This article describes a method for estimating the temperature of high-power piezoelectric actuators when a direct temperature measurement is impractical. The heat flow is estimated from the real component of the electrical power; then, the temperature is estimated by a transfer function that approximates the thermal response of the system. The transfer function can be derived analytically from a lumped-element approximation or calibrated experimentally by using a system identification method. The proposed method is demonstrated on a piezoelectric stack actuator used in a high-speed nanopositioning device. A second-order transfer function estimates the temperature to within 3 $^{\circ }$ C of a reference measurement for a range of operating conditions. The proposed method is suitable for protecting piezoelectric actuators in applications where direct temperature measurement is impractical, for example, due to space or wiring constraints.
1 September 2017 in Review of Scientific Instruments
The performance of digital-to-analog converters is principally limited by errors in the output voltage levels. Such errors are known as element mismatch and are quantified by the integral non-linearity. Element mismatch limits the achievable accuracy and resolution in high-precision applications as it causes gain and offset errors, as well as harmonic distortion. In this article, five existing methods for mitigating the effects of element mismatch are compared: physical level calibration, dynamic element matching, noise-shaping with digital calibration, large periodic high-frequency dithering, and large stochastic high-pass dithering. These methods are suitable for improving accuracy when using digital-to-analog converters that use multiple discrete output levels to reconstruct time-varying signals. The methods improve linearity and therefore reduce harmonic distortion and can be retrofitted to existing systems with minor hardware variations. The performance of each method is compared theoretically and confirmed by simulations and experiments. Experimental results demonstrate that three of the five methods provide significant improvements in the resolution and accuracy when applied to a general-purpose digital-to-analog converter. As such, these methods can directly improve performance in a wide range of applications including nanopositioning, metrology, and optics.
5 March 2020 in IEEE Transactions on Signal Processing
Glitches introduce impulse-like disturbances which are not be readily attenuated by low-pass filtering. This article presents a model that describes the behaviour of glitches, and a method for mitigation based on a large-amplitude dither signal. Analytical and experimental results demonstrate that a dither signal with sufficient amplitude can mitigate the effect of glitches, when used in conjunction with a low-pass filter. The dither signal in conjunction with low-pass filtering essentially converts a glitch from a high-frequency to low-frequency disturbance.
Repetitive control (RC) is used to track and reject periodic exogenous signals. RC achieves tracking by incorporating a model of a periodic signal in the feedback path, which provides infinite loop-gain at the harmonic frequencies of the periodic signal. To improve robustness, the periodic signal model is bandwidth limited, and to improve the performance, an inverse plant response filter is used. This filter can either be an infinite impulse response (IIR) filter or a finite impulse response (FIR) filter. The accuracy of the filter typically determines the allowable bandwidth of the periodic signal model, and it is therefore desirable to obtain the most accurate inverse possible. In this paper a model-less method for synthesizing an FIR filter for the inverse response is presented, and it is compared to the common approach of using an inverse model-based IIR filter. An experimental comparison of the two approaches is presented, and it is demonstrated that the two methods produce identical results, but where the model-less FIR filter approach has the added benefit of avoiding the modeling effort needed to obtain the IIR filter.
An experimental assessment of some state-of-the-art commercially available digital-to-analog converters (DACs) is presented. A DAC is the principal enabling device for implementing modern digital feed-forward and feedback control. For precision mechatronic systems employing the best available instrumentation, the main limitation to resolution is presently the noise and distortion performance of DACs. The paper focuses on measuring the dynamic performance of the DACs, that is, the maximum resolution that can be achieved in practice when using the DACs for trajectory tracking, as well as the time-delay introduced due to DAC latency.
A transimpedance amplifier for use with a proposed ultra-linear current-output DAC was designed, implemented, and experimentally verified. The target precision was a signal-to-noise-and-distortion ratio (SINAD) of 122~dBFS, or 20 effective number of bits (ENOB), over a bandwidth of 100~kHz. Experimental verification was limited by the available measurement instrumentation, but the target was met.