Shuzeng Zhang

Dr. Shuzeng Zhang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
GZGuangdong Zhang
Guangdong Zhang
XLXiongbing Li
Xiongbing Li
SZShuzeng Zhang
Shuzeng Zhang
TKTribikram Kundu
Tribikram Kundu
This work presents a peri-ultrasound theory based on ordinary state-based peridynamics for modeling elastic waves propagating in three-dimensional (3-D) plate structures and interacting with multiple cracks. A recently developed nonlinear ultrasonic technique called sideband peak count-index (or SPC-I) is adopted for monitoring one or more cracks with thickness values equal to 0 mm (crack-free), 1, 2, and 4 mm. Three separate scenarios—one crack, two cracks, and four cracks in 3-D plate structures—are investigated. These cracks can be classified as thin and thick cracks depending on the horizon size, which is mentioned in peri-ultrasound theory. Computed results for all three cases show larger SPC-I values for thin cracks than for thick cracks and the case of no cracks. This observation is in line with the previously reported results in the literature and proves that the state-based peri-ultrasound theory can capture the expected nonlinear response of elastic waves interacting with multiple cracks without changing the cracks' surface locations artificially, and this is always needed in most of the other numerical methods. The proposed state-based peri-ultrasound theory is more flexible and reliable for solving 3-D problems, and the out-of-plane wave field can be obtained for engineering analysis.

1 December 2021 in NDT & E International
Verified
Journal Article
Closed access
LQLiang Qin
Liang Qin
SZShuzeng Zhang
Shuzeng Zhang
YSYongfeng Song
Yongfeng Song
XLXiongbing Li
Xiongbing Li

6 September 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
GZGuangdong Zhang
Guangdong Zhang
XLXiling Liu
Xiling Liu
XLXiongbing Li
Xiongbing Li
YSYongfeng Song
Yongfeng Song
SZShuzeng Zhang
Shuzeng Zhang
Accurate measurements of the ultrasonic shear wave attenuation coefficient are essential for the quantitative nondestructive evaluation of the microstructure of a material. This work provides an experimental technique for measuring this coefficient using a contact method. The first and second pulse-echo shear wave signals are measured and are used to calculate the frequency-dependent attenuation coefficient; in this process, the diffraction and the diffraction-affected partial reflection coefficient are corrected to improve the accuracy of measurement. The diffraction coefficient is calculated from measurements of the shear wave velocity, and the partial reflection coefficient is determined experimentally by using another transducer on the opposite side and taking into account wave diffraction effects. The shear wave attenuation coefficient is determined for samples of different thicknesses, and these results show good agreement over a broadband frequency, thus validating the proposed method. The advantage of discriminating the porosity of additive manufacturing materials using shear wave attenuation is demonstrated, and the practical benefits of accurately measuring the shear wave attenuation coefficient using the proposed method are also discussed.

6 April 2024 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
MSMingzhu Sun
Mingzhu Sun
SZShuzeng Zhang
Shuzeng Zhang
GZGuangdong Zhang
Guangdong Zhang
XLXiongbing Li
Xiongbing Li
TKTribikram Kundu
Tribikram Kundu

17 May 2021 in Nondestructive Testing and Evaluation
Verified
Journal Article
Closed access
DLDuo Lyu
Duo Lyu
XLXiongbing Li
Xiongbing Li
RZRongfan Zhang
Rongfan Zhang
SZShuzeng Zhang
Shuzeng Zhang
The ultrasonic measurement model (UMM) has been theoretically studied over the past few decades, but there is little published work on its practical application for guiding defect detection. In this work, we present a model-based ultrasonic method to detect flaws in curved components using immersion of spherically focused transducers. The UMM of focused transducers is further investigated theoretically and verified experimentally, and some key issues in the model with focused transducers are addressed, including the necessity of correctly using effective geometrical parameters and the corresponding transfer function. The UMM is employed to guide the inspection of a magnesium alloy shell component which consists of several curved surfaces. The alignment between the transducer and the shell is conducted by comparing the measured and theoretically predicted interface-echo signals, the water path is selected by simulating the effective detection region, and the system gain is set by quantitatively analysing the amplitudes of flaw signals and noises. When the inspection conditions are determined, a variable threshold based on the predicted flaw signals is introduced to distinguish noise and flaw signals. The ultrasonic C-scan images of the shell are compared with the digital radiography (DR) images, and the comparison shows that the flaws of interest can be detected in the C-scan images, which verifies the effectiveness of the UMM-based detection method.

1 January 2021 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
SZShuzeng Zhang
Shuzeng Zhang
YHYunatian Huang
Yunatian Huang
XLXiongbing Li
Xiongbing Li
HJHyunjo Jeong
Hyunjo Jeong
The sound fields generated by ultrasonic transducers are modeled using the quasi-Monte Carlo (QMC) method, which is found to overcome the conflict between accuracy and efficiency that occurs in existing wave field calculation methods. The RI equation, which is frequently used as a model equation in ultrasonic field calculation, is used here as an exact method and for comparison purposes. In the QMC method, the judgment sampling method and Halton sequence are used for pseudo-random sampling from the sound source, and then the sound field distributions are found by solving the integral solution using the sample mean. Numerical examples and results are presented when modeling unfocused, focused, and steered and focused beam fields. The accuracy and efficiency of the QMC method are discussed by comparing the results obtained using different modeling methods. The results show that the proposed method has a high level of efficiency due to the nature of the QMC algorithm and a high level of accuracy because no approximation is required. In addition, wave fields can be modeled with the QMC method as long as sound sources can be effectively pseudo-randomly sampled, allowing the proposed method to be applied to various types of transducers.