma Keiko Sugai
Telma Keiko Sugai
TYTomoyuki Yambe
Tomoyuki Yambe

14 July 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
JTJumpei Takada
Jumpei Takada
KHKohei Hamada
Kohei Hamada
XZXiaodong Zhu
Xiaodong Zhu
YTYusuke Tsuboko
Yusuke Tsuboko
KIKiyotaka Iwasaki
Kiyotaka Iwasaki

20 November 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
YTYusuke Tsuboko
Yusuke Tsuboko
HSHideyuki Sakoda
Hideyuki Sakoda
YOYoshihiro Okamoto
Yoshihiro Okamoto
YNYusuke Nomura
Yusuke Nomura
EYEiichi Yamamoto
Eiichi Yamamoto
Background: This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). Methods: Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load–displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. Results: The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. Conclusions: Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.

18 April 2015 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
AYAkihiro Yamada
Akihiro Yamada
YSYasuyuki Shiraishi
Yasuyuki Shiraishi
HMHidekazu Miura
Hidekazu Miura
HHHashem Mohamed Omran Hashem
Hashem Mohamed Omran Hashem
YTYusuke Tsuboko
Yusuke Tsuboko
TYTomoyuki Yambe
Tomoyuki Yambe

1 July 2013 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
AYA. Yamada
A. Yamada
YSY. Shiraishi
Y. Shiraishi
HMH. Miura
H. Miura
TYT. Yambe
T. Yambe
MOM. H. Omran
M. H. Omran
MYM. Yamagishi
M. Yamagishi
Fontan procedure is one of the common surgical treatments of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. We have been developing a pulmonary circulatory assist device using shape memory alloy fibers for Fontan circulation with total cavopulmonary connection. It consisted of the shape memory alloy fibers, the diameter of which are 100 μm. The fibers could wrap the ePTFE conduit for Fontan TCPC connection from the outside. We designed the sequential motion control system for sophisticated pulmonary hemodynamics by the pulsatile flow generation. In order to achieve pulsatile flow assistance in pulmonary arterial system, we fabricated a mechanical structure by sequential contraction of shape memory alloy fibers. Then, we developed a sequential contraction controller for the assist system, which could reproduce the wall contractile velocity at 6.0 to 20.0 cm/sec. We examined hemodynamic characteristic of its function using a mock circulatory system, which consisted of two overflow tanks representing venous and pulmonary arterial pressures in Fontan circulation. As a result, the pulmonary circulation assist device with sequential contraction could achieve effective promotion of the pulsatility in pulmonary arterial flow.

1 July 2013
Verified
Conference Paper
Closed access
MHMohamed O. Hashem
Mohamed O. Hashem
AYA. Yamada
A. Yamada
YTYusuke Tsuboko
Yusuke Tsuboko
HMH. Muira
H. Muira
DHD. Homma
D. Homma
TYT. Yambe
T. Yambe
Diastolic counter-pulsation has been used to provide circulatory augmentation for short term cardiac support. The success of intra-aortic balloon pump (IABP) therapy has generated interest in long term counter-pulsation strategies to treat heart failure patients. The authors have been developing a totally implantable extra aortic pulsation device for the circulatory support of heart failure patients, using 150μm Ni-Ti anisotropic shape memory alloy (SMA) fibers. These fibers contract by Joule heating with an electric current supply. The special features of our design are as follow: non blood contacting, extra aortic pulsation function synchronizing with the native heart, a wrapping mechanical structure for the aorta in order to achieve its assistance as the aortomyoplsty and the extra aortic balloon pump. The device consisted of rubber silicone wall plates, serially connected for radial contraction. We examined the contractile function of the device, as well as it controlling methods; the phase delay parameter and the pulse width modulation, in a systemic mock circulatory system, with a pneumatically driven silicone left ventricle model, arterial rubber tubing, a peripheral resistance unit, and a venous reservoir. The device was secured around the aortic tubing with a counter-pulsation mode of 1-4 against the heartbeat. Pressure and flow waveforms were measured at the aortic outflow, as well as its driving condition of the contraction phase width and the phase delay. The device achieved its variable phase control for co-pulsation or counter-pulsation modes by changing the phase delay of the SMA fibers. Peak diastolic pressure significantly augmented, mean flow increased (p<;0.05) according to the pulse width modulation. Therefore the newly developed extra aortic counter-pulsation device using SMA fibers, through it controlling methods indicated its promising alternative extra aortic approach for non-blood contacting cardiovascular circulatory support.