Yueh-Er Chiou

Prof. Yueh-Er Chiou

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WLWai-Hung Leung
Wai-Hung Leung
CPChi-Chia Pang
Chi-Chia Pang
SPSow-Neng Pang
Sow-Neng Pang
SWSheng-Xiang Weng
Sheng-Xiang Weng
YLYu-Lun Lin
Yu-Lun Lin
WWWen-Hui Weng
Wen-Hui Weng
The screening and diagnosis of cancer are hallmarks of medicine in the aging population. Recently, microRNAs have shown potential for use as biomarkers, which could advance the field of diagnostics. The presence of miRNA-141 in the serum has been well described in several malignancies. However, the invasive approach used for sampling represents the major limitation for its practical application and, hence, its notable absence as a method for screening the general population. In light of this, we aimed to develop a high-sensitivity microRNA (miR) biosensor for application in the diagnosis of all miR-141-associated cancers, such as colorectal cancer (CRC) and breast cancer (BC). The novelty lies in our dual-probe design, which is reliant on the hybridization of the fluorescein isothiocyanate (FITC) targeting probe onto an existing sample of urinary miR-141 in the first step, followed by complementary binding with a biotinylated probe that has been coated on a modified screen-printed carbon electrode (SPCE). The hybridization of the probe and sensor produces signals via the catalytic reduction of H2O2 at HRP-modified SPCEs in the presence of H2O, which was measured by either cyclic voltammetry or chronoamperometry (CA) currents. In our study, the detection and expression of miR-141 in a cohort of colorectal cancer (n = 6) and breast cancer (n = 4) samples showed that its levels were significantly higher than in a healthy cohort (n = 9) (p < 0.004). Moreover, our miR sensor demonstrated high stability, reliability, and sensitivity (p < 0.0001). This work hopefully provides new information for the detection and monitoring of de novo and existing cancers.

14 December 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
YCYueh-Er Chiou
Yueh-Er Chiou
KYKai-Jie Yu
Kai-Jie Yu
SPSow-Neng Pang
Sow-Neng Pang
YYYan-Lin Yang
Yan-Lin Yang
Jacob See-Tong Pang(Feng)Jacob See-Tong Pang(Feng)
Jacob See-Tong Pang(Feng)
WWWen-Hui Weng
Wen-Hui Weng
Prostate cancer is the most common cancer in the male population, carrying a significant disease burden. PSA is a widely available screening tools for this disease. Current screen-printed carbon electrode (SPCE)-based biosensors use a two-pronged probe approach to capture urinary miRNA. We were able to successfully detect specific exosomal miRNAs (exomiRs) in the urine of patients with prostate cancer, including exomiR-451 and exomiR-21, and used electrochemistry for measurement and analysis. Our results significantly reaffirmed the presence of exomiR-451 in urine and that a CV value higher than 220 nA is capable of identifying the presence of disease (p-value = 0.005). Similar results were further proven by a PAS greater than 4 (p-value = 0.001). Moreover, a higher urinary exomiR-21 was observed in the high-T3b stage; this significantly decreased following tumor removal (p-values were 0.016 and 0.907, respectively). According to analysis of the correlation with tumor metastasis, a higher exomiR-21 was associated with lymphatic metastasis (p-value 0.042), and higher exomiR-461 expression was correlated with tumor stage (p-value 0.031), demonstrating that the present exomiR biosensor can usefully predict tumor progression. In conclusion, this biosensor represents an easy-to-use, non-invasive screening tool that is both sensitive and specific. We strongly believe that this can be used in conjunction with PSA for the screening of prostate cancer.

17 June 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
SPSow-Neng Pang
Sow-Neng Pang
YLYu-Lun Lin
Yu-Lun Lin
YCYueh-Er Chiou
Yueh-Er Chiou
WLWai-Hung Leung
Wai-Hung Leung
WWWen-Hui Weng
Wen-Hui Weng
Research in cancer diagnostics has recently established its footing and significance in the biosensor sphere, emphasizing the idea of a unique probe design used as a sensor and actuator, to identify the presence of protein, DNA, RNA, or miRNA. The fluorescein isothiocyanate (FITC) probe and biotinylated probe are designed for a two-pronged approach to the detection of the urinary miR-21 and miR-141, both of which have demonstrated significance in the development and progression of colorectal cancer, a leading cause of mortality and morbidity. The remainder of the apparatus is composed of a modified screen-printed carbon electrode (SPCE), to which the probes adhere, that transduces signals via the redox reaction between H2O2 and HRP, measured with chronoamperometry and cyclic voltammetry. The precise nature of our ultra-non-invasive biosensor makes for a highly sensitive and practical cancer detector, concluded by the significance when establishing disease presence (miR-21 p-value = 0.0176, miR-141 p-value = 0.0032), disease follow-up (miR-21 p-value = 0.00154, miR141 p-value < 0.0005), and even disease severity. This article hopes to emphasize the potential of an additional clinical tool for the management of colorectal cancer.

