Mingming Wei

Dr. Mingming Wei


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2019 in MAPAN
Verified
Journal Article
Closed access
PDF file
MWMingming Wei
Mingming Wei
YZYang Zeng
Yang Zeng
CWChunhua Wen
Chunhua Wen
XLXiaogang Liu
Xiaogang Liu
CLChangchun Li
Changchun Li
SXShan Xu
Shan Xu

13 September 2019 in MAPAN
Verified
Journal Article
Closed access
PDF file
MWMingming Wei
Mingming Wei
YZYang Zeng
Yang Zeng
LZLi Zou
Li Zou
CWChunhua Wen
Chunhua Wen
XLXiaogang Liu
Xiaogang Liu
SXShan Xu
Shan Xu

29 April 2024 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
MWMingming Wei
Mingming Wei
XLXin Liu
Xin Liu
LZLi Zou
Li Zou
TZTaocheng Zhou
Taocheng Zhou
DZDebin Zheng
Debin Zheng

1 March 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MWMingming Wei
Mingming Wei
YQYan Qi
Yan Qi
XCXingwang Chen
Xingwang Chen
TZTaocheng Zhou
Taocheng Zhou
JMJie Miao
Jie Miao
To further improve the accuracy of the measurement uncertainty evaluation results of the aneroid barometer and verify the applicability of the GUM evaluation of the aneroid barometer, the Monte Carlo method (MCM) is proposed to evaluate the measurement uncertainty of the calibration results of the aneroid barometer. An improved calibration technique for the aneroid barometer was utilized in this process, yielding more precise calibration data through a meticulously designed experimental program. Subsequently, single-batch MCM and adaptive MCM (AMCM) were applied separately for evaluation, and their results were compared and analyzed against the GUM method to verify the applicability of each approach. In addition, to comprehensively assess the effectiveness of the new methods, this study also conducted control evaluations using traditional methods that did not account for the effects of the coefficient box and indicator box performance. The results show that MCM is superior to the GUM method in accuracy and reliability and is also more efficient in execution. In particular, the evaluation results of single-batch MCM and AMCM are in good agreement, but AMCM shows a superior performance with fewer simulations and more efficient execution. When evaluating the uncertainty of the temperature coefficient, introducing the new method has little effect on the evaluation results; however, when evaluating the uncertainty of the indication error, introducing a new method can significantly improve the accuracy of the evaluation results. This indicates that the new method has significant advantages in improving the accuracy of the evaluation results. In addition, the GUM method was validated by MCM, and the results showed that the GUM method is still suitable for the measurement uncertainty evaluation of the indication error of the aneroid barometer. Therefore, it is recommended that MCM, especially AMCM, which is more efficient in implementation, should be preferred in the field of measurement uncertainty evaluation of the aneroid barometer; meanwhile, the GUM method, as the basic assessment method in this field, should be retained and continue to play its role.

1 March 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MWMingming Wei
Mingming Wei
CWChunhua Wen
Chunhua Wen
YCYinbao Cheng
Yinbao Cheng
SYShun Yao
Shun Yao
LHLing Hong
Ling Hong
TZTaocheng Zhou
Taocheng Zhou
Addressing the oversight in the evaluation of measurement uncertainty for traditional aneroid barometers, where the performance of calibration equipment (in particular, the temperature coefficient calibration box, henceforth termed the coefficient box, and the indication calibration box, referred to as the indication box) and the uncertainty associated with the temperature coefficient are frequently neglected, this paper introduces an enhanced evaluation framework. The objective of this framework is to achieve a more precise evaluation of measurement uncertainty and to enhance the accuracy of calibration outcomes. Initially, a comprehensive calibration methodology is devised, accounting for the impact of the coefficient box’s performance on the temperature coefficient and the influence of the indication box’s performance on the indication error. By executing this methodology, detailed empirical test data are procured. Subsequently, incorporating various factors that affect the measurement outcomes, the measurement uncertainty is evaluated utilizing the collected data. The evaluation results reveal that the uncertainty of the temperature coefficient is U = 0.004 hPa/°C (k = 2), and the uncertainty of the indication error is U = 0.12 hPa (k = 2). For comparison, the traditional calibration approach yields an uncertainty of the temperature coefficient of U = 0.004 hPa/°C (k = 2) and an uncertainty of the indication error of U = 0.09 hPa (k = 2). Through a comparative analysis, it is evident that the coefficient box’s performance has little effect on the temperature coefficient’s uncertainty; however, neglecting the performance of the indication box and the temperature coefficient’s uncertainty can result in the evaluation of the indication error’s uncertainty deviating from actuality. Consequently, it is recommended that the effects of the indication box’s performance and the temperature coefficient’s uncertainty be thoroughly considered when evaluating the measurement uncertainty of an aneroid barometer’s indication error. By doing so, more authentic and reliable evaluation results can be obtained, ultimately enhancing the accuracy of the aneroid barometer’s calibration outcomes.

25 March 2024 in MAPAN
Verified
Journal Article
Closed access
PDF file
MWMingming Wei
Mingming Wei
CWChunhua Wen
Chunhua Wen
CLChangchun Li
Changchun Li
JMJie Miao
Jie Miao