Utilizing thermal storage integrated into a solar air heater SAH is a promising solution to enhance the thermal performance of solar air heaters. The present work experimentally investigated the thermal impact of an absorber-finned heat exchanger-thermal storage unit integrated inside a solar air heater. The experiments were conducted under the conditions of Tikrit-Iraq in December 2021 and January 2022. RT42 and RT50 were used as PCMs in two separate solar air heaters. Each PCM filled the thermal storage of SAH. A finned heat exchanger, in which air was forced through, was immersed in the thermal storage. Two arrangements were tested. In the first arrangement, the two SAHs were separated from each other. In the second arrangement, the two SAHs were connected in series, first the RT42 SAH and then the RT50 SAH. The results showed that the highest recorded temperature was for RT50, i.e., 59 °C, in the separation arrangement. Also, the solar air heater with RT50 in the series arrangement continued to heat the forced air until 5 AM the next day.
This study presents a numerical analysis of a laminar counter flow inside small channels plate heat exchanger fitted with Y and C shape obstacles. Using the Computational Fluid Dynamics CFD, an advanced and modern simulation technique, the influence of the geometrical parameters (such as geometry, rib pitch) on the flow characteristics, the thermal and the hydrodynamics performance of the PHE (plate heat exchanger) is investigated numerically. The main goal of this work is to increase the flow turbulence, enhance the heat transfer and the thermal efficiency by inserting new obstacles forms. The computational domain is a conjugate model which is developed by the Computer Aided Design CAD software Solidworks. The results, obtained with Ansys Fluent, show that the presence of the shaped ribs provides enhancement in heat transfer and fluid turbulence. The CFD analysis is validated with the previous study. The non-dimensional factors such as the Nusselt number Nu, the skin friction factor Cf and the thermo-hydraulic performance parameter THPP are predicted with a Reynolds number Re range of 200–800. The temperature and the velocity distribution are presented and analyzed. The Y ribs and the C ribs offer as maximum THPP values respectively about 1.44 and 2.6 times of a smooth duct.
This research paper presents a computational fluid dynamics (CFD) examination of plate heat exchangers (PHE) fitted with bionic ribbed labyrinthine patterns. Using a biomimetic approach, these novel designs (capsule, diamond, and willow leaf) were inspired by nature, viz., cockroach egg, diamond sturgeon fish, and willow tree leaf, respectively. With a Reynolds number Re range of 500-2500, this investigation aims to highlight the impact of the rib shape (capsule, diamond, and willow leaf) and rib arrangement: straight and inclined (α = 90° and α = 45°) on its effectiveness. Utilizing ANSYS Fluent and the standard k-ε model of turbulence, a mesh independence investigation was carried out to guarantee the precision and dependability of the computational technique. The validation of computing findings was conducted by comparison with prior experimental studies. The new design outperformed the typical chevron-type PHE specifically the willow leaf design which has boosts it by 62.4% in terms of the thermohydraulic performance parameter (THPP).