Emre Ertin

Prof. Emre Ertin

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2015
Verified
Conference Paper
Open access
KHKaren Hovsepian
Karen Hovsepian
MAMustafa Al'Absi
Mustafa Al'Absi
EEEmre Ertin
Emre Ertin
TKThomas Kamarck
Thomas Kamarck
MNMotohiro Nakajima
Motohiro Nakajima
SKSantosh Kumar
Santosh Kumar
Recent advances in mobile health have produced several new models for inferring stress from wearable sensors. But, the lack of a gold standard is a major hurdle in making clinical use of continuous stress measurements derived from wearable sensors. In this paper, we present a stress model (called cStress) that has been carefully developed with attention to every step of computational modeling including data collection, screening, cleaning, filtering, feature computation, normalization, and model training. More importantly, cStress was trained using data collected from a rigorous lab study with 21 participants and validated on two independently collected data sets --- in a lab study on 26 participants and in a week-long field study with 20 participants. In testing, the model obtains a recall of 89% and a false positive rate of 5% on lab data. On field data, the model is able to predict each instantaneous self-report with an accuracy of 72%.

1 September 2015
Verified
Conference Paper
Closed access
NSNazir Saleheen
Nazir Saleheen
AAAmin Ahsan Ali
Amin Ahsan Ali
SHSyed Monowar Hossain
Syed Monowar Hossain
HSHillol Sarker
Hillol Sarker
SCSoujanya Chatterjee
Soujanya Chatterjee
SKSantosh Kumar
Santosh Kumar

1 April 2014
Verified
Conference Paper
Closed access
SHSyed Monowar Hossain
Syed Monowar Hossain
AAAmin Ahsan Ali
Amin Ahsan Ali
MRMahbubur Rahman
Mahbubur Rahman
EEEmre Ertin
Emre Ertin
DEDavid Epstein
David Epstein
SKSantosh Kumar
Santosh Kumar
A variety of health and behavioral states can potentially be inferred from physiological measurements that can now be collected in the natural free-living environment. The major challenge, however, is to develop computational models for automated detection of health events that can work reliably in the natural field environment. In this paper, we develop a physiologically-informed model to automatically detect drug (cocaine) use events in the free-living environment of participants from their electrocardiogram (ECG) measurements. The key to reliably detecting drug use events in the field is to incorporate the knowledge of autonomic nervous system (ANS) behavior in the model development so as to decompose the activation effect of cocaine from the natural recovery behavior of the parasympathetic nervous system (after an episode of physical activity). We collect 89 days of data from 9 active drug users in two residential lab environments and 922 days of data from 42 active drug users in the field environment, for a total of 11,283 hours. We develop a model that tracks the natural recovery by the parasympathetic nervous system and then estimates the dampening caused to the recovery by the activation of the sympathetic nervous system due to cocaine. We develop efficient methods to screen and clean the ECG time series data and extract candidate windows to assess for potential drug use. We then apply our model on the recovery segments from these windows. Our model achieves 100% true positive rate while keeping the false positive rate to 0.87/day over (9+ hours/day of) lab data and to 1.13/day over (11+ hours/day of) field data.

12 September 2016
Verified
Conference Paper
Open access
SCSoujanya Chatterjee
Soujanya Chatterjee
KHKaren Hovsepian
Karen Hovsepian
HSHillol Sarker
Hillol Sarker
NSNazir Saleheen
Nazir Saleheen
MAMustafa Al'ABsi
Mustafa Al'ABsi
SKSantosh Kumar
Santosh Kumar
Craving usually precedes a lapse for impulsive behaviors such as overeating, drinking, smoking, and drug use. Passive estimation of craving from sensor data in the natural environment can be used to assist users in coping with craving. In this paper, we take the first steps towards developing a computational model to estimate cigarette craving (during smoking abstinence) at the minute-level using mobile sensor data. We use 2,012 hours of sensor data and 1,812 craving self-reports from 61 participants in a smoking cessation study. To estimate craving, we first obtain a continuous measure of stress from sensor data. We find that during hours of day when craving is high, stress associated with self-reported high craving is greater than stress associated with low craving. We use this and other insights to develop feature functions, and encode them as pattern detectors in a Conditional Random Field (CRF) based model to infer craving probabilities.

1 September 2019 in Contemporary Clinical Trials Communications
Verified
Journal Article
Open access
AHAugust F. Holtyn
August F. Holtyn
EBEugene Bosworth
Eugene Bosworth
LMLisa A. Marsch
Lisa A. Marsch
BMBethany McLeman
Bethany McLeman
AMAndrea Meier
Andrea Meier
UGUdi E. Ghitza
Udi E. Ghitza
Cocaine use in clinical trials is often measured via self-report, which can be inaccurate, or urine drug screens, which can be intrusive and burdensome. Devices that can automatically detect cocaine use and can be worn conveniently in daily life may provide several benefits. AutoSense is a wearable, physiological-monitoring suite that can detect cocaine use, but it may be limited as a method for monitoring cocaine use because it requires wearing a chestband with electrodes. This paper describes the design, rationale, and methodology of a project that seeks to build upon and extend previous work in the development of methods to detect cocaine use via wearable, unobtrusive mobile sensor technologies. To this end, a wrist-worn sensor suite (i.e., MotionSense HRV) will be developed and evaluated. Participants who use cocaine (N = 25) will be asked to wear MotionSense HRV and AutoSense for two weeks during waking hours. Drug use will be assessed via thrice-weekly urine drug screens and self-reports, and will be used to isolate periods of cocaine use that will be differentiated from other drug use. The present study will provide information on the feasibility and acceptability of using a wrist-worn device to detect cocaine use.

7 March 2022 in IEEE Transactions on Signal Processing
Verified
Journal Article
Closed access
NSNithin Sugavanam
Nithin Sugavanam
SBSiddharth Baskar
Siddharth Baskar
EEEmre Ertin
Emre Ertin
We present a compressive radar design that combines multitone linear frequency modulated (LFM) waveforms in the transmitter with a classical stretch processor and sub-Nyquist sampling in the receiver. The proposed compressive illumination scheme has fewer random elements resulting in reduced storage and complexity for implementation and calibration than previously proposed compressive radar designs based on stochastic waveforms. We analyze this illumination scheme for the task of a joint range-angle of arrival estimation in the multi-input and multi-output (MIMO) radar system. We present recovery guarantees for the proposed illumination technique. We show that for a sufficiently large number of modulating tones, the system achieves high-resolution in range and successfully recovers the range and angle-of-arrival of targets in a sparse scene. Furthermore, we demonstrate the stability of recovery of targets in range and angle of arrival domain in the continuum. Finally, we present simulation results to illustrate the recovery performance as a function of system parameters.