The aim of this study was to develop a procedure for medical tool path planning in minimally-invasive knee surgery. The collision-free paths for the tool were obtained using the control locations method with a hybrid optimization strategy. The tool and knee elements were described with surface meshes. The knee model allowed for bones displacement and variable incision size and location. The proposed procedure was proven to be effective in path planning for minimally-invasive surgery. It can serve as a valuable aid in surgery planning and may also be used in systems for autonomous or semi-autonomous knee surgery.
Recent studies in biomechanical modeling suggest a paradigm shift, in which the parameters of biomechanical models would no longer treated as fixed values but as random variables with, often unknown, distributions. In turn, novel and efficient numerical methods will be required to handle such complicated modeling problems. The main aim of this study was to introduce and verify genetic algorithm for analyzing uncertainty in biomechanical modeling. The idea of the method was to encode two adversarial models within one decision variable vector. These structures would then be concurrently optimized with the objective being the maximization of the difference between their outputs. The approach, albeit expensive numerically, offered a general formulation of the uncertainty analysis, which did not constrain the search space. The second aim of the study was to apply the proposed procedure to analyze the uncertainty of an ankle joint model with 43 parameters and flexible links. The bounds on geometrical and material parameters of the model were set to 0.50 mm and 5.00% respectively. The results obtained from the analysis were unexpected. The two obtained adversarial structures were almost visually indistinguishable and differed up to 38.52% in their angular displacements.
The ankle is one of the most complicated joints in the human body. Its features a plethora of elements with complex behavior. Their functions could be better understood using a planar model of the joint with low parameter count and low numerical complexity. In this study, an accurate planar model of the ankle with optimized material parameters was presented. In order to obtain the model, we proposed an optimizational approach, which fine-tuned the material parameters of two-dimensional links substituting three-dimensional ligaments of the ankle. Furthermore, the cartilage in the model was replaced with Hertzian contact pairs. The model was solved in statics under moment loads up to 5 Nm. The obtained results showed that the structure exhibited angular displacements in the range of the ankle joint and that their range was higher in dorsiflexion than plantarflexion. The structure also displayed a characteristic ramp up of the angular stiffness. The results obtained from the optimized model were in accordance with the experimental results for the ankle. Therefore, the proposed method for fine-tuning the material parameters of its links could be considered viable.
8 January 2018 in The International Journal of Medical Robotics and Computer Assisted Surgery
Typical artificial joints for humanoid robots use actual human body joints only as an inspiration. The load responses of these structures rarely match those of the corresponding joints, which is important when applying the robots in environments tailored to humans. In this study, we proposed a novel, automated method for designing substitutes for a human intervertebral joint. The substitutes were considered as two platforms, connected by a set of flexible links. Their structural and material parameters were obtained through optimization with a structured Genetic Algorithm, based on the reference angular stiffnesses. The proposed approach was tested in three numerical scenarios. In the first test, a mechanism with angular stiffnesses corresponded to the actual L4–L5 intervertebral joint. Scenarios 2 and 3 featured mechanisms with geometry and structure comparable to the joint, but with custom stiffness profiles. The obtained results proved the effectiveness of the proposed method. It could be employed in the design of artificial joints for humanoid robots and orthotic structures for the human spine. As the approach is general, it could also be extended to different body joints.