Tao Zhao

Dr. Tao Zhao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XZXing Zhang
Xing Zhang
YHYuhua Hu
Yuhua Hu
WMWang Mao
Wang Mao
TZTao Zhao
Tao Zhao
MWMingda Wang
Mingda Wang
RCRenxian Cao
Renxian Cao
The cascaded H-Bridge (CHB) converter is a favorable candidate in the photovoltaic (PV) field due to its modular multilevel construction, which could pursue the maximum energy yield by adopting the maximum power point tracking (MPPT) strategy. However, with the increasing penetration of PV generation, challenges are arisen for the grid stability due to the deficiency of converter inertia and damping. To improve the system inertia besides the energy efficiency, this paper proposes a control strategy for the CHB converter with the combination of MPPT and virtual synchronous generator (VSG). Taking advantage of the modularity of CHB converter, a proportion of the total PV power is reserved by the selected reserved cells to provide the power buffer between the VSG and PV power for grid frequency supporting, and the non-reserved cells are utilizing the MPPT to ensure the energy efficiency. With the proposed control strategy, the CHB converter could be equipped with the frequency regulation capacity without energy storage device and the full use of PV power is realized, which are verified by the simulation and experimental results.

16 March 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TZTao Zhao
Tao Zhao
XZXing Zhang
Xing Zhang
WMWang Mao
Wang Mao
FWFusheng Wang
Fusheng Wang
JXJun Xu
Jun Xu
XWXinyu Wang
Xinyu Wang
Due to the unequal solar radiations or dust accumulation of photovoltaic modules in a single-phase cascaded H-bridge photovoltaic inverter, the unbalanced output power among photovoltaic modules will make the H-bridges with higher power overmodulation, resulting in deteriorated grid current. Concerning this issue, this paper proposes an optimized third harmonic compensation strategy that injects moderate amount of third harmonic into the overmodulation H-bridges to keep the amplitudes of their modulation waveforms just being unity, then compensates the same amount of opposite harmonic sequence and properly distributes it to rest of the H-bridges. The proposed method can ensure that all the power units will be free from overmodulation under some heavy power imbalance conditions and will not increase the third harmonic component of the grid current. The validity and effectiveness of the proposed method is verified by simulation and experimental results.

25 February 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TZTao Zhao
Tao Zhao
DCDaolian Chen
Daolian Chen
With the characteristics of module-level maximum power point tracking, module-level monitoring, and panel shut- off , single-phase cascaded H-bridge (CHB) inverter has outstanding advantages applied to household photovoltaic (PV) power generation occasion. However, unbalanced output powers among PV panels is an inherent problem of single-phase CHB PV inverter, which will make the H-bridges (HBs) with higher powers overmodulation, resulting in deteriorated grid current and even system instability. Aiming at this issue, this article proposes a power adaptive control strategy, which divides system operation into three modes, and calculates modulation waveforms by using different methods in different modes. By flexibly adjusting the transmission power of HBs in different modes, all the HBs are able to avoid overmodulation, and single-phase CHB PV grid-connected inverter can still operate normally even if the maximum powers among PV panels are seriously unbalanced. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

25 April 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YHYuhua Hu
Yuhua Hu
XZXing Zhang
Xing Zhang
WMWang Mao
Wang Mao
TZTao Zhao
Tao Zhao
FWFusheng Wang
Fusheng Wang
ZDZhiqiang Dai
Zhiqiang Dai
Due to different solar radiation, temperature and other reasons of modules in the three-phase cascaded H-bridge (CHB) photovoltaic (PV) inverter, the output power among PV modules will be unequal and lead to unbalanced grid currents, which cannot meet the requirements of grid codes. On the other hand, the second order voltage ripple is aroused in the DC-link capacitor since each phase-leg of the CHB inverter is made up of a single-phase inverter. Concerning these two issues, this paper proposes an optimized third harmonic injection method based on fundamental frequency zero sequence injection (FFZSI), which is a conventional method to handle the slight power imbalance problem. In this paper, the FFZSI is adopted to redistribute the power among three phases, and then the third harmonic is injected into the three-phase combined reference waveforms according to the two requirements: all modules are free from overmodulation and the DC-link voltage fluctuation is mostly reduced. Therefore, the proposed method can reduce the DC-link voltage fluctuation and extend the power balance range of FFZSI at the same time. The validity and effectiveness of the proposed method are verified by simulation and experimental results.

1 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MWMingda Wang
Mingda Wang
XZXing Zhang
Xing Zhang
TZTao Zhao
Tao Zhao
MMMingyao Ma
Mingyao Ma
YHYuhua Hu
Yuhua Hu
XWXinyu Wang
Xinyu Wang
Cascaded H-bridge (CHB) inverter has the advantages of easy modularization, the low harmonic content of output current, and that all power units are capable of achieving independent MPPT. However, aging or partial shielding of photovoltaic (PV) panels will lead to the unbalanced output power of each PV module, which will result in the overmodulation of H-bridges (HBs) and increased harmonic components of the grid current. In this paper, a novel harmonic compensation strategy for single-phase CHB inverter is proposed, it can extend the linear modulation range of single-phase CHB inverters to about 1.27. Moreover, this strategy will not reduce energy harvesting, and also can maintain the system to operate in the unit power factor. Simulation and experimental results all verify the effectiveness of the proposed strategy.

20 May 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DCDaolian Chen
Daolian Chen
TZTao Zhao
Tao Zhao
SXSong Xu
Song Xu
A circuit structure, topological family, and unipolar phase-shift SPWM master-slave power distribution energy management control strategy (EMCS) of the single-stage Buck type multi-input high-frequency (HF) link's inverters with multiwinding time-sharing power supply are proposed in this article, in order to reduce the power conversion stage, volume and weight, and increase conversion efficiency and reliability. The key technologies of this kind of inverter, such as circuit structure and topological family, EMCS, power supply mode (PSM), and steady-state principle characteristics, are deeply studied. The circuit structure is composed of multiple isolated HF inverting bridges, a HF transformer with multi-input single-output, a cycloconverter and an output LC filter. The EMCS is to generate the bipolar tristate multilevel SPWM waves by phase-shift between the right arm and the left arm of multiple HF inverting bridges; the cycloconverter demodulates it into the unipolar tristate multilevel SPWM wave, and performs zero voltage commutation. The experimental results of the designed and developed 1kVA multi-input inverter prototype have shown it has the advantages of single-stage power conversion, HF electrical isolation, high conversion efficiency, small volume and weight, high reliability, stable output voltage, multi-input source master-slave power distribution, and smooth switching of different PSMs.