Andrzej Ubysz

Prof. Dr. Andrzej Ubysz

Department of Building Structures, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
JKJeonghyun Kim
Jeonghyun Kim
Anna M. GrabiecAnna M. Grabiec
Anna M. Grabiec
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz
For complete utilization of construction and demolition (C&D) waste, an investigation of all size fractions of C&D waste generated during the recycling process should be conducted. In this work, the effects of three recycled concrete materials with different sizes (recycled coarse aggregate (RCA) with a size of 4.75–25 mm, recycled fine aggregate (RFA) of 0.15–4.75 mm, and recycled powder (RP) smaller than 0.15 mm) produced from concrete waste on the fresh and hardened mechanical properties of concrete were evaluated. The replacement ratios of natural coarse and fine aggregates by RCA and RFA were 30, 60, and 100%, and those of ordinary Portland cement for RP were 10, 20, and 30%. The results showed that the concrete properties deteriorated with increasing replacement ratio regardless of the type of recycled materials. The properties were reduced in the order of the use of RFA, RCA, and the simultaneous use of RCA and RFA. In addition, concrete with 30% RP showed lower mechanical strength than concrete with 100% RCA and 100% RFA. However, all concretes could be applicable for structural purposes under different environmental exposure conditions. In particular, concretes with 10% RP and 20% RP showed better cost-benefits compared to natural aggregate concrete with 100% ordinary Portland cement. These promising findings provide valuable initiatives for the effective and complete recycling of C&D waste.

29 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
JKJeonghyun Kim
Jeonghyun Kim
Anna M. GrabiecAnna M. Grabiec
Anna M. Grabiec
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz
SYSungchul Yang
Sungchul Yang
NKNamho Kim
Namho Kim
The decrease in the quality of recycled aggregate due to an increase in the number of recycling is a primary factor that limits the multi-recycling of concrete. This degradation adversely affects concrete performance; thus, the characteristics of recycled aggregate should be considered during the mix design stage, but little research has taken that into account. This study investigates the effect of the equivalent mortar volume (EMV) mix design on some physical, mechanical and durability properties of concrete made of multiple recycled coarse aggregates at 50% and 100% replacement ratios compared to concrete made by the conventional mix design (CMD). The results showed that the performances of concrete by the CMD decreased with an increasing number of recycling cycles. The properties of EMV-based concrete deteriorated with an increase in the number of recycling cycles at 100% replacement ratio due to poor workability caused by a shortage of fresh mortar. However, at 50% replacement, the EMV-based concrete exhibited similar performance across the three cycles of recycling, as well as improved properties over natural aggregate concrete. This study demonstrated that an appropriate mix design and optimal aggregate replacement ratio can offset the property loss of multiple recycled aggregate concrete.

24 June 2019 in Materials
Verified
Journal Article
Open access
PDF file
Marek MajMarek Maj
Marek Maj
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz
HHHala Hammadeh
Hala Hammadeh
FAFarzat Askifi
Farzat Askifi
Non-destructive tests of reinforced concrete chimneys, especially high ones, are an important element in assessing their condition, making it possible to forecast their safe life. Industrial chimneys are often exposed to the strong action of acidic substances, They are negatively exposed to the condensation of the flue gases. Condensate affects the inside of the thermal insulation and penetrates the chimney wall from the outside. This is one reason for the corrosion of concrete and reinforcing steel. Wet thermal insulation settles, and drastically reduces its insulating properties. This leads to an increase in temperature in the reinforced concrete chimney wall and creates additional large variations in temperature fields. This consequently causes a large increase in internal forces, which mainly increase tensile and shear stresses. This results in the appearance of additional cracks in the wall. The acid condensate penetrates these cracks, destroying the concrete cover and reinforcement. Thermographic studies are very helpful in monitoring the changes in temperature and consequently, the risk of concrete and reinforcement corrosion. This simple implication between changes in temperature of the chimney wall and increasing inner forces as shown in this article is particularly important when the chimney cannot be switched off due to the nature of the production process. Methods for interpreting the results of thermovision tests are presented to determine the safety and durability of industrial chimneys.

1 January 2021 in Materials Today: Proceedings
Verified
Journal Article
Closed access
TKTomasz Kowalik
Tomasz Kowalik
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz

12 July 2011 in JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT
Verified
Journal Article
Open access
MKMieczysław Kaminski
Mieczysław Kaminski
MMMichał Musiał
Michał Musiał
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz
The paper presents method of calculation of eigenfrequencies of the cracked reinforced concrete beams including discreet model of crack. The described method is based on the stiff finite elements method. It was modified in such a way as to take into account local discontinuities – cracks. In addition, some theoretical studies as well as experimental tests of concrete mechanics based on discrete crack model were taken into consideration. The calculations were performed using the author's own numerical algorithm. Moreover, other calculation methods of dynamic reinforced concrete beams presented in standards and guidelines are discussed. Calculations performed by using different methods are compared with the results obtained in experimental tests.

2 December 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Anna M. GrabiecAnna M. Grabiec
Anna M. Grabiec
JKJeonghyun Kim
Jeonghyun Kim
Andrzej UbyszAndrzej Ubysz
Andrzej Ubysz
PBPilar Bilbao
Pilar Bilbao
Research on recycled concrete aggregates (RCAs) has been progressively advanced. Beyond replacing natural aggregates with RCA, discussions have been held on the effect of the parent concrete and repeatedly recycled aggregate concrete. Although it has been reported that RCA can be technically used for structural concrete, due to several other factors, RCA is mainly used for sub-bases. Therefore, identifying these factors is the key to promoting the use of RCA. Therefore, this review study first briefly summarizes the physical and chemical characteristics of RCA compared to natural aggregate, and reviews the effects of parent concrete and repeatedly recycled aggregate on next generation concrete. This study also briefly discusses the RCA standards of various countries and the factors that hinder the widespread use of RCA. The results show that there is a correlation in properties between parent concrete and the next generation concrete, and the properties of concrete decrease when RCA is used repeatedly. In addition, on the basis of the literature review, factors hindering the use of RCA were found to be unstable supply and demand, economic feasibility, and negative perceptions.