Thomas Beuermann

Prof. Thomas Beuermann

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2017 in Bioprocess and Biosystems Engineering
Verified
Journal Article
Closed access
PDF file
RSRobert Schalk
Robert Schalk
FBFrank Braun
Frank Braun
RFRudolf Frank
Rudolf Frank
MRMatthias Rädle
Matthias Rädle
NGNorbert Gretz
Norbert Gretz
TBThomas Beuermann
Thomas Beuermann

17 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RSRobert Schalk
Robert Schalk
AHAnnabell Heintz
Annabell Heintz
FBFrank Braun
Frank Braun
GIGiuseppe Iacono
Giuseppe Iacono
Matthias RaedleMatthias Raedle
Matthias Raedle
TBThomas Beuermann
Thomas Beuermann
Raman and mid-infrared (MIR) spectroscopy are useful tools for the specific detection of molecules, since both methods are based on the excitation of fundamental vibration modes. In this study, Raman and MIR spectroscopy were applied simultaneously during aerobic yeast fermentations of Saccharomyces cerevisiae. Based on the recorded Raman intensities and MIR absorption spectra, respectively, temporal concentration courses of glucose, ethanol, and biomass were determined. The chemometric methods used to evaluate the analyte concentrations were partial least squares (PLS) regression and multiple linear regression (MLR). In view of potential photometric sensors, MLR models based on two (2D) and four (4D) analyte-specific optical channels were developed. All chemometric models were tested to predict glucose concentrations between 0 and 30 g L−1, ethanol concentrations between 0 and 10 g L−1, and biomass concentrations up to 15 g L−1 in real time during diauxic growth. Root-mean-squared errors of prediction (RMSEP) of 0.68 g L−1, 0.48 g L−1, and 0.37 g L−1 for glucose, ethanol, and biomass were achieved using the MIR setup combined with a PLS model. In the case of Raman spectroscopy, the corresponding RMSEP values were 0.92 g L−1, 0.39 g L−1, and 0.29 g L−1. Nevertheless, the simple 4D MLR models could reach the performance of the more complex PLS evaluation. Consequently, the replacement of spectrometer setups by four-channel sensors were discussed. Moreover, the advantages and disadvantages of Raman and MIR setups are demonstrated with regard to process implementation.

1 May 2017 in Journal of Bioscience and Bioengineering
Verified
Journal Article
Closed access
RSRobert Schalk
Robert Schalk
DGDaniel Geoerg
Daniel Geoerg
JSJens Staubach
Jens Staubach
MRMatthias Raedle
Matthias Raedle
FMFrank-Juergen Methner
Frank-Juergen Methner
TBThomas Beuermann
Thomas Beuermann

31 March 2012 in Journal of Bioscience and Bioengineering
Verified
Journal Article
Closed access
TBThomas Beuermann
Thomas Beuermann
DEDominik Egly
Dominik Egly
DGDaniel Geoerg
Daniel Geoerg
KKKerris Isolde Klug
Kerris Isolde Klug
WSWinfried Storhas
Winfried Storhas
FMFrank-Juergen Methner
Frank-Juergen Methner

23 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AHAnnabell Heintz
Annabell Heintz
SSSebastian Sold
Sebastian Sold
FWFelix Wühler
Felix Wühler
JDJulia Dyckow
Julia Dyckow
LSLucas Schirmer
Lucas Schirmer
Matthias RaedleMatthias Raedle
Matthias Raedle
Multimodal imaging gains increasing popularity for biomedical applications. This article presents the design of a novel multimodal imaging system. The centerpiece is a light microscope operating in the incident and transmitted light mode. Additionally, Raman spectroscopy and VIS/NIR reflectance spectroscopy are adapted. The proof-of-concept is realized to distinguish between grey matter (GM) and white matter (WM) of normal mouse brain tissue. Besides Raman and VIS/NIR spectroscopy, the following optical microscopy techniques are applied in the incident light mode: brightfield, darkfield, and polarization microscopy. To complement the study, brightfield images of a hematoxylin and eosin (H&E) stained cryosection in the transmitted light mode are recorded using the same imaging system. Data acquisition based on polarization microscopy and Raman spectroscopy gives the best results regarding the tissue differentiation of the unstained section. In addition to the discrimination of GM and WM, both modalities are suited to highlight differences in the density of myelinated axons. For Raman spectroscopy, this is achieved by calculating the sum of two intensity peak ratios (I2857 + I2888)/I2930 in the high-wavenumber region. For an optimum combination of the modalities, it is recommended to apply the molecule-specific but time-consuming Raman spectroscopy to smaller regions of interest, which have previously been identified by the microscopic modes.

8 February 2012 in Measurement Science and Technology
Verified
Journal Article
Closed access
DEDominik Egly
Dominik Egly
DGDaniel Geörg
Daniel Geörg
MRMatthias Rädle
Matthias Rädle
TBThomas Beuermann
Thomas Beuermann