Yu Cheng

Dr. Yu Cheng

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2022 in Journal of Hydrology
Verified
Journal Article
Closed access
YLYiping Li
Yiping Li
YHYanan Huang
Yanan Huang
DJDaobin Ji
Daobin Ji
YCYu Cheng
Yu Cheng
ANAmechi S. Nwankwegu
Amechi S. Nwankwegu
JLJinhua Li
Jinhua Li

30 December 2018 in Environmental Science & Technology
Verified
Journal Article
Closed access
YCYu Cheng
Yu Cheng
JDJue Ding
Jue Ding
老谢老师 谢
老师 谢
XJXiaowen Ji
Xiaowen Ji
YZYoukuan Zhang
Youkuan Zhang

6 April 2020 in Environmental Science & Technology
Verified
Journal Article
Closed access
YCYu Cheng
Yu Cheng
JDJue Ding
Jue Ding
XLXiuyu Liang
Xiuyu Liang
XJXiaowen Ji
Xiaowen Ji
LXLing Xu
Ling Xu
YZYou-Kuan Zhang
You-Kuan Zhang

5 April 2023 in Free Radical Biology and Medicine
Verified
Journal Article
Closed access
YCYu Cheng
Yu Cheng
BHBing-Hao Hou
Bing-Hao Hou
GXGui-Lin Xie
Gui-Lin Xie
YSYa-Ting Shao
Ya-Ting Shao
JYJie Yang
Jie Yang
琛徐琛 徐
琛 徐

JDJue Ding
Jue Ding
YCYu Cheng
Yu Cheng
ZHZulin Hua
Zulin Hua
CYCong Yuan
Cong Yuan
XWXiaoju Wang
Xiaoju Wang
Endocrine-disrupting chemicals (EDCs) that exist in the aquatic system bring severe environmental risks. In this study, we investigate the dissolved organic matter (DOM) effect on the release and distribution of EDCs under varied hydrodynamic conditions. A water chamber mesocosm was designed to simulate the hydrodynamic forces in a shallow lake. The contents of bisphenol A (BPA) and nonylphenol (NP) in colloid-bound and soluble phases were measured under four increasing hydrodynamic intensities that were 5%, 20%, 50%, and 80% of the critical shear stress. The total BPA and NP contents in overlying water grew linearly with the hydrodynamic intensity (R2 = 0.997 and 0.987), from 108.28 to 415.92 ng/L of BPA and 87.73 to 255.52 ng/L of NP. The exponential relationships of EDC content and hydrodynamic intensity in soluble phase (R2 = 0.985 of BPA and 0.987 of NP) and colloid phase (R2 = 0.992 of BPA and 0.995 of NP) were also detected. The DOM concentrations in colloid-bound phase (cDOM) and in soluble phase (sDOM) were measured and the linear relationships with BPA content (R2 = 0.967 of cDOM and 0.989 of sDOM) and NP content (R2 = 0.978 of cDOM and 0.965 of sDOM) were detected. We analyzed the ratio (αDOM) of sDOM and cDOM that grew logarithmically with the hydrodynamic intensity (R2 = 0.999). Moreover, the ratio (αEDCs) of BPA and NP contents in soluble and colloid-bound phases varied differently with αDOM. The results suggested that BPA tended to be in the soluble phase and NP tended to be in the colloid-bound phase due to the increasing value of αDOM.

24 March 2010 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
LGLisa A. Graham
Lisa A. Graham
ATAnthony Tong
Anthony Tong
GPGary Poole
Gary Poole
LDLuyi Ding
Luyi Ding
FKFu Ke
Fu Ke
JBJeffrey R. Brook
Jeffrey R. Brook
Direct thermal desorption-gas chromatography-mass spectrometry (DTD-GC-MS) is a technique that is finding application in the characterisation of the semivolatile organic carbon fraction of ambient and combustion source particulate matter (PM) collected on filters. In this study, three DTD-GC-MS methods were assessed and compared to a conventional solvent extraction method for analysis of a mixture of target analytes in solution and of diesel PM collected on quartz filters. The target analytes included n-alkanes, hopanes, steranes and polycyclic aromatic hydrocarbons. This study showed that while the three DTD-GC-MS methods were generally comparable to the solvent extraction method, (1) the choice of calibration strategy and calibration materials has a significant impact on the measured accuracy of a method; (2) very large variations were seen in all methods for the more volatile compounds such as C10 to C13 n-alkanes and naphthalene; (3) accuracy, defined as difference from the known concentration of a liquid sample, ranged from 5% to 32%; (4) precision, defined as the relative standard deviation, ranged from 4% to 16%. The average difference of DTD-GC-MS results from the solvent extraction results for the diesel PM filters ranged from 20% to 40%. This difference was driven by the large number of target analytes present at relatively low concentrations (<25 pg/mm2) and their corresponding higher variability. Differences in performance among the compound classes were noted. Minimum detection limits for the DTD-GC-MS methods were on the order of 0.1 to 1 pg/mm2 and were as good as or better than those obtained for the solvent extraction method.