Alberto De Stefani

Dr. Alberto De Stefani

Department of Neuroscience, University of Padua, 35122 Padova, PD, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
MBMartina Barone
Martina Barone
SASam Hatami Alamdari
Sam Hatami Alamdari
ABArjola Barjami
Arjola Barjami
UBUgo Baciliero
Ugo Baciliero
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
Aim: Three-dimensional facial imaging systems are a useful tool that is gradually replacing two-dimensional imaging and traditional anthropometry with calipers. In this varied and growing landscape of new devices, Canfield (Canfield Scientific, Parsippany, NJ, USA) has proposed a series of static and portable 3D imaging systems. The aim of this systematic review was to evaluate the current literature regarding the validation of Canfield’s Vectra imaging systems. Materials and Methods: A search strategy was developed on electronic databases including PubMed, Web of Science and Scopus by using specific keywords. After the study selection phase, a total of 10 articles were included in the present review. Results: A total of 10 articles were finally included in the present review. For six articles, we conducted a validation of the Vectra static devices, focusing especially on the Vectra M5, Vectra M3 and Vectra XT. For four articles, we validated the Vectra H1 portable system. Conclusions: All of the reviewed articles concluded that Canfield’s Vectra 3D imaging systems are capable of capturing accurate and reproducible stereophotogrammetric images. Minor errors were reported, particularly in the acquisition of the perioral region, but all the evaluated devices are considered to be valid and accurate tools for clinicians.

Alberto De StefaniAlberto De Stefani
Alberto De Stefani
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
SMSabrina Mutinelli
Sabrina Mutinelli
Antonio GraccoAntonio Gracco
Antonio Gracco
The aim of this study is an evaluation of the Italian dentists’ knowledge regarding COVID-19 and their perception of the risks associated with COVID-19, their attitude in resuming their activities, and how they judge the institutional intervention on a health and economic basis. Methods: This research evaluated Italian dentists from 11 to 18 April 2020, using a questionnaire submitted via Google Forms (Alphabet, Mountain View, CA, USA). It consisted of different investigations about sociodemographic aspects, profession-related characteristics, knowledge about COVID-19 infection transmission modalities, symptoms, and attitude in treating potentially infected patients. Statistical analysis was performed using the Pearson chi2 test and Student t-test. The α-level was fixed at p = 0.05. All data were analyzed with STATA 16 (StataCorp LP, College Station, TX, USA). Results: 1500 dentists (664 men and 836 women) completed the questionnaire. The majority of respondents declared having been trained in infection prevention procedures (64.3%) but not specifically to prevent the spread of COVID-19 (48.7%). A total of 57.2% declared that they were not trained sufficiently to restart working after lockdown, with a significantly higher prevalence (Pearson chi2 test, p < 0.001) among women (62.3%) than men (50.9%). Conclusion: Italian dentists were informed correctly on the mode of transmission but partially missed COVID-19 symptoms. Dentists considered the virus infection highly dangerous, and they were not confident in being able to work safely. The lack of precise operating guidelines creates uncertainties on infection control measures and appropriate personal protective equipment (PPE) use. The participants revealed apprehension for their health and the current and future economic situation of their practices.

9 November 2020 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
GPGiorgia Preo
Giorgia Preo
Antonio GraccoAntonio Gracco
Antonio Gracco
Nanotechnology refers to the science that manipulates matter at molecular and atomic levels, and studies matter at the nanoscale level to detect and exploit the useful properties that derive from these dimensions; materials with components less than 100 nm in at least one dimension are called nanomaterials. Nanotechnology is applied in many fields, such as medicine (nanomedicine) and dentistry (nano-dentistry). The purpose of these innovations and research in this field is to improve human life and health. This article aims to summarize and describe what the most recent and known innovations of nanotechnology in dentistry are, focusing on and paying particular attention to the branch that is orthodontics, and on the application of new nanomaterials in the realization, for example, of orthodontic elastomeric ligatures, orthodontic power chains, and orthodontic miniscrews. We also address a very important topic in orthodontics, which is how to reduce the friction force.

Antonio GraccoAntonio Gracco
Antonio Gracco
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
The advent of new technology has caused significant changes in the field of dentistry, enabling dentists and orthodontists to provide more efficient and effective treatments to their patients

16 May 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Antonio GraccoAntonio Gracco
Antonio Gracco
MDMartina Dandrea
Martina Dandrea
FDFlavio Deflorian
Flavio Deflorian
Caterina ZanellaCaterina Zanella
Caterina Zanella
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
ESEdoardo Stellini
Edoardo Stellini
Coatings incorporating nanoparticles of molybdenum and tungsten disulfide (MoS2 and WS2)—known for their lubricating properties—are applied to orthodontic stainless steel wires to verify if there is an improvement in terms of tribological properties during the sliding of the wire along the bracket. To simulate in vitro sliding of the wire along the bracket and evaluate friction 0.019 × 0.025 inches orthodontic stainless steel (SS) wires were subjected to the application, by electrodeposition, of Ni, Ni + MoS2, and Ni + WS2. The samples produced were analyzed with scanning electron microscopy and assessment of resistance to bending. Thirty-two test conditions have been analyzed, arising from the combination of four types of coatings (SS bare wires and strings with three types of coating), two types of self-ligating bracket (Damon Q, Ormco and In-Ovation R, GAC International), two bracket-wire angles (0° and 5°), two environments (dry and wet). Analyses carried out on the samples show acceptable coatings incorporating MoS2 and WS2 and a resistance of coatings after a minimum bending. In “dry conditions” a statistically significant decrease in friction occurs for wires coated with MoS2 and WS2 if associated with the In-Ovation bracket. In “wet conditions” this decrease is observed only in isolated test conditions. Analysis of the wires after sliding tests show little wear of the applied coatings. Nanoparticles are acceptable and similar in their behavior. Improvements in terms of friction are obtained pairing coatings incorporating MoS2 and WS2 with the In-Ovation bracket in dry conditions.

1 January 2017 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
GBG Bruno
G Bruno
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
PBPaolo Balasso
Paolo Balasso
SMS Mazzoleni
S Mazzoleni
AGA Gracco
A Gracco
The styloid process is a projecton of the temporal bone, its lenght is between 20 to 30 mm, when it is longer than 30 mm it is defined elongated styloid process. The aim of this study is an epidemiological evaluation of 1003 digital panoramic radiographs in an Italian population between 5 and 90 years old. This is a retrospective analysis and the radiographs were selected from the Complex Operating Unit of Dentistry of Padua University Hospital database. The radiographs were performed using a Sirona Ortophos XG and the styloid process length was measured using the measuring tool of Sidexis Software. It was measured from the point where it left the temporal bone plate to its tip. Styloid processes measuring more than 30 mm were considered elongated. Chi-squared test, Fligner-Killeen test, Shapiro-Wilk test and t-test with Welch correction were performed. In the study 33.40% of the patients showed an elongated styloid process. The number of patients with elongated styloid process and the mean length of the process increase with the age confirming the chronic development of the calcification described in literature. No statistically significant correlation is found between the presence of elongated styloid process and the gender and affected side (bilateral or unilateral). Key words:Elongated styloid process, panoramic radiograph, epidemiological study, Eagle's syndrome.