Zhengtao Ai

Prof. Zhengtao Ai

National Center for International Research Collaboration in Building Safety and Environment, College of Civil Engineering, Hunan University, Changsha 410082, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2020 in Building Simulation
Verified
Journal Article
Open access
PDF file
Zhengtao AiZhengtao Ai
Zhengtao Ai
Cheuk Ming MakCheuk Ming Mak
Cheuk Ming Mak
NGNaiping Gao
Naiping Gao
JNJianlei Niu
Jianlei Niu

1 November 2021 in Energy and Buildings
Verified
Journal Article
Open access
CZChen Zhang
Chen Zhang
OKOngun Berk Kazanci
Ongun Berk Kazanci
RLRonnen Levinson
Ronnen Levinson
PHPer Heiselberg
Per Heiselberg
BOBjarne W. Olesen
Bjarne W. Olesen
GZGuoqiang Zhang
Guoqiang Zhang

1 October 2017 in Building and Environment
Verified
Journal Article
Open access
YDYaxing Du
Yaxing Du
Cheuk Ming MakCheuk Ming Mak
Cheuk Ming Mak
KKKenny Kwok
Kenny Kwok
KTKam-Tim Tse
Kam-Tim Tse
TLTsz-Cheung Lee
Tsz-Cheung Lee
JNJianlei Niu
Jianlei Niu
The choice of proper wind comfort criterion is considered to be crucial to reliable assessment of pedestrian level wind comfort. This paper aims to propose a wind comfort criterion that can be applied to Hong Kong, in which the wind comfort is seriously deteriorated by the moderated airflow, particularly in the hot and humid summer. By thoroughly reviewing and comparing exiting wind comfort criteria, the parameters in Lawson (1978) criterion are adopted for acceptable, tolerable and intolerable category and the parameters in NEN8100 (2006) criterion are adopted for danger category in the proposed criteria. Besides, a low wind parameter suggested by AVA scheme (2005) is adopted for unfavourable category in summer criterion. The adopted parameters provide scientific foundations and they are carefully chosen to adapt the weak wind conditions. The prominent features of the criteria are proposed seasonally (summer and winter, respectively) and the overall mean wind velocity ratio (OMVR) is used as threshold wind velocity parameter. The wind tunnel tests of Hong Kong Polytechnic University (HKPolyU) campus model were used as a case study. The results show that the proposed criteria can reasonably represent the weak wind condition and provide suitable assessments of the wind comfort in Hong Kong. Moreover, the findings in this study provide scientific basis for future policy-making and the proposed criteria can also help city planners to improve the pedestrian level wind comfort.Department of Building Services Engineering2016-2017 > Academic research: refereed > Publication in refereed journalbcr

1 January 2019 in Building and Environment
Verified
Journal Article
Closed access
Sheng ZhangSheng Zhang
Sheng Zhang
John Zhang LinJohn Zhang Lin
John Zhang Lin
Zhengtao AiZhengtao Ai
Zhengtao Ai
FWFenghao Wang
Fenghao Wang
YCYong Cheng
Yong Cheng
CHChao Huan
Chao Huan

1 June 2018 in Building and Environment
Verified
Journal Article
Closed access
YDYuwei Dai
Yuwei Dai
Cheuk Ming MakCheuk Ming Mak
Cheuk Ming Mak
Zhengtao AiZhengtao Ai
Zhengtao Ai
Jian HangJian Hang
Jian Hang

1 August 2021 in Building and Environment
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
XDXiahong Dai
Xiahong Dai
JWJianjian Wei
Jianjian Wei
Zhengtao AiZhengtao Ai
Zhengtao Ai
YFYifan Fan
Yifan Fan
JGJian Ge
Jian Ge