7 December 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
SPSee-Tong Pang
See-Tong Pang
YCYueh-Er Chiou
Yueh-Er Chiou
JLjasmine Lim
jasmine Lim
YZYi-Chun Zhang
Yi-Chun Zhang
ZZZeng Wen Zhen
Zeng Wen Zhen
WWWen-Hui Weng
Wen-Hui Weng
In this study, we detected the expression levels of miR-21 in 38 clinical urine samples, obtained from 10 patients with PCa (with each sample obtained at three time points: before surgery, 1 month after surgery, and 3 months after surgery), 3 patients with benign prostatic hypertrophy (BPH), and 5 healthy subjects (as a control group). All of the samples were examined using a silver nanoparticle-based biosensor, and the sensitivity of the biosensor was simultaneously confirmed via qRT-PCR. The results were further analyzed together with clinical data such as PSA values and cancer stages. The sensitivity of the biosensor ranged up to 100 fM, and it presented a rather high selectivity rate. Our results indicated a significantly decreased expression level of miR-21 in the patient cases at 3 months post-surgery when compared with pre-surgery levels (p-value < 0.001). In addition, when distinguishing the differences in the expression level of miR-21 between healthy subjects and patients with PCa or BPH, both groups showed highly significant differences (p = 0.008 and p < 0.001, respectively). The results strongly suggest that the proposed miR-21 biosensor can be used as an auxiliary screening tool for the early detection of PCa and may effectively facilitate tracking of the progression of PCa, thus enabling more accurate healthcare decision making.

29 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
SPSow-Neng Pang
Sow-Neng Pang
YLYu-Lun Lin
Yu-Lun Lin
KYKai-Jie Yu
Kai-Jie Yu
YCYueh-Er Chiou
Yueh-Er Chiou
WLWai-Hung Leung
Wai-Hung Leung
WWWen-Hui Weng
Wen-Hui Weng
Due to the severe acute respiratory syndrome coronavirus (SARS-CoV-2, also called coronavirus disease 2019 (COVID-19)) pandemic starting in early 2020, all social activities ceased in order to combat its high transmission rate. Since vaccination combats one aspect for halting the spread of the virus, the biosensor community has looked at another aspect of reducing the burden of the COVID-19 pandemic on society by developing biosensors that incorporate point-of-care (POC) testing and the rapid identification of those affected in order to deploy appropriate measures. In this study, we aim first to propose a screen-printed carbon electrode (SPCE)-based electrochemical biosensor that meets the ASSURED criteria (i.e., affordable, sensitive, specific, user-friendly, rapid, equipment-free, and deliverable) for POC testing, but more importantly, we describe the novelty of our biosensor’s modifiability that uses custom dual probes made from target nucleic acid sequences. Additionally, regarding the sensitivity of the biosensor, the lowest sample concentration was 10 pM (p = 0.0257) without amplification, which might challenge the traditional technique of reverse transcriptase-polymerase chain reaction (RT-PCR). The purpose of this study is to develop a means of diagnostics for the current pandemic as well as to provide an established POC platform for future epidemics.

1 June 2020 in Neuropsychiatric Disease and Treatment
Verified
Journal Article
Open access
PDF file
YCYueh-Er Chiou
Yueh-Er Chiou
WCWu-Chien Chien
Wu-Chien Chien
CCChi-Hsiang Chung
Chi-Hsiang Chung
HCHsin-An Chang
Hsin-An Chang
YKYu-Chen Kao
Yu-Chen Kao
NTNian-Sheng Tzeng
Nian-Sheng Tzeng
Background: Herbal medicine containing aristolochic acids (HMCAA) was used for inflammatory and infectious diseases. This study aimed to investigate the association between the usage of HMCAA and the risk of dementia. Methods: A total of 199 new users of HMCAA were enrolled, along with 597 controls without the usage of HMCAA, at a ratio of 1:3 – matched by age, sex, and comorbidity, between 2000 and 2003 – from the National Health Research Institutes Database (NHRID) of Taiwan, which contains two million randomly sampled subjects, in this cohort study. We used Fine and Gray’s survival analysis (competing with mortality) to compare the risk of developing dementia during a 15-year follow-up period (2000– 2015). Results: In general, HMCAA was not significantly associated with dementia (adjusted subdistribution hazard ratio [SHR] = 0.861, 95% confidence interval [CI] = 0.484– 1.532, p = 0.611) for the HMCAA-cohort, although differential risk was observed among the groups at risk. The patients with usage of HMCAA aged ≧ 85 years were associated with a higher risk in dementia (adjusted SHR: 6.243, 95% CI=1.258– 21.084, p = 0.001), in comparison to those aged 50– 54 years. Furthermore, the patients with usage of HMCAA that had cerebrovascular accidents were associated with an increased risk of dementia. Conclusion: The usage of HMCAA was associated with the risk of developing dementia in the patients aged ≧ 85 years.