Christoph Kellner

Mr. Christoph Kellner


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
HMHelena Milavec
Helena Milavec
CKChristoph Kellner
Christoph Kellner
NRNivetha Ravikumar
Nivetha Ravikumar
CAChristoph E. Albers
Christoph E. Albers
TLTill Dominic Lerch
Till Dominic Lerch
LBLorin M. Benneker
Lorin M. Benneker
Carbon fibre reinforced polyether ether ketone (CFR-PEEK) is a suitable material to replace metal implants in orthopaedic surgery. The radiolucency of CFR-PEEK allows an optimal visualisation of the bone and soft tissue structures. We aimed to assess the performance and radiological and clinical outcomes of anterior cervical discectomy and fusion (ACDF) with CFR-PEEK anterior cervical plating (ACP) under first use clinical conditions. We retrospectively studied the prospectively-collected data of 42 patients who underwent ACDF with CFR-PEEK ACP between 2011 and 2016. We assessed clinical outcome (Odom’s criteria, complications) and radiological parameters (global and segmental cervical lordosis, Bridwell score for fusion, adjacent segment degeneration) preoperatively, immediately post-operatively, and after a 12-month follow-up period. Patients’ satisfaction was excellent, good, fair, and poor in 12, 19, 3, and 1 patients, respectively. Two patients developed dysphagia. No hardware failure occurred. Compared with preoperative radiographs, we observed a gain of global cervical lordosis and segmental lordosis (7.4 ± 10.1 and 5.6 ± 7.1 degrees, respectively) at the 12-month follow-up. Bridwell IF grades I, II, and III were observed in 22, 6, and 7 patients, respectively. The 12-month adjacent segment degeneration-free and adjacent segment disease-free survival rates were 93.1% and 96.3%, respectively. We observed a dysphagia rate of 5.7% and a reoperation rate of 4.8%. In conclusion, CFR-PEEK ACP shows positive outcomes in terms of implant safety, restoration of cervical lordosis, and functional recovery, and is suitable for ACDF.

17 May 2019 in Preprints.org
Verified
Preprint
Open access
PDF file
HMHelena Milavec
Helena Milavec
CKChristoph Kellner
Christoph Kellner
NRNivetha Ravikumar
Nivetha Ravikumar
TLTill Dominic Lerch
Till Dominic Lerch
SHSven Hoppe
Sven Hoppe
LBLorin M. Benneker
Lorin M. Benneker
Carbon fibre reinforced polyetheretherketone (CFR-PEEK) is a suitable material to replace metal implants in orthopaedic surgery. The radiolucency allows optimal visualization of bone and soft tissue. We aimed to assess performance and radiological and clinical outcomes of anterior cervical discectomy and fusion (ACDF) with CFR-PEEK anterior cervical plating (ACP) under first use clinical conditions. We retrospectively studied data of 42 patients undergoing ACDF with CFR-PEEK ACP between 2011 and 2016. We assessed clinical and radiological parameters preoperatively, immediately post-operative and after a 12-month follow-up period. Patients’ satisfaction was excellent, good, fair and poor in 12, 19, 3, and 1 respectively. 2 patients developed dysphagia. No hardware failure occurred. Compared to preoperative radiographs, we observed a gain of global cervical lordosis and segmental lordosis (7.4±10.1 and 5.6±7.1 degrees respectively) at 12-month follow-up. Bridwell interbody fusion grades I, II, and III were observed in 22, 6, and 7 Pts respectively. The 12-month adjacent segment degeneration-free and adjacent segment disease-free survival rates were 93.1% and 96.3% respectively. In conclusion, CFR-PEEK ACP shows positive outcomes in terms of implant safety, radiological outcomes and functional recovery and is suitable for ACDF in trauma, degenerative disease and tumours. Radiolucency and the absence of imaging artefacts enable precise radiological follow-up.