Nobutake Nakatani

Dr. Nobutake Nakatani

Department of Environmental Sciences, Rakuno Gakuen University, Ebetsu, Hokkaidō, Japan
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2012 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
NNNobutake Nakatani
Nobutake Nakatani
DKDaisuke Kozaki
Daisuke Kozaki
MMMasanobu Mori
Masanobu Mori
KTKazuhiko Tanaka
Kazuhiko Tanaka
One of the ultimate goals of ion chromatography is to determine both anions and cations found in samples with a single chromatographic run. In the present article, recent progress in ion-exclusion/ion-exchange chromatography for the simultaneous determinations of inorganic anions and cations are reviewed. Firstly, the principle and the control for the simultaneous separation and detection of analyte ions using ion-exclusion/cation-exchange chromatography with a weakly acidic cation-exchange column are outlined. Then, advanced chromatographic techniques in terms of analytical time, selectively and sensitivity are summarized. As a related method, ion-exclusion/anion-exchange chromatography with an anion-exchange column could be used for the simultaneous determination of inorganic nitrogen species, such as ammonium, nitrite and nitrate ions. Their usefulness and applications to water-quality monitoring and related techniques are also described.

10 May 2011 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
NNNobutake Nakatani
Nobutake Nakatani
DKDaisuke Kozaki
Daisuke Kozaki
MMMasanobu Mori
Masanobu Mori
KHKiyoshi Hasebe
Kiyoshi Hasebe
NNNobukazu Nakagoshi
Nobukazu Nakagoshi
KTKazuhiko Tanaka
Kazuhiko Tanaka
Simultaneous determinations of common inorganic anionic species (SO42−, Cl−, NO3−, phosphate and silicate) and cations (Na+, NH4+, K+, Mg2+ and Ca2+) were conducted using an ion-chromatography system with dual detection of conductivity and spectrophotometry in tandem. The separation of ionic species on a weakly acidic cation-exchange resin was accomplished using a mixture of 100 mM ascorbic acid and 4 mM 18-crown-6 as an acidic eluent (pH 2.6), after which the ions were detected using a conductivity detector. Subsequently, phosphate and silicate were analyzed based on derivatization with molybdate and spectrophotometry at 700 nm. The detection limits at S/N = 3 ranged from 0.11 to 2.9 μM for analyte ionic species. This method was applied to practical river water and wastewater with acceptable criteria for the anion-cation balance and comparisons of the measured and calculated electrical conductivity, demonstrating the usefulness of the present method for water quality monitoring.

4 July 2014 in Water
Verified
Journal Article
Open access
PDF file
DKDaisuke Kozaki
Daisuke Kozaki
TOTakashi Ozaki
Takashi Ozaki
NNNobutake Nakatani
Nobutake Nakatani
MMMasanobu Mori
Masanobu Mori
KTKazuhiko Tanaka
Kazuhiko Tanaka
We evaluated the use of ion-exclusion chromatographic systems for analyzing the behavior of inorganic ions (e.g., bicarbonate, sulfate, chloride, nitrate, phosphate, dissolved silicate, sodium, ammonium, potassium, magnesium, and calcium ions) in a suburban river located in Jakarta, Indonesia. Carbonate, phosphate, and silicate ion concentrations were determined using ion-exclusion chromatography (IEC) on a weakly acidic cation-exchange resin column (WCX) in the H+-form with water eluent. Other ions were identified by ion-exclusion/cation-exchange chromatography (IEC/CEC) on a WCX column with tartaric acid eluent. The use of IEC systems for water quality monitoring was advantageous for the following reasons: (1) the concentrations of analyte ions, except NO3− and silicate ions, increased from upstream to downstream; and (2) the speciation of inorganic nitrogen ions could be analyzed by single injection into the IEC/CEC. The IEC approach provided beneficial information for the construction of sewage treatment facilities in our study area. Results showed that (1) the analyte concentrations for samples obtained in the downstream area were higher than those in the upstream area owing to contamination by domestic sewage; (2) the concentrations of NO3− and NH4+ correlated with the concentration of dissolved oxygen; and (3) bicarbonate concentrations increased downstream, likely due to respiration of bacteria and dissolution of concrete under low-oxygen conditions.

1 January 2001 in Environmental Pollution
Verified
Journal Article
Closed access
AKAtsushi Kume
Atsushi Kume
NTN Tsuboi
N Tsuboi
NNNobutake Nakatani
Nobutake Nakatani
KNK Nakane
K Nakane
NSN Sakurai
N Sakurai
HSH Sakugawa
H Sakugawa

23 April 2017 in Environments
Verified
Journal Article
Open access
PDF file
DKDaisuke Kozaki
Daisuke Kozaki
NHNorhasmira Idayu Binti Harun
Norhasmira Idayu Binti Harun
MRMohd Hasbi Ab. Rahim
Mohd Hasbi Ab. Rahim
MMMasanobu Mori
Masanobu Mori
NNNobutake Nakatani
Nobutake Nakatani
KTKazuhiko Tanaka
Kazuhiko Tanaka
Water quality of the Galing River in Kuantan, Malaysia was examined to understand the anthropogenic environmental load in each administrative section, using water quality monitoring data and land use pattern. The National Physical Plan 2005 identified Kuantan as one of the country’s future growth centers, which has resulted in rapid development and environmental degradation in the past decade. Multiple water quality indexes used by the Department of Environment, Malaysia and concentrations of several ionic species were examined to assess the river’s water quality. The following inferences were drawn in this study: (1) Cl− and Na+ concentrations indicated that the basin area near the eastern urbanized area was subject to lesser human influence and lower environmental burden; (2) the Western side of the Galing River was subject to higher anthropogenic influence and indicated lower class levels of ammoniacal nitrogen, chemical oxygen demand, and dissolved oxygen, compared to the eastern side; (3) Class V or near class V pH values were obtained upstream at the western side of the Galing River in the industrial area; (4) Two types of environmental burden were identified in the western side of the Galing River, namely, inflow of industrial wastewater upstream on the western side and the effect of household wastewater or untreated raw sewage wastewater.

8 March 2016 in Separations
Verified
Journal Article
Open access
PDF file
YOYu Otsuka
Yu Otsuka
NNNobutake Nakatani
Nobutake Nakatani
TTTakuya Takahashi
Takuya Takahashi
DKDaisuke Kozaki
Daisuke Kozaki
MMMasanobu Mori
Masanobu Mori
KTKazuhiko Tanaka
Kazuhiko Tanaka
The simple and simultaneous determination of silicic, boric and carbonic acids was made using ion-exclusion chromatography (IEC) and a Corona™ charged aerosol detector (C-CAD). Silicic and boric acids were separated by the column packed with a weakly acidic cation-exchange resin in H+-form and ultra-pure water eluent, and the detector responses were improved by the addition of acetonitrile to eluent. Under the optimized conditions, the simultaneous determination of weak inorganic acids, except for carbonic acid, was successfully performed. When the conversion column packed with a strong acidic cation-exchange resin in Na+- or K+-form was inserted between the separation column and the detector, weak inorganic acids including carbonic acid could be detected by the C-CAD. The calibration curves were linear in the range of 0.5–10 mg·L−1 as Si for silicic acid (r2 = 0.996), 10–100 mg·L−1 as B for boric acid (r2 = 0.998) and 1.3–21 mg·L−1 as C for carbonic acid (r2 = 0.993). The detection limits based on three times the standard deviation were 0.03 mg·L−1 as Si for silicic acid, 0.40 mg·L−1 as B for boric acid and 0.08 mg·L−1 as C for carbonic acid. This method was applicable to river, hot spring and drinking water.