Austin Downey

Dr. Austin Downey

Department of Mechanical Engineering, University of South Carolina, Columbia, Connecticut, USA
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in Journal of Manufacturing Processes
Verified
Journal Article
Closed access
YFYanzhou Fu
Yanzhou Fu
Austin DowneyAustin Downey
Austin Downey
LYLang Yuan
Lang Yuan
TZTianyu Zhang
Tianyu Zhang
APAvery Pratt
Avery Pratt
YBYunusa Balogun
Yunusa Balogun

1 February 2019 in Reliability Engineering & System Safety
Verified
Journal Article
Closed access
Austin DowneyAustin Downey
Austin Downey
YLYu-Hui Lui
Yu-Hui Lui
CHChao Hu
Chao Hu
Simon LaflammeSimon Laflamme
Simon Laflamme
SHShan Hu
Shan Hu

1 February 2021 in Journal of Power Sources
Verified
Journal Article
Closed access
YLYu Hui Lui
Yu Hui Lui
MLMeng Li
Meng Li
Austin DowneyAustin Downey
Austin Downey
SSSheng Shen
Sheng Shen
VNVenkat Pavan Nemani
Venkat Pavan Nemani
CHChao Hu
Chao Hu

2 May 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
Austin DowneyAustin Downey
Austin Downey
Antonella D'AlessandroAntonella D'Alessandro
Antonella D'Alessandro
Filippo UbertiniFilippo Ubertini
Filippo Ubertini
Simon LaflammeSimon Laflamme
Simon Laflamme
RGRandall Geiger
Randall Geiger
Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real-time utilization of self-sensing materials in structural health monitoring.

9 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea MeoniAndrea Meoni
Andrea Meoni
Antonella D'AlessandroAntonella D'Alessandro
Antonella D'Alessandro
Austin DowneyAustin Downey
Austin Downey
EGEnrique García-Macías
Enrique García-Macías
MRMarco Rallini
Marco Rallini
Filippo UbertiniFilippo Ubertini
Filippo Ubertini
The availability of new self-sensing cement-based strain sensors allows the development of dense sensor networks for Structural Health Monitoring (SHM) of reinforced concrete structures. These sensors are fabricated by doping cement-matrix mterials with conductive fillers, such as Multi Walled Carbon Nanotubes (MWCNTs), and can be embedded into structural elements made of reinforced concrete prior to casting. The strain sensing principle is based on the multifunctional composites outputting a measurable change in their electrical properties when subjected to a deformation. Previous work by the authors was devoted to material fabrication, modeling and applications in SHM. In this paper, we investigate the behavior of several sensors fabricated with and without aggregates and with different MWCNT contents. The strain sensitivity of the sensors, in terms of fractional change in electrical resistivity for unit strain, as well as their linearity are investigated through experimental testing under both quasi-static and sine-sweep dynamic uni-axial compressive loadings. Moreover, the responses of the sensors when subjected to destructive compressive tests are evaluated. Overall, the presented results contribute to improving the scientific knowledge on the behavior of smart concrete sensors and to furthering their understanding for SHM applications.

18 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JYJIN YAN
JIN YAN
Austin DowneyAustin Downey
Austin Downey
ACAlessandro Cancelli
Alessandro Cancelli
Simon LaflammeSimon Laflamme
Simon Laflamme
ACAn Chen
An Chen
Filippo UbertiniFilippo Ubertini
Filippo Ubertini
Cracks in concrete structures can be indicators of important damage and may significantly affect durability. Their timely identification can be used to ensure structural safety and guide on-time maintenance operations. Structural health monitoring solutions, such as strain gauges and fiber optics systems, have been proposed for the automatic monitoring of such cracks. However, these solutions become economically difficult to deploy when the surface under investigation is very large. This paper proposes to leverage a novel sensing skin for monitoring cracks in concrete structures. This sensing skin is constituted of a flexible electronic termed soft elastomeric capacitor, which detects a change in strain through changes in measured capacitance. The SEC is a low-cost, durable, and robust sensing technology that has previously been studied for the monitoring of fatigue cracks in steel components. In this study, the sensing skin is introduced and preliminary validation results on a small-scale reinforced concrete beam are presented. The technology is verified on a full-scale post-tensioned concrete beam. Results show that the sensing skin is capable of detecting, localizing, and quantifying cracks that formed in both the reinforced and post-tensioned concrete specimens.