Miranda Sertić

Dr. Miranda Sertić

Department of Pharmaceutical Analysis, University of Zagreb Faculty of Pharmacy and Biochemistry, 10000 Zagreb, Coratia
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


24 January 2013 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
Ana MornarAna Mornar
Ana Mornar
Miranda SertićMiranda Sertić
Miranda Sertić
BNBiljana Nigovic
Biljana Nigovic


16 May 2022 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
LTLu Turković
Lu Turković
LBLuka Bockor
Luka Bockor
OEOscar Ekpenyong
Oscar Ekpenyong
TSTajana Silovski
Tajana Silovski
MLMila Lovrić
Mila Lovrić
Miranda SertićMiranda Sertić
Miranda Sertić
Palbociclib, ribociclib and abemaciclib were recently approved as chemotherapeutic agents and are currently in the post-marketing surveillance phase. They are used in combination with aromatase inhibitors anastrozole and letrozole or antiestrogen fulvestrant for HR+, HER2− breast cancer treatment. Here, a novel bioanalytical LC-ESI-MS/MS method was developed for the quantitation of these six drugs in human plasma. The samples were prepared by simple protein precipitation followed by solvent evaporation. A Kinetex biphenyl column (150 × 4.6 mm, 2.6 µm) used for chromatographic analysis adequately resolved even the closely eluting aromatase inhibitors’ peaks. The mobile phase consisted of 0.1% formic acid in water and in ACN, in a linear gradient. An additional gradient step was added to eliminate the observed carry-over. The proposed method was fully validated in the relevant linear ranges covering the expected plasma concentrations of all six drugs (correlation coefficients between 0.9996 and 0.9931). The intra-day method precision (CV) ranged from 3.1% to 15%, while intra-day accuracy (%bias) was between −1.5% and 15.0%. The inter-day precision ranged from 1.6% to 14.9%, with accuracy between −14.3% and 14.6%, which is in accordance with the EMA and ICH guidelines on bioanalytical method validation. The method was successfully applied to samples from patients treated for HR+, HER2− breast cancer.

12 December 2020 in Indoor Air
Verified
Journal Article
Closed access
PDF file
DJDaniela Jakšić
Daniela Jakšić
Miranda SertićMiranda Sertić
Miranda Sertić
DKDomagoj Kifer
Domagoj Kifer
SKSandor Kocsubè
Sandor Kocsubè
Ana MornarAna Mornar
Ana Mornar
Maja Šegvić KlarićMaja Šegvić Klarić
Maja Šegvić Klarić