A new self-mixing interferometry based on sinusoidal phase modulating technique is presented. Self-mixing interference occurs in the laser cavity by reflecting the light from a mirror-like target in front of the laser. Sinusoidal phase modulation of the beam is obtained by an electro-optic modulator (EOM) in the external cavity. The phase of the interference signal is calculated by Fourier analysis method. The interferometer is applied to measure the displacement of a high-precision commercial PZT with an accuracy of <10nm. The measurement range of the system mainly depends on the maximum operating frequency of EOM and the maximum sampling rate of A/D converter.
A new, to the best of our knowledge, method for the measurement of the absolute distance of a remote target based on the laser diode self-mixing interferometry is presented. A double-modulation technique is introduced to improve the measurement resolution. Wavelength modulation of the laser beam is obtained by modulating the injection current of the laser diode. Phase modulation of the laser beam is obtained by an electro-optic crystal in the external cavity. Absolute distance of the external target is determined by the Fourier analysis method. Theoretical analysis and numerical simulations are given. Experimental results show that a resolution of can be achieved for absolute distance ranging from 277 to .
A new approach for self-mixing interference in fiber ring laser and its application to vibration measurement is presented. Fourier transform method is proposed to improve the measurement accuracy of such an active sensing, in which the basic frequency of self-mixing interference signal is used to determine the frequency of vibration, and the stop order of the harmonic components is proportional to the amplitude of vibration. We have demonstrated this system to measure the microscopic vibration of a remote target. Some errors due to this method are discussed. The maximum error of the amplitude is about λ/10 and the maximum error of the frequency is about 10%, showing a good agreement with the simulative results.
A self-mixing birefringent dual-frequency laser Doppler velocimeter (SBD-LDV) for high-resolution velocity measurements is presented in this paper. The velocity information of the object can be accurately extracted from the self-mixing Doppler frequency shift of the birefringent light-carried microwave signal. We generate a virtual stable light-carried microwave by using a birefringent dual-frequency He-Ne laser which further simplifies the structure of the light source. Moreover, the optical configuration based on the laser self-mixing interference brings benefits of compact optical setup, self-alignment, and direction discriminability. Experimentally, we extracted the Doppler beat frequency signal by the low-frequency (millihertz) phase lock-in amplifier, measured the beat frequency precisely in time-domain with a low sampling rate and calculated the magnitude of velocity. Compared with the previous self-mixing LDV, the average velocity resolution of SBD-LDV is improved to 0.030 mm/s for a target with longitudinal velocity, benefiting from the high stability of light-carried microwave. It is of great meaning and necessity because it helps to provide an available velocimeter with high stability and an extremely compact configuration, making a potential contribution to the velocimetry in practical engineering application.
A novel sapphire fiber-optic high-temperature sensor has been designed and fabricated based on blackbody radiation theory. Metallic molybdenum has been used as the film material to develop the blackbody cavity, owing to its relatively high melting point compared to that of sapphire. More importantly, the fabrication process for the blackbody cavity is simple, efficient, and economical. Thermal radiation emitted from such a blackbody cavity is transmitted via optical fiber to a remote place for detection. The operating principle, the sensor structure, and the fabrication process are described here in detail. The developed high-temperature sensor was calibrated through a calibration blackbody furnace at temperatures from 900°C to 1200°C and tested by a sapphire crystal growth furnace up to 1880°C. The experimental results of our system agree well with those from a commercial Rayteck MR1SCCF infrared pyrometer, and the maximum residual is approximately 5°C, paving the way for high-accuracy temperature measurement especially for extremely harsh environments.
An optical MEMS pressure sensor based on a mesa-diaphragm is presented. The operating principle of the sensor is expatiated by Fabry-Perot (F-P) interference. Both the mechanical model and the signal averaging effect of the mesa diaphragm is validated by simulation, which declares that the mesa diaphragm is superior to the planar one on the parallelism and can reduce the signal averaging effect. Experimental results demonstrate that the mesa structure sensor has a reasonable linearity and sensitivity.