Riccardo Cicchi

Dr. Riccardo Cicchi

1. National Institute of Optics National Research Council (CNR-INO), Largo Fermi 6, 50125 Firenze, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2009 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
Riccardo CicchiRiccardo Cicchi
Riccardo Cicchi
DKDimitrios Kapsokalyvas
Dimitrios Kapsokalyvas
VGVincenzo de Giorgi
Vincenzo de Giorgi
VMVincenza Maio
Vincenza Maio
AWAnnelies Van Wiechen
Annelies Van Wiechen
FPFrancesco Saverio Pavone
Francesco Saverio Pavone
We have used nonlinear imaging to evaluate collagen organization in connective tissue ex‐vivo samples. Image analysis methods were tested on healthy dermis, normal scars, and keloids. The evaluation of the second harmonic to autofluorescence aging index of dermis (SAAID) has allowed a first characterization of tissues by scoring the collagen/elastin content. Further analyses on collagen morphology in healthy dermis and keloids were performed by image‐pattern analysis of SHG images. The gray‐level co‐occurrence matrix (GLCM) analysis method has allowed classification of different tissues based on the evaluation of geometrical arrangement of collagen fibrillar bundles, whereas a pattern analysis of the FFT images has allowed the discrimination of different tissues based on the anisotropy of collagen fibers distribution. This multiple scoring method represents a promising tool to be extended to other collagen disorders, as well as to be used in in‐vivo skin‐imaging applications.

12 July 2012 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
Riccardo CicchiRiccardo Cicchi
Riccardo Cicchi
NVNadine Vogler
Nadine Vogler
DKDimitrios Kapsokalyvas
Dimitrios Kapsokalyvas
BDBenjamin Dietzek
Benjamin Dietzek
JPJürgen Popp
Jürgen Popp
FPFrancesco Saverio Pavone
Francesco Saverio Pavone
Second‐harmonic generation (SHG) microscopy is a fantastic tool for imaging collagen and probing its hierarchical organization from molecular scale up to tissue architectural level. In fact, SHG combines the advantages of a non‐linear microscopy approach with a coherent modality able to probe molecular organization. In this manuscript we review the physical concepts describing SHG from collagen, highlighting how this optical process allows to probe structures ranging from molecular sizes to tissue architecture, through image pattern analysis and scoring methods. Starting from the description of the most relevant approaches employing SHG polarization anisotropy and forward – backward SHG detection, we then focus on the most relevant methods for imaging and characterizing collagen organization in tissues through image pattern analysis methods, highlighting advantages and limitations of the methods applied to tissue imaging and to potential clinical applications.

21 December 2005 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
Marco CapitanioMarco Capitanio
Marco Capitanio
MCM. Canepari
M. Canepari
PCP. Cacciafesta
P. Cacciafesta
VLV. Lombardi
V. Lombardi
Riccardo CicchiRiccardo Cicchi
Riccardo Cicchi
RBR. Bottinelli
R. Bottinelli
During skeletal muscle contraction, regular arrays of actin and myosin filaments slide past each other driven by the cyclic ATP-dependent interaction of the motor protein myosin II (the cross-bridge) with actin. The rate of the cross-bridge cycle and its load-dependence, defining shortening velocity and energy consumption at the molecular level, vary widely among different isoforms of myosin II. However, the underlying mechanisms remain poorly understood. We have addressed this question by applying a single-molecule approach to rapidly (≈300 μs) and precisely (≈0.1 nm) detect acto-myosin interactions of two myosin isoforms having large differences in shortening velocity. We show that skeletal myosin propels actin filaments, performing its conformational change (working stroke) in two steps. The first step (≈3.4–5.2 nm) occurs immediately after myosin binding and is followed by a smaller step (≈1.0–1.3 nm), which occurs much faster in the fast myosin isoform than in the slow one, independently of ATP concentration. On the other hand, the rate of the second phase of the working stroke, from development of the latter step to dissociation of the acto-myosin complex, is very similar in the two isoforms and depends linearly on ATP concentration. The finding of a second mechanical event in the working stroke of skeletal muscle myosin provides the molecular basis for a simple model of actomyosin interaction. This model can account for the variation, in different fiber types, of the rate of the cross-bridge cycle and provides a common scheme for the chemo-mechanical transduction within the myosin family.

13 March 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPaolo Matteini
Paolo Matteini
FRFulvio Ratto
Fulvio Ratto
Francesca RossiFrancesca Rossi
Francesca Rossi
Riccardo CicchiRiccardo Cicchi
Riccardo Cicchi
CSChiara Stringari
Chiara Stringari
RPRoberto Pini
Roberto Pini
The loss of organization of the corneal collagen lattice induced by photothermal effects was analyzed by using second-harmonic generation (SHG) imaging. Porcine cornea samples were treated with low-power laser irradiation in order to get localized areas of tissue disorganization. The disorder induced within the irradiated area of corneal stroma was quantified by means of Discrete Fourier Transform, auto-correlation and entropy analyses of the SHG images. Polarization modulated SHG measurements allowed to probe the changes in the structural anisotropy of sub-micron hierarchical levels of the stromal collagen. Our results emphasize the great potential of the SHG imaging to detect subtle modifications in the collagen assembly. The proposed analytical methods may be used to track several genetic, pathologic, accidental or surgical-induced disorder states of biological tissues.

28 August 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MLMassimiliano Locatelli
Massimiliano Locatelli
MRMARCO RAVARO
MARCO RAVARO
SBSaverio Bartalini
Saverio Bartalini
LCLuigi Consolino
Luigi Consolino
MVMiriam S. Vitiello
Miriam S. Vitiello
PNPaolo De Natale
Paolo De Natale
Coherent imaging in the THz range promises to exploit the peculiar capabilities of these wavelengths to penetrate common materials like plastics, ceramics, paper or clothes with potential breakthroughs in non-destructive inspection and quality control, homeland security and biomedical applications. Up to now, however, THz coherent imaging has been limited by time-consuming raster scanning, point-like detection schemes and by the lack of adequate coherent sources. Here, we demonstrate real-time digital holography (DH) at THz frequencies exploiting the high spectral purity and the mW output power of a quantum cascade laser combined with the high sensitivity and resolution of a microbolometric array. We show that, in a one-shot exposure, phase and amplitude information of whole samples, either in reflection or in transmission, can be recorded. Furthermore, a 200 times reduced sensitivity to mechanical vibrations and a significantly enlarged field of view are observed, as compared to DH in the visible range. These properties of THz DH enable unprecedented holographic recording of real world dynamic scenes.

1 January 2005 in Optics Express
Verified
Journal Article
Closed access
PDF file
Riccardo CicchiRiccardo Cicchi
Riccardo Cicchi
FPFrancesco Saverio Pavone
Francesco Saverio Pavone
DMD. Massi
D. Massi
DSDavid Sampson
David Sampson
We investigate the application of hyperosmotic optical clearing agents to improve the image contrast and penetration depth in two-photon microscopy of human dermis ex vivo. We show that the agents glycerol, propylene glycol, and glucose all convey significant improvements and we provide results on their dynamic behaviour and the reversibility of the effect. At suitable concentrations, such agents have the potential to be compatible with living tissue and may possibly enhance in-vivo deep-tissue imaging.