Kit Ming Lam

Dr. Kit Ming Lam


Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Atmospheric Environment
Verified
Journal Article
Closed access
XLX Li
X Li
CLC Liu
C Liu
DLD Leung
D Leung
KLKit Ming Lam
Kit Ming Lam

1 May 2008 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Closed access
KLKit Ming Lam
Kit Ming Lam
MLM.Y. H. Leung
M.Y. H. Leung
JZJ.G. Zhao
J.G. Zhao

1 July 2008 in Journal of Applied Meteorology and Climatology
Verified
Journal Article
Open access
Xianxiang LiXianxiang Li
Xianxiang Li
DLDennis Leung
Dennis Leung
CLChun-Ho Liu
Chun-Ho Liu
KLKit Ming Lam
Kit Ming Lam
The flow characteristics inside urban street canyons were studied in a laboratory water channel. The approaching flow direction was horizontal and perpendicular to the street axis. The street width was adjusted to form street canyons of aspect ratios 0.5, 1.0, and 2.0. The velocity field and turbulent intensity were measured with a laser Doppler anemometer at various locations within the street canyons, which were used to elucidate the flow pattern inside the street canyons. It was found that the previous numerical modeling results are in good agreement with the current experimental results at most locations. For the street canyon of aspect ratio 0.5, which belongs to the wake interference flow regime, the mean and fluctuating velocity components were more difficult to measure as compared with the other two cases because of its more complicated flow pattern. Some guidelines for numerical modeling were developed based on the measurement results. The data presented in this paper can also be used as a comprehensive database for the validation of numerical models.

1 January 2005 in European Journal of Mechanics - B/Fluids
Verified
Journal Article
Open access
KLKit Ming Lam
Kit Ming Lam
MLM.Y.H. Leung
M.Y.H. Leung
This paper reports an experimental investigation of the vortex shedding wake behind a long flat plate inclined at a small angle of attack to a main flow stream. Detailed velocity fields are obtained with particle-image velocimetry (PIV) at successive phases in a vortex shedding cycle at three angles of attack, α=20°, 25° and 30°, at a Reynolds number Re≈5,300. Coherent patterns and dynamics of the vortices in the wake are revealed by the phase-averaged PIV vectors and derived turbulent properties. A vortex street pattern comprising a train of leading edge vortices alternating with a train of trailing edge vortices is found in the wake. The trailing edge vortex is shed directly from the sharp trailing edge while there are evidences that the formation and shedding of the leading edge vortex involve a more complicated mechanism. The leading edge vortex seems to be shed into the wake from an axial location near the trailing edge. After shedding, the vortices are convected downstream in the wake with a convection speed roughly equal to 0.8 the free-stream velocity. On reaching the same axial location, the trailing edge vortex, as compared to the leading edge vortex, is found to possess a higher peak vorticity level at its centre and induce more intense fluid circulation and Reynolds stresses production around it. It is found that the results at the three angles of attack can be collapsed into similar trends by using the projected plate width as the characteristic length of the flow. © 2004 Elsevier SAS. All rights reserved.postprin

1 April 2011 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Open access
FXFeng Xiao
Feng Xiao
KLKit Ming Lam
Kit Ming Lam
XLX.Y. Li
X.Y. Li
RZR.S. Zhong
R.S. Zhong
XZX.H. Zhang
X.H. Zhang
Particle flocculation with chemical flocculant addition is an essential step in water treatment. The performance of flocculation and the property of the flocs formed affect the overall results of the treatment process. In addition to particulate impurities, the presence of organic matter in water, such as natural organic materials (NOM), also influence the effectiveness of chemical flocculation. In this paper, the PIV system was employed to investigate the flocculation dynamics for different flocculants in different model waters. With the PIV and image analysis, the change in particle size distribution could be well recorded. Using the sequence of flocculation, shear breakage and re-flocculation on a jar-test device together with the PIV system, the rate of floc formation, the strength of the flocs, the recovery of broken flocs, and the morphological and structural features of the flocs were characterized. The results indicated that the adsorption of HA on the particle will stabilized the particles, hence hindered the flocculation process. Sweep flocculation using a higher chemical coagulant dosage was an effective means of process enhancement for the removal of particulates and associated organic matter. The dynamics of A-B-R process was characterized by particle size distribution (PSD) measurement with PIV setup. The particle strength and reversibility capability were examined. Strength index showed the HA flocs have comparable strength, while recovery index indicated a less recovery capability with the increasing of HA concentration after exposure to a higher shear, especially for ferric HA flocs. It appears that the bonds holding HA flocs together are not purely physical bonds given the limited regrowth seen. Finally, evolution of floc structure during A-B-R process was analysed by investigated the fractal dimension Db. The results were generally consistent with previous PSD measurements. It suggested that the structure of flocs in breakage became more compact with little permeability. An increase in floc compaction provides a further explanation for the limited regrowth for most of flocs. According to the performances of alum and ferric, it can be noticed that HA flocs have different properties dependent on which chemical coagulant is used. Alum produced larger HA flocs which endured a higher recovery capability after exploring higher shear, hence, compared to ferric, it could be preferred to using in the practical enhanced coagulation unit.postprin

1 May 2011 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Open access
KLKit Ming Lam
Kit Ming Lam
JZJ.G. Zhao
J.G. Zhao
MLM.Y.H. Leung
M.Y.H. Leung
This paper studies wind-induced interference effects on a row of five square-plan tall buildings arranged in close proximity. Mean and fluctuating wind loads are measured on each building member and wind-induced dynamic responses of the building are estimated with the high-frequency force-balance technique. The modifications of building responses from interference over a practical range of reduced velocities are represented by an envelope interference factor. Wind tunnel experiments and response analysis are carried out under all possible angles of wind incidence, at four different building separation distances, and for two arrangement patterns of buildings in the row, that is the parallel and diamond patterns. It is found that building interference leads to amplified dynamic responses in many cases but reduction in responses also occurs at some wind incidence. For a building row of the parallel pattern, five distinct wind incidence sectors of different levels and mechanisms of interference effect can be identified. The largest values of envelope interference factors can reach 2.4 for the torsional responses. When the row of tall buildings is arranged in the diamond pattern, increase in wind excitation occurs at many wind angles due to a "wind catchment" effect. The interference factors have larger peak values, reaching 2.1 in the sway directions and above 4 in torsion. However, all large amplifications of building responses do not occur in the situations of peak resonant dynamic responses of the single isolated building. Thus, the design values of peak dynamic responses of a tall building are not significantly magnified when placed in a row. © 2011 Elsevier Ltd.postprin