In the present work, an improved model of the Raman gas analyzer (RGA) of natural gas (NG) developed by us is described together with its operating principle. The sensitivity has been improved and the number of measurable gases has been expanded. Results of its approbation on a real NG sample are presented for different measurement times. A comparison of the data obtained with the results of chromatographic analysis demonstrates their good agreement. The time stability of the results obtained using this model is analyzed. It is experimentally established that the given RGA can reliably determine the content of all molecular NG components whose content exceeds 0.005% for 100 s; moreover, in this case the limiting sensitivity for some NG components is equal to 0.002%.
In the present work, a multipass optical system intended for increasing the sensitivity of a Raman gas spectrometer based on the 90° geometry of scattered light collection is described. The system is characterized by an adjustment stability and an increased number of laser beams that pass through a small scattering volume, thus allowing the intensities of Raman signals from components of the gas medium in this volume to be increased. It is demonstrated that the application of this multipass optical system allows the sensitivity of the Raman gas spectrometer to be increased practically by 20 times (to several ppm for the 30-s registration time).
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Raman spectroscopy is a promising method for analyzing natural gas due to its high measurement speed and the potential to monitor all molecular components simultaneously. This paper discusses the features of measurements of samples whose composition varies over a wide range (0.005–100%). Analysis of the concentrations obtained during three weeks of experiments showed that their variation is within the error caused by spectral noise. This result confirms that Raman gas analyzers can operate without frequent calibrations, unlike gas chromatographs. It was found that a variation in the gas composition can change the widths of the spectral lines of methane. As a result, the measurement error of oxygen concentration can reach 200 ppm. It is also shown that neglecting the measurement of pentanes and n-hexane leads to an increase in the calculated concentrations of other alkanes and to errors in the density and heating value of natural gas.
1 February 2018 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy