The steel damper column is an energy-dissipating member that is suitable for reinforced concrete (RC) buildings and those used for multistory housing in particular. However, the effectiveness of steel damper columns may be affected by the behavior of surrounding members, and this effect can be severe in the case of seismic sequences. This article investigates the nonlinear response of building models with an RC moment-resisting frame (MRF) with and without steel damper columns under seismic sequences. The applicability of the concept of the momentary energy input to the prediction of the peak response of RC MRFs with damper columns under seismic sequences is also investigated. The main findings of the study are summarized as follows. (1) The peak response of RC MRFs with damper columns subjected to sequential accelerations is similar to the peak response obtained considering only the mainshock, whereas the cumulative strain energy of RC MRFs accumulates more for sequential accelerations. (2) The steel damper column is effective in reducing the peak and cumulative responses of RC MRFs in the case of sequential seismic input. (3) The relation of the hysteretic dissipated energy during a half cycle of the structural response and the peak displacement of the first modal response can be properly evaluated using the simple model proposed in this study.
A steel damper column is an energy-dissipating member that is suitable for reinforced concrete (RC) buildings and multistory housing. To assess the seismic performance of buildings with steel damper columns, the peak displacement of the whole building and the energy dissipation demand of the dampers must be evaluated. This article proposes an energy-based prediction procedure for the peak and cumulative response of an RC frame building with steel damper columns. The proposed procedure considers two energy-related seismic intensity parameters, namely the maximum momentary input energy and the total input energy. The peak displacement is predicted considering the energy balance during a half cycle of the structural response, using the maximum momentary input energy. The energy dissipation demand of the dampers is then predicted considering the energy balance during a whole response cycle using the total input energy. The local responses (e.g., peak drift, maximum plastic rotation of beams, maximum shear strain, and energy dissipation demand of dampers) are predicted using pushover analysis. Numerical analysis results for 8- and 16-story RC buildings show that the proposed prediction method achieves satisfactory accuracy.
5 January 2011 in Journal of Earthquake Engineering
The present article focuses on a nonlinear static procedure (NSP) for a multi-story asymmetric frame building with regular elevation subjected to bi-directional ground motion. In this procedure, two simplified models—an equivalent single-story model and an equivalent single-degree-of-freedom (SDOF) model—are used to predict the peak response of multi-story asymmetric buildings. The peak response is predicted through pushover analysis of an equivalent single-story model considering the effect of bi-directional excitations and an estimation of the nonlinear response of equivalent SDOF models. The predicted results are compared with the nonlinear dynamic analysis results, and satisfactory predictions can be obtained by the proposed procedure.
Steel damper columns (SDCs) are energy-dissipating members that are suitable for reinforced concrete (RC) buildings and are often used for multistory housing. The evaluation of the peak deformation and hysteretic dissipated energy of such building structures is essential for the rational seismic design of RC buildings with SDCs. In a previous study, the authors proposed an energy-based prediction procedure for the peak and cumulative response of an RC frame building with SDCs. In this procedure, the accuracy of the equivalent velocity of the maximum momentary input energy (VΔE1*)–peak equivalent displacement (D1*max) relationship is essential for high quality predictions. In this article, the VΔE1*–D1*max relationships of RC moment-resisting frames with and without SDCs are investigated using a critical pseudo-double impulse (PDI) analysis based on a study by Takewaki and coauthors. The results show that the VΔE1*–D1*max relationship obtained from the critical PDI analysis agrees well with that calculated from the equations proposed in the previous study.
Assessment of pushover-based method to a building with bidirectional setback asymmetric building;setback;pushover analysis;bidirectional excitation;torsional index;angle of incidence of seismic input; When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